Youngjun Choi

Mr. Youngjun Choi


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SRSeungcheol Ryu
Seungcheol Ryu
CLChanghyung Lee
Changhyung Lee
YCYoungjun Choi
Youngjun Choi
KSKideok Sim
Kideok Sim
SHSeungyong Hahn
Seungyong Hahn
SKSeokho Kim
Seokho Kim
Recently, structural analysis related to stress and strain has become increasingly important in the design of high-field, high-temperature superconducting (HTS) magnets using Rare-Earth Barium Copper Oxide (REBCO) tapes. Superconducting magnets can be subjected to compressive loads due to various factors such as winding tension, Lorentz force, and thermal contraction. Deformation in superconducting magnets is typically predicted based on the material properties of REBCO tapes. However, the deformation behavior in the stacking direction under compressive stress conditions, influenced by uncertain contact conditions, continues to be an area of investigation. In this study, we measure and analyze the stress-strain characteristics of stacked REBCO tape under compression in the stacking direction to obtain a mechanical property. The experiments are conducted at room temperature using specimens with varying numbers of stacked layers, during which we measure displacement and deformation while gradually increasing the compressive stress up to 100 MPa. Additionally, consecutive three loading-unloading experiments are conducted to analyze the changes in stress and strain characteristics due to local plastic deformation. Furthermore, we employ a 3D laser microscope to measure the change of surface roughness. The stress-strain characteristics obtained from the experiments are expected to contribute to improving the accuracy of various high-magnetic field superconducting magnet designs.

30 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
YCYoungjun Choi
Youngjun Choi
DKDongmin Kim
Dongmin Kim
CLChanghyung Lee
Changhyung Lee
DWDuyeon Won
Duyeon Won
JYJaeun Yoo
Jaeun Yoo
SKSeokho Kim
Seokho Kim
Various high-temperature superconducting (HTS) power cables are being developed or are ready for commercial operation to help energy suppliers meet the growing power demand in urban areas. Recently, triaxial HTS power cables have been developed by Korea Electric Power Corporation (KEPCO) and LS Cable & System. Further, KEPCO has been planning to install a 2 km long 23 kV/60 MVA triaxial HTS power cable to connect the Munsan and Seonyu substations and increase the stability of the power grid. The HTS power cables should be cooled down to a cryogenic temperature near 77 K. A thermo-hydraulic analysis of the cooling system considering the geographical characteristics of the installation site is essential for long-distance sections. This paper describes the thermo-hydraulic analysis of the triaxial HTS power cable to determine the proper mass flow rates of subcooled liquid nitrogen that meet the operating temperature and pressure of the cable for four configurations of cooling systems: (1) a single cooling system with an external return path, (2) a dual cooling system with an external return path, (3) a single cooling system with an internal return path, and (4) a dual cooling system with internal return path. Since the flow characteristics in a corrugated cable cryostat differ significantly from those in a typical annular tube, a computational fluid dynamics (CFD) analysis was conducted to estimate the pressure drop along the cable cryostat. With the CFD analysis and given heat loads in the cable, the temperature and the pressure variations along the cable were calculated and their pros and cons were compared for each configuration of the cooling system. This thermo-hydraulic analysis will be referenced in the actual installation of the HTS power cable between the Munsan and Seonyu substations.

17 February 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YCYoungjun Choi
Youngjun Choi
DKDongmin Kim
Dongmin Kim
JCJeon-Wook Cho
Jeon-Wook Cho
SKSung-Kyu Kim
Sung-Kyu Kim
KSKideok Sim
Kideok Sim
SKSeokho Kim
Seokho Kim
The use of high temperature superconducting (HTS) power cables is viable solution to address the growing demand for electric power, while ensuring low loss and high electric power transmission. Usually, HTS power cables and circular connection of substations reduce grid impedance, and the fault current is increased over the capacity of the circuit breaker. To protect the electric power grid, the fault current should be reduced below the allowable level. Of late, research on HTS power cables having fault current limiting (FCL) functions has increased. An inductive FCL HTS power cable uses the increased inductive impedance caused by magnetic flux leakage to a neighboring iron yoke when a quench occurs at the shielding layer of the cable core due to electromagnetic coupling with the conducting layer. Therefore, there is less heat generation, and the temperature rise is suppressed. In this study, we describe the increased inductive impedance and reduced fault current using a FCL model coil. To demonstrate the electromagnetic coupling between the conducting and shielding layers of the cable core, two concentrically wound REBCO coils were fabricated. The iron yoke inside the coil increases the inductive impedance when a fault current flows through the conducting layer, and quench occurs at the shielding layer. The results are used to develop an FCL HTS power cable with 154 kV, 600 MVA class.

16 March 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YCYoungjun Choi
Youngjun Choi
SKSeokho Kim
Seokho Kim
The terminations of high-temperature superconducting (HTS) power cables help supply current between the cryogenic HTS power cable and the room temperature power system while maintaining electrical insulation. This involves a cryogenic section with circulating liquid nitrogen (LN 2 ) for cooling the HTS power cable and temperature gradient section with level interface formed by thermal equilibrium and an ambient section with current leads and insulation gases such as nitrogen and sulfur hexafluoride (SF 6 ). The level of LN 2 varies depending on the structure of the termination and the operation conditions, and this may further affect the temperature of the ambient section that is installed at the upper end of the cryogenic section. As the level of LN 2 increases, the temperature of the insulation gas decreases and condenses, resulting in a significant decrease in the dielectric strength. Therefore, it is crucial to estimate the level of LN 2 while designing the termination for HTS power cable. In this study, the LN 2 level of the termination was estimated according to heat load and the operating conditions to avoid dielectric breakdown of insulation gas are proposed using a commercial thermo-fluid network analysis tool, SINDA/FLUINT.

25 February 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SJSeungmin Jeon
Seungmin Jeon
YCYoungjun Choi
Youngjun Choi
JMJeongmin Mun
Jeongmin Mun
YKYonghyun Kwon
Yonghyun Kwon
SKSungrae Kim
Sungrae Kim
SKSeokho Kim
Seokho Kim
Quadrupole magnets located at the front end of an in-flight fragment (IF) separator in a heavy ion accelerator have large heat loads due to neutron radiation. Thus, high-temperature superconducting (HTS) magnets are used instead of low-temperature superconducting (LTS) magnets because of their high cooling efficiency and thermal stability. The cooling system of the HTS magnet uses circulation of cold helium gas. The circulating helium gas is provided from the distribution box, where helium gas lines are divided into 7 pairs of small helium lines corresponding to 7 HTS magnets. To cool down the 7 HTS magnets with different heat loads, the mass flow rate of each magnet should be individually controlled by monitoring the temperature of the magnets. This paper describes the cooling system for the 7 HTS magnets considering the heat load of each magnet and the thermohydraulic characteristics of the cooling system, including a heat exchanger, a cryogenic blower, control valves, etc. The helium mass flow rates for each magnet and the temperature at the outlet of the magnet are determined so that the magnets operate below 45 K. The optimal helium mass flow rates for each magnet were determined by analyzing the correlation between the magnet outlet temperature and flow rate.

3 April 2023 in Research Square
Verified
Preprint
Open access
PDF file
YCYoungjun Choi
Youngjun Choi
SKSeokho Kim
Seokho Kim
Recently, interest in renewable energy systems such as solar, hydrogen and wind power has increased as an alternative to fossil fuels. Renewable energy sources such as large wind and solar farms require long-distance power transmission because they are located inland or offshore, far from the city where power is required. High Temperature Superconducting (HTS) power cables have more than 5 times the transmission capacity and less than one-tenth the transmission loss compared to the existing cables of the same size, enabling large-capacity transmission at low voltage. In addition, it has perfect magnetic shielding performance, so it can fundamentally solve the electromagnetic wave environmental problem, and does not use any environmental pollutants in the existing high-voltage power cables. For commercialization of HTS power cables, unmanned operation and long-distance cooling technology of several kilometers is essential, and pressure drop characteristic is important. The cryostat's spiral corrugation tube is easier to bend, but unlike the round tube, the pressure drop cannot be calculated using the Moody chart. In addition, it is more difficult to predict the pressure drop characteristics due to the irregular surface roughness of the binder wound around the cable core. In this paper, a suitable CFD model of a spiral corrugation tube with a core was designed by referring to the water experiments from previous studies. In the four cases geometry, when the surface roughness of the core was 10mm, most errors were 15% and the maximum errors were 23%. These results will be used as a reference for the design of long-distance HTS power cables.