12 August 2020 in Superconductor Science and Technology
REBCO coated conductors are now being used for building very high-field magnets with large electromagnetic stresses, both expected ones due to transport current × stresses and additional stresses resulting from the large screening currents inherent in wide tapes. Post mortem analyses of several recent test coils operated above 40 T show that significant conductor plastic deformation occurs, even for JBR stresses well below the ∼1 GPa yield of the Hastelloy substrate of the conductor. To investigate these deformation mechanisms, conductors were unwound after coil test and carefully examined with respect to their length-wise
I
c
which revealed many areas of local damage. Regions of interest were examined by metallographic cross-section, Hall microscopy, magneto-optic imaging and scanning electronic microscopy. Important damage frequently occurred to the outer edges of pancakes in the coil ends, which were often plastically deformed over the whole turn circumference, especially when this outer edge was a slit edge. Internal conductor damage was also seen, especially delamination between the buffer and REBCO layers at slit edges. Careful sectioning of the tape at ∼10 mm intervals showed that the plastic deformation of the turns was complex and variable around the turn circumference, with tape cross-sections that exhibited continuous shape change in the outer turns. The bending center line of tapes often shifted from the tape center line toward the edge closest to the coil center, indicating asymmetric effects of transport and screening current stresses across the conductor width. A surprising and vital result is that damage was prevalent when the slit edge was also the edge at which transport current flowed. This damage was absent when the transport current flowed at the not-slit edge, implying great sensitivity of the effect of screening current stresses to localized conductor damage.
25 February 2019 in IEEE Transactions on Applied Superconductivity
We present assembly and test results of a 3-nested-coil 800-MHz (18.8 T) REBCO insert (H800) for the MIT 1.3 GHz LTS/HTS NMR magnet currently under completion. Each of the three H800 coils is a stack of no-insulation (NI) REBCO double-pancake coils (DPs). The innermost 8.7-T Coil 1 (26 DPs) was completed by mid-2016; the middle 5.6-T Coil 2 (32 DPs) was completed in mid-2017; while the outermost 4.5-T Coil 3 (38 DPs) was completed in early 2018. Coils 1, 2, and 3 were assembled together in early 2018 as a 3-nested-coil, the H800, and tested, first in liquid nitrogen to a power supply current of 20 A, followed by testing in liquid helium to a power supply current of 251.3 A, the H800's design operating current. After roughly five minutes settling time at 251.3 A, the H800 quenched. In this paper, we examine probable sources of quench initiation and simulate ensuing quench behavior. Remedial efforts to minimize the tendency toward quenching in the H800 are presented and discussed.
27 January 2020 in Superconductor Science and Technology
Present research on no-insulation (NI) rare earth barium copper oxide (REBCO) magnets have demonstrated their ability to produce high fields due to their compact nature. NI magnets have often been demonstrated to be self-protecting. However, evidence of mechanical damage in recent high field magnets, suggests that there are some issues about quench that must be resolved for this otherwise promising technology. This article attempts to explain multi-physics phenomena occurring during the quench of an NI magnet that can be used to elucidate quench behavior through experiments and simulations. A lumped circuit model is used for the circuit analysis where each coil is modeled as a single inductor with variable quench resistance in series and characteristic contact resistance in parallel. Three case studies have been analyzed: (1) a 3 double pancake (DP) standalone magnet, (2) a 2 DP coil in 31 T background, and (3) a high temperature superconductor/low temperature superconductor (HTS/LTS) hybrid user magnet that consists of a 13 T HTS insert and a 6 T LTS background magnet. Lessons learned from these analyses include: (1) characteristic resistance of NI coil rises during quench with the temperature rise; (2) influence of Hall effect exists on the voltage rise during quench; (3) over-current during quench can over-stress the coil; and (4) quench propagation from one end of the magnet generates significant unbalanced forces. This approach is expected to be used in the preliminary design of an ultra high field (>40 T) user magnet currently under design at the National High Magnetic Field Laboratory.
26 December 2011 in IEEE Transactions on Applied Superconductivity
This paper reports a study of two HTS racetrack coils wound with GdBCO coated conductors, one without turn-to-turn insulation and the other with Nomex insulation. The coils were characterized by charge-discharge, over-current, and sudden discharge tests. Thermal and electrical characteristics of the GdBCO racetrack coil without insulation outperformed the insulated one. The test results confirmed that although the coil without insulation has a slow charging/discharging time constant, the no-insulation winding technique may enable a compact and protection-free racetrack-typed coil with enhanced mechanical integrity as well as better thermal and electrical stabilities.
12 September 2017 in Superconductor Science and Technology
A conduction-cooled 3 T 100 mm winding bore multi-width and no-insulation (NI) all-REBCO magnet was designed, constructed and tested at 13 K. The magnet consists of a stack of double pancake (DP) coils wound with, for the first time, REBCO tapes having a 1 μm thick layer of stainless steel, named 'metallic cladding', that surrounds the tapes in a hermetic way to substantially reduce the NI charging delay. After construction, the magnet was cooled down to the target operating temperature of 13 K using a two-stage pulse-tube cryo-cooler. During charging–discharging tests up to 200 A, magnetic center field, voltage of each DP coil, power supply current, and magnet temperature were monitored. The charging time constant of the magnet was measured to be about 10.1 s, 13 times smaller than that of its NI counterpart. The magnet experienced, due to an unexpected power supply trip, a sudden discharge at a peak coil current density of 353 A mm2, yet it survived without any degradation. The results demonstrated strong potential of the metallic cladding NI-REBCO magnet for significant charging-delay reduction and self-protecting operation.
15 February 2017 in IEEE Transactions on Applied Superconductivity
Due to the self-protecting feature, no-insulation (NI) high-temperature superconductor magnets have been regarded as a reliable option to generate high fields, yet their intrinsic charging delay still remains a major drawback. To apply the NI technique for actual high-field user magnets, however, postquench transient behavior of such magnets need to be fully understood, particularly the electromagnetic interaction among magnetically coupled subcoils. Recent publications have shown successful simulations of the transient behavior of a single NI coil or a multicoil magnet using distributed network models. Even though these approaches are very accurate, they often require substantial computation time, especially when multiple iterations are required during design or analysis of an NI magnet having a large number of coils. This paper presents a simple circuit approach that may be effective for quench simulation of multicoil NI magnets. Each NI subcoil in a magnet is lumped into a single inductor with a resistor in series and a resistor in parallel. This approach has allowed us to simulate the whole magnet system within reasonable time without compromising the understanding of mutual interactions of all of the subcoils after quench, namely change in parameters such as voltage, current, and temperature with respect to time and coil to coil normal zone propagation in an electromagnetic manner. We verified the proposed approach by analyzing the quench process in a previously built 7 T, 78 mm all-REBCO NI magnet (by MIT), and by doing the first ever comparison between the simulated results with the data measured from actual experiment.