Tünde Kalmár

Dr. Tünde Kalmár


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2020 in Energies
Verified
Journal Article
Open access
PDF file
FKFerenc Kalmar
Ferenc Kalmar
TKTünde Kalmár
Tünde Kalmár
Glazing plays a key role in the energy balance of buildings. The aim of this paper is to enlighten the thermal discomfort caused by large glazed areas in the heating season and to point out a possible solution that can provide proper thermal comfort with low energy use. It is unusual to discuss the negative effects of solar gains on thermal comfort during the heating season. However, there are cases when glazing may lead to unforeseen indoor thermal discomfort conditions. Laboratory and on site measurements were performed in order to assess thermal discomfort caused by direct and diffuse radiation. It was shown that the WBGT (Wet Bulb Globe Temperature) index may exceed even 30 °C in the winter season in a room having large glazed area oriented to east. Laboratory tests performed in climate chamber have shown that the high PMV values cannot be reduced below 1.0, increasing the air change rate in the room. Using opaque drapes, the WBGT index was reduced by 2 °C, but the daylighting decreased substantially. It was demonstrated that by using advanced personalized ventilation systems, the appropriate thermal comfort can be provided avoiding the reduction of daylighting.

26 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
CICsáky Imre
Csáky Imre
TKTünde Kalmár
Tünde Kalmár
FKFerenc Kalmar
Ferenc Kalmar
Using personalized ventilation systems in office buildings, important energy saving might be obtained, which may improve the indoor air quality and thermal comfort sensation of occupants at the same time. In this paper, the operation testing results of an advanced personalized ventilation system are presented. Eleven different air terminal devices were analyzed. Based on the obtained air velocities and turbulence intensities, one was chosen to perform thermal comfort experiments with subjects. It was shown that, in the case of elevated indoor temperatures, the thermal comfort sensation can be improved considerably. A series of measurements were carried out in order to determine the background noise level and the noise generated by the personalized ventilation system. It was shown that further developments of the air distribution system are needed.

15 June 2024 in Buildings
Verified
Journal Article
Open access
PDF file
FKFerenc Kalmar
Ferenc Kalmar
BBBéla Bodó
Béla Bodó
BLBaizhan Li
Baizhan Li
TKTünde Kalmár
Tünde Kalmár
The main objectives of this study were the energy assessment of detached houses built in different periods in a central European city. A total of 236 detached houses built between 1930 and 2023 in Debrecen (Hungary) were analyzed from an energy perspective, and their CO2 emissions were measured. It was found that the net floor area of family houses built in recent years has increased but that the compactness of buildings has increased as well. The specific heat loss coefficient and the specific energy demand for heating in new buildings have decreased to 15.2% and 18.5%, respectively, over the last 90 years. Furthermore, around one third of the analyzed buildings built several decades ago must have already been renovated at least once for energy efficiency, as their heat demands are 27.6–41.4% lower than estimated. Energy consumption in six houses built in recent years was measured and studied. It was found that the occupants’ behavior may increase CO2 emissions from heating by 26%, while CO2 emissions from hot-water preparation may decrease by 38.2%. The potential of the locally available sources of renewable energy was calculated, and the costs of decarbonization packages for eight building groups were evaluated.

12 May 2025 in Buildings
Verified
Journal Article
Open access
PDF file
FKFerenc Kalmar
Ferenc Kalmar
BBBéla Bodó
Béla Bodó
TKTünde Kalmár
Tünde Kalmár
Mitigating carbon dioxide emissions in the building sector is a primary global goal. This paper compares different residential buildings in urban and rural regions of Hajdú-Bihar County (Hungary). Significant differences were found between urban and rural single-family houses concerning their energy performance; however, the differences in CO2 emissions were not significant. Only the differences in specific heat losses were significant between urban single-family and masonry-structured multifamily buildings. Panel buildings demonstrate the best energy performance from their construction period, but due to high investment costs and the inability to change the heat source, the CO2 emissions from these buildings have a lower limit today. In both single-family houses and masonry-structured multifamily buildings, meeting the heat demand can be achieved with zero CO2 emissions using existing technologies.

14 May 2026 in Buildings
Verified
Journal Article
Open access
PDF file
FKFerenc Kalmar
Ferenc Kalmar
SHSándor Hámori
Sándor Hámori
TKTünde Kalmár
Tünde Kalmár
Both developed and developing countries are striving to reduce building energy consumption. Heating still accounts for an important share of the total energy used in buildings. Many studies compare different heating modes, but few take into account that, first of all, in heated rooms, similar operative temperatures should be provided. In this study, operative temperatures in different locations of a heated room have been analysed, assuming two different heating systems. In addition, the operative temperature distribution can be further disturbed by the room geometry (one or more external walls, or family house) and the room’s position in the building (ground floor, intermediate floor, or top floor). The operative temperature distribution was analysed at nine locations across 525 different room models for radiator and floor heating. The conducted research proved that, at the p = 0.05 significance level, the differences in operative temperatures across locations in a radiator-heated room are significant. Differences in operative temperatures across locations in a floor-heated room are significant and the number of external walls (one, two, or three) also have a significant effect on operative temperatures in a heated room. The differences in operative temperatures at the same location in a heated room with different dimensions can be significant. The differences between the mean operative temperatures in a room (radiator-heated or floor-heated) are not significant if the room has different positions in a multilevel building (ground floor, intermediate level, or top level). To compare two heating systems energetically, a complex analysis should be conducted, and efforts should be made to ensure similar operative temperatures at the most critical locations.