As a result of COVID-19, many office buildings around the world have downsized their employees, but the comfort parameters in the building had to be kept. The facilities operation rearranged the workstations to keep physical distance and placed plexiglass sheets on the desks for physical protection. A series of measurements have been carried out with workstation set-ups to examine the fresh air rate in the occupied zone. The effect of plexiglass sheets placed on the desks was also examined to see how it changes the airflow pattern in the occupied zone. As the sheets act as a barrier, the primary air does not reach the occupied zone, therefore, the fresh air rate is less. To modify the properties of the ceiling diffusers a new air-ventilation service element was developed. This attachment allows modifying the properties of the ceiling diffusers. Simulations were made at the relevant zones to validate the measurements. Based on design software, the fresh air ratio for a standard ceiling swirl diffuser is 2.46 v% (volume percentage). A numerical model was used to show the fresh air ratio with the system elements for the two different table arrangements, which were 18.3 v% and 21.4 v%, respectively.
Previous studies have shown that the amount of energy consumed by mechanical cooling can be significantly reduced by the indirect evaporative cooling (IEC) process. By increasing the heat recovery efficiency of air handling units (AHUs), sensible cooling performance can be achieved with the IEC process for a significant part of the cooling season. This study determined the sensible cooling performance under which outdoor air conditions can be achieved. With IEC, the indoor humidity load cannot be adequately managed and must be solved by a supplementary cooling system, which may require additional cooling energy. This study shows the effect of the set indoor humidity on the amount of cooling energy required. The increase in energy consumption of the supplementary cooling system has been determined by simulation and for which indoor air conditions the amount of cooling energy used can be optimized if only IEC cooling is used in the air handling unit.
Using personalized ventilation systems in office buildings, important energy saving might be obtained, which may improve the indoor air quality and thermal comfort sensation of occupants at the same time. In this paper, the operation testing results of an advanced personalized ventilation system are presented. Eleven different air terminal devices were analyzed. Based on the obtained air velocities and turbulence intensities, one was chosen to perform thermal comfort experiments with subjects. It was shown that, in the case of elevated indoor temperatures, the thermal comfort sensation can be improved considerably. A series of measurements were carried out in order to determine the background noise level and the noise generated by the personalized ventilation system. It was shown that further developments of the air distribution system are needed.
Climate change has a potential impact on the number of hot and torrid days in the summer period. Due to the occupants’ comfort needs, and because of the high heat loads during the summer period, in several European countries, the energy used for air conditioning in buildings increased. With multiple environmental monitoring systems (Testo Saveris) in two similar offices, having west and east orientation of glazing, 1920 data (internal air, mean radiant temperature) related to operative temperature were collected in order to show the differences between heat loads of rooms with similar geometry in the same building. Data were measured in a 15 min interval. The diffuse and direct solar radiation had been determined for the horizontal and vertical surfaces, using the measured hourly global radiation (Debrecen, Hungary) data for the analyzed days (summer, hot, and torrid days). The local climatic results were compared with other climatic days used in different national standards. The daily energy need for cooling for different building comfort categories was also determined in the case of the representative days. The maximum daily energy need for cooling can be even 2.3 times higher for east orientation in comparison to the west orientation of the facades.
Using the personal ventilation systems may improve the thermal comfort sensation. At the University of Debrecen, a personal ventilation system was developed named ALTAIR. This paper presents the results of mean air velocity, turbulence grade, and draught measurements related to newly developed air terminal devices which are connected to the ALTAIR personal ventilation system. In order to define the measurement points it was essential to test the new air terminal devices (ATDs) in front of a black wall and smoke puffs. A series of measurements were carried out with isothermal air flow, mean air velocity, turbulence grade, and draught around the occupant head region in order to improve the thermal comfort sensation. Five different ATDs were analyzed.