Mona Fazel Ghaziyani

Mona Fazel Ghaziyani


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2020 in Radiology Research and Practice
Verified
Journal Article
Open access
PDF file
RSRamin Ghasemi Shayan
Ramin Ghasemi Shayan
MOMaryam Oladghaffari
Maryam Oladghaffari
FSFakhrosadat Sajjadian
Fakhrosadat Sajjadian
MGMona Fazel Ghaziyani
Mona Fazel Ghaziyani
CT and its comprehensive usage have become one of the most indispensable components in medical field especially in the diagnosis of several diseases. SECT and DECT have developed CT diagnostic potentials in several means. In this review article we have discussed the basic principles of single-energy and dual-energy computed tomography and their important physical differences which can cause better diagnostic evaluation. Moreover, different organs diagnostic evaluations through single-energy and dual-energy computed tomography have been discussed. Conventional or single-energy CT (SECT) uses a single polychromatic X-ray beam (ranging from 70 to 140 kVp with a standard of 120 kVp) emitted from a single source and received by a single detector. The concept of dual-energy computed tomography (DECT) is almost as old as the CT technology itself; DECT initially required substantially higher radiation doses (nearly two times higher than those employed in single-energy CT) and presented problems associated with spatial misregistration of the two different kV image datasets between the two separate acquisitions. The basic principles of single-energy and dual-energy computed tomography and their important physical differences can cause better diagnostic evaluation. Moreover, different organs diagnostic evaluations through single-energy and dual-energy computed tomography have been discussed. According to diverse data and statistics it is controversial to definitely indicate the accurate comparison of image quality and dose amount.

29 November 2018 in Advanced Pharmaceutical Bulletin
Verified
Journal Article
Open access
PDF file
MGMona Fazel Ghaziyani
Mona Fazel Ghaziyani
MMMohammd Pourhassan Moghaddam
Mohammd Pourhassan Moghaddam
Daryoush Shahbazi-GahroueiDaryoush Shahbazi-Gahrouei
Daryoush Shahbazi-Gahrouei
MGMostafa Ghavami
Mostafa Ghavami
AMAli Mohammadi
Ali Mohammadi
Behzad BaradaranBehzad Baradaran
Behzad Baradaran
Purpose: Molecular imaging is one of the import methods for recognition of cancer at the early stage in order to enhance the capacity of remedy. This study was aimed to introduce a new contrast agent that was targeted with CD24 so as to improve the CT scan detection of cancer cells with higher CD24 expression. Methods: The surface modifications of gold nanoparticles (Au-NPs) were done with long PEG (HS-PEG-CH3O) and short PEG (HS-PEG-COOH) chains to enhance their stability and capacity for immobilization of different antibodies. MTT assay was carried out to assess the biocompatibility of the NPs. The obtained contrast agent was implemented in the targeted CT imaging based on in vitro and in vivo studies of breast cancer. Results: The results revealed that the attached CD24 to the cell surface of PEGylated Au-NPs could enhance significantly the cells CT number (40.45 HU in 4T1, while it was 16.61 HU in CT26) It was shown that the attenuation coefficient of the molecularly targeted cells was more than 2 times excessive than the control groups. Further, the tumor region in model of xenograft tumor has higher density compare to the omnipaque groups, 60 min after injection (45 Hu vs.81 Hu). These results showed that the nanoparticles stayed in tumor region for longer time. Conclusion: It is predicted that the synthesized nanoparticle can be used as computed tomography contrast agent. Also, it can be used to identify the tumor cells with higher expression of CD24 at the early stages more efficiently compare to the other routine methods.

9 May 2023 in Egyptian Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
PDF file
AJAmirreza Jahanshahi
Amirreza Jahanshahi
YSYunus Soleymani
Yunus Soleymani
MGMona Fazel Ghaziyani
Mona Fazel Ghaziyani
DKDavood Khezerloo
Davood Khezerloo
Background: Radiomics has demonstrated striking potential in accurate cancer diagnosis but still needs strengthening of validity and standardization to achieve reproducible and generalizable results. Despite the advantages of radiomics, inter-scanner and intra-scanner variations of computed tomography (CT) scanning parameters can affect the reproducibility of its results. Accordingly, this article aims to review the impact of CT scanning parameters on the reproducibility of radiomics results. Main body of the In general, radiomics results are sensitive to changes in the noise level; therefore, any parameter that affects image noise, such as kilovoltage (kVp), tube current (mAs), slice thickness, spatial resolution, image reconstruction algorithm, etc., can affect radiomics results. Also, region of interest (ROI) segmentation is another fundamental challenge in reducing radiomics reproducibility. Studies showed that almost all scanning parameters affect the reproducibility of radiomics. However, some robust features are reproducible. Short conclusion: One of the solutions to overcome the radiomics reproducibility challenge is the standardization of imaging protocols according to noise level (not scanning protocols). The second solution is to list reproducible features according to the type of complication and anatomical region. Resampling may also overcome feature instability.


3 September 2021 in Egyptian Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
PDF file
YSYunus Soleymani
Yunus Soleymani
AJAmir Reza Jahanshahi
Amir Reza Jahanshahi
MHMaryam Hefzi
Maryam Hefzi
MGMona Fazel Ghaziyani
Mona Fazel Ghaziyani
APAmin Pourfarshid
Amin Pourfarshid
DKDavood Khezerloo
Davood Khezerloo
Background: The false-positive rate of computed tomography (CT) images in the diagnosis of coronavirus disease 2019 (COVID-19) is a challenge for the management in the pandemic. The main purpose of this study is to investigate the textural radiomics features on chest CT images of COVID-19 pneumonia patients and compare them with those of non-COVID pneumonia. This is a retrospective study. Some textural radiomics features were extracted from the CT images of 66 patients with COVID-19 pneumonia and 40 with non-COVID pneumonia. For radiomics analysis, the regions of interest (ROIs) were manually identified inside the pulmonary ground-glass opacities. For each ROI, 12 textural features were obtained and, then, statistical analysis was performed to assess the differences in these features between the two study groups. Results: 8 of the 12 texture features demonstrated a significant difference (P < 0.05) in two groups, with COVID-19 pneumonia lesions tending to be more heterogeneous in comparison with the non-COVID cases. Among the 8 significant features, only two (homogeneity and energy) were found to be higher in non-COVID cases. Conclusions: Textural radiomics features can be used for differentiating COVID-19 pneumonia from non-COVID pneumonia, as a non-invasive method, and help with better prognosis and diagnosis of COVID-19 patients.

11 August 2025 in Egyptian Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
PDF file
NSNesa Seify
Nesa Seify
DKDavood Khezerloo
Davood Khezerloo
AJAmir Reza Jahanshahi
Amir Reza Jahanshahi
MGMona Fazel Ghaziyani
Mona Fazel Ghaziyani
MRMelika Rahimiyan
Melika Rahimiyan
Background: Parkinson’s disease (PD) is the second most common neurological disorder, characterized by both motor and non-motor symptoms. Recent studies have shown that the nigrostriatal pathway undergoes changes as Parkinson's progresses. Radiomics, a quantitative image analysis technique, has recently gained attention in clinical issue. This longitudinal study aimed to evaluate radiomics features extracted from the bilateral caudate and putamen during Parkinson’s progression. Methods: Twenty PD and eighteen healthy control (HC) subjects with two-time-point MRI scans selected from Parkinson’s disease Progression Markers Initiative (PPMI) database, thirty-two features were extracted between the Parkinson's and healthy groups over two-year follow-up. Results: Among these thirty-two features, eighteen significant radiomics features (P < 0.05) between PD and HC groups showed meaningful alteration over two-year follow-up. The left caudate exhibited 12 significant features, surpassing the left/right putamen and right caudate, and its significance levels were also considerably higher [p-value = 0.001- 0.008]. Conclusion: Several radiomics features in the caudate and putamen change significantly during Parkinson's progression, specifically in the left caudate. Our features that based on a quantification of the pattern of gray level or gray-level runs of voxels, reflecting gray scale heterogeneity/uniformity, offer diagnostic information beyond naked eyes detection and may reflect pathophysiology. Radiomics textural changes in left caudate may reflect pathophysiology, serving as a noninvasive biomarker for disease management.