Background: Radiomics has demonstrated striking potential in accurate cancer diagnosis but still needs strengthening of validity and standardization to achieve reproducible and generalizable results. Despite the advantages of radiomics, inter-scanner and intra-scanner variations of computed tomography (CT) scanning parameters can affect the reproducibility of its results. Accordingly, this article aims to review the impact of CT scanning parameters on the reproducibility of radiomics results. Main body of the In general, radiomics results are sensitive to changes in the noise level; therefore, any parameter that affects image noise, such as kilovoltage (kVp), tube current (mAs), slice thickness, spatial resolution, image reconstruction algorithm, etc., can affect radiomics results. Also, region of interest (ROI) segmentation is another fundamental challenge in reducing radiomics reproducibility. Studies showed that almost all scanning parameters affect the reproducibility of radiomics. However, some robust features are reproducible. Short conclusion: One of the solutions to overcome the radiomics reproducibility challenge is the standardization of imaging protocols according to noise level (not scanning protocols). The second solution is to list reproducible features according to the type of complication and anatomical region. Resampling may also overcome feature instability.
Background: Nowadays, there has been a growing demand for low-dose computed tomography (LDCT) protocols. CT has a critical role in the management of the diagnosis chain of pulmonary disease, especially in lung cancer screening. There have been introduced several dose reduction methods, however, most of them are time-consuming, intricate, and vendor-based strategies that are hardly used in clinics routinely. This study aims to evaluate the image quality and pulmonary nodule detectability of LDCT protocols that are feasible and easy implemented. Image quality was analyzed in a general quality control phantom (Gammex) and then in a manmade lung phantom with nodules-equivalent objects. Methods: This study was designed in a two steps, in the first step, a feasible low-dose lung CT protocol was selected with quality assessment of accreditation phantom image. In the second step, the selected low-dose protocol with an appropriate image quality was performed on a manmade lung phantom in which there were objects equivalent to the pulmonary nodule. Finally, image quality parameters of the phantom at the appropriate scan protocol were compared with the standard protocol. Results: A reduction of about 17% of kVp and 46% in tube current leads to dose reduction by about 70%. The contrast-to-noise ratio in the low-dose protocol remained almost unchanged. The signal-to-noise ratio in the low-dose protocol decreased by approximately 32%, and the noise level has increased by about 1.5 times. However, this reduction method hardly affected the detectability of nodules in man-made pulmonary phantom. Conclusions: Here, we demonstrated that the LDCT scan has an insignificant effect on the perception of lung nodules. In this study, patient dose in lung CT was reduced by modifying of kVp and mAs about approximately 70%. Hence, to step in toward low-dose strategies in medical imaging clinics, using easy-implemented and feasible low-dose strategies may be helpful.
3 September 2021 in Egyptian Journal of Radiology and Nuclear Medicine
Background: The false-positive rate of computed tomography (CT) images in the diagnosis of coronavirus disease 2019 (COVID-19) is a challenge for the management in the pandemic. The main purpose of this study is to investigate the textural radiomics features on chest CT images of COVID-19 pneumonia patients and compare them with those of non-COVID pneumonia. This is a retrospective study. Some textural radiomics features were extracted from the CT images of 66 patients with COVID-19 pneumonia and 40 with non-COVID pneumonia. For radiomics analysis, the regions of interest (ROIs) were manually identified inside the pulmonary ground-glass opacities. For each ROI, 12 textural features were obtained and, then, statistical analysis was performed to assess the differences in these features between the two study groups. Results: 8 of the 12 texture features demonstrated a significant difference (P < 0.05) in two groups, with COVID-19 pneumonia lesions tending to be more heterogeneous in comparison with the non-COVID cases. Among the 8 significant features, only two (homogeneity and energy) were found to be higher in non-COVID cases. Conclusions: Textural radiomics features can be used for differentiating COVID-19 pneumonia from non-COVID pneumonia, as a non-invasive method, and help with better prognosis and diagnosis of COVID-19 patients.