Mamadou Lamine Doumbia

Prof. Dr. Mamadou Lamine Doumbia

Department of Electrical and Computer Engineering, Université du Québec à Trois-Rivières, 3351 Boulevard des Forges, Trois-Rivières, QC G9A 5H7, Canada

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
JEJunior Diamant Ngando Ebba
Junior Diamant Ngando Ebba
Mamadou Baïlo CamaraMamadou Baïlo Camara
Mamadou Baïlo Camara
Mamadou Lamine DoumbiaMamadou Lamine Doumbia
Mamadou Lamine Doumbia
Brayima DakyoBrayima Dakyo
Brayima Dakyo
JSJoseph Song-Manguelle
Joseph Song-Manguelle
To achieve a more ecologically friendly energy transition by the year 2050 under the European “green” accord, hydrogen has recently gained significant scientific interest due to its efficiency as an energy carrier. This paper focuses on large-scale hydrogen production systems based on marine renewable-energy-based wind turbines and tidal turbines. The paper reviews the different technologies of hydrogen production using water electrolyzers, energy storage unit base hydrogen vectors, and fuel cells (FC). The focus is on large-scale hydrogen production systems using marine renewable energies. This study compares electrolyzers, energy storage units, and FC technologies, with the main factors considered being cost, sustainability, and efficiency. Furthermore, a review of aging models of electrolyzers and FCs based on electrical circuit models is drawn from the literature and presented, including characterization methods of the model components and the parameters extraction methods, using a dynamic current profile. In addition, industrial projects for producing hydrogen from renewable energies that have already been completed or are now in progress are examined. The paper is concluded through a summary of recent hydrogen production and energy storage advances, as well as some applications. Perspectives on enhancing the sustainability and efficiency of hydrogen production systems are also proposed and discussed. This paper provides a review of behavioral aging models of electrolyzers and FCs when integrated into hydrogen production systems, as this is crucial for their successful deployment in an ever-changing energy context. We also review the EU’s potential for renewable energy analysis. In summary, this study provides valuable information for research and industry stakeholders aiming to promote a sustainable and environmentally friendly energy transition.

9 December 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
PLPascal LINGOM
Pascal LINGOM
JSJoseph Song-Manguelle
Joseph Song-Manguelle
Mamadou Lamine DoumbiaMamadou Lamine Doumbia
Mamadou Lamine Doumbia
RFRodolfo C. C. Flesch
Rodolfo C. C. Flesch
TJTao Jin
Tao Jin
This article proposes a high-level engineering guide to develop an integrated system model for power quality analysis in electrical submersible pump (ESP) applications with variable frequency drives (VFDs). Such analyses are troublesome in the industry due to the complexity of these systems. In this article, simple steps to perform system integration analyses of such arrangements, including torsional analysis, are developed. A simplified VFD-ESP model suitable for coupled electrical and mechanical analysis in steady state is proposed in all their configurations of practical interest. Such a model can be easily implemented in common simulation software, significantly reducing engineering efforts for implementation and analysis. The focus of the proposed model is the prediction of ESP failures that might result from a poor power quality caused by VFDs. Analytical expressions of different types of harmonics in these systems, as well as their accurate locations in the frequency domain, including their interharmonics and common-mode harmonics, are derived for this purpose. The effectiveness of the proposed model is verified through offline and real-time hybrid simulation results. Finally, a comparison between simulation results obtained using the proposed model and measurements collected on a down-scale laboratory prototype is carried out to demonstrate the accuracy of the suggested modeling approach.

2 February 2024 in Energies
Verified
Journal Article
Open access
PDF file
PLPascal LINGOM
Pascal LINGOM
JSJoseph Song-Manguelle
Joseph Song-Manguelle
JNJean Maurice Nyobe-Yome
Jean Maurice Nyobe-Yome
Mamadou Lamine DoumbiaMamadou Lamine Doumbia
Mamadou Lamine Doumbia
A cascaded H-bridge multilevel converter topology is the ultimate solution for energy conversion in various industrial applications due to its exceptional features, such as high modularity and fault-tolerant capability. However, two circumstances can lead to unbalanced operation of the inverter, potentially causing a decrease in its reliability and survivability: unequal DC voltage sources and faulty cells. In recent decades, scientists and engineers have conducted intensive research and meaningful studies to propose control solutions capable of maintaining the stable and continuous operation of the inverter under these operational concerns. Typically, each challenge is addressed separately using a distinct compensation control scheme in the existing literature. The paper aims to offer a comprehensive review of the existing compensation control schemes appropriate for CHBMIs operating under unbalanced conditions. It overviews the most popular control schemes and summarizes their usefulness in such scenarios. The theoretical foundations of each control scheme are presented and discussed, including their operating principles, implementation schemes, advantages, and disadvantages. The paper concludes with suggested future trends that require further research for CHBMIs’ continued growth and adoption in various industrial applications.

11 December 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DMDaniel Legrand Mon-Nzongo
Daniel Legrand Mon-Nzongo
GEGabriel Ekemb
Gabriel Ekemb
JSJoseph Song-Manguelle
Joseph Song-Manguelle
PIPaul Gistain Ipoum-Ngome
Paul Gistain Ipoum-Ngome
TJTao Jin
Tao Jin
Mamadou Lamine DoumbiaMamadou Lamine Doumbia
Mamadou Lamine Doumbia
This paper proposes an analytical time and frequency domains evaluation of torque harmonics produced by high-power Load-Commutated-Inverters (LCIs) and Pulse-Width-Modulated (PWM) Voltage Source Inverters (VSIs) for adjustable speed applications. These drive systems are used in petrochemical and mining industries where driven loads have multi-inertia or long shafts that are potentially subject to torsional mode excitation. Such excitation may lead to accelerated fatigue, system failure, and loss of production, and in turbine-generator sets, to system blackout. The investigated power conversion topologies are multi-pulse LCIs (6/6 and 12/12-pulse systems), parallel connected three-level neutral-clamped-converters with non-interleaved and interleaved PWM signals, as well as series-connected H-bridge multilevel inverters, single thread and four threads supplying a 12-phase machine and parallel connection of four threads converter systems with interleaved PWM commands. They are the most used variable frequency drives in the megawatt range, both with synchronous and induction machines, in the petrochemical industry. The time and frequency domains of the machine's air-gap torque is calculated from the motor's voltage and stator's current waveforms, this proven method is independent from the type of AC machine. More than 50 simulated operating points are discussed and experimental results for NPC and cascaded inverters are also presented.

2 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
PLPascal LINGOM
Pascal LINGOM
JSJoseph Song-Manguelle
Joseph Song-Manguelle
SBSimon Pierre Betoka-Onyama
Simon Pierre Betoka-Onyama
JNJean Maurice Nyobe-Yome
Jean Maurice Nyobe-Yome
Mamadou Lamine DoumbiaMamadou Lamine Doumbia
Mamadou Lamine Doumbia
This paper proposed a simplified modeling approach for a power quality (PQ) assessment of Electric Submersible Pumps (ESP) systems supplied by the two-level, the neutral-point-clamped three-level, and the cascaded H-bridge (CHB) multilevel inverter VFD topologies. The VFD switching function models and their analytical expressions are proposed to understand how they can create high-frequency components that might excite the resonance mode in a transmission cable or a rotating shaft system. Voltage, current, and motor airgap torque harmonics induced by each VFD topology in a balanced operation mode are derived and correlated to the PWM carrier and motor operating frequencies. The motor airgap harmonics are calculated based on Concordia’s transformation of voltages and currents in αβ-plan. These harmonic components are represented in the form of Campbell diagrams. An analysis of harmonics under unbalanced conditions was also conducted in a CHB VFD topology-powered ESP system with failed and bypassed cells. The investigated modulation technique is a neutral-shift PWM method that enables the system to operate balanced line-line voltages even if the line-neutral voltages are unbalanced. The effects of modifying the electrical spectrum using the neutral-shift PWM method on electrical and mechanical spectra are analyzed. The results of the Matlab/Simulink-based simulation show that the proposed full ESP system model is highly accurate in both normal and failure modes. The results are consistent with theoretical predictions and are graphically shown in the time and frequency domains for easy analysis. Hybrid experimental–numerical results on a reduced-scale laboratory setup are also discussed to confirm the correctness of the suggested developments.

3 February 2016 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
Hicham ChaouiHicham Chaoui
Hicham Chaoui
BHBekhada Hamane
Bekhada Hamane
Mamadou Lamine DoumbiaMamadou Lamine Doumbia
Mamadou Lamine Doumbia