Tamaki Nakano

Dr. Tamaki Nakano

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2021 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
YCYuming Chen
Yuming Chen
ZZZhihao Zhai
Zhihao Zhai
HLHefei Li
Hefei Li
SYShuhei Yamada
Shuhei Yamada
TMTakashi Matsuoka
Takashi Matsuoka
TNTamaki Nakano
Tamaki Nakano

8 July 2022 in Journal of Dentistry
Verified
Journal Article
Closed access
YCYuming Chen
Yuming Chen
ZZZhihao Zhai
Zhihao Zhai
SWShota Watanabe
Shota Watanabe
TNTamaki Nakano
Tamaki Nakano
SIShoichi Ishigaki
Shoichi Ishigaki

29 January 2020 in International Journal of Implant Dentistry
Verified
Journal Article
Open access
PDF file
HAHaruka Araki
Haruka Araki
TNTamaki Nakano
Tamaki Nakano
SOShinji Ono
Shinji Ono
HYHirofumi Yatani
Hirofumi Yatani
Aim: When using short implants, fracture of the implant body and bone resorption are a concern because stress concentrates on and around a short implant. The purpose of this research is to investigate the differences in stress distribution between tissue level (TL) and bone level (BL) implant body designs, and between commercially pure titanium (cpTi) and the newer titanium–zirconium (TiZr) alloy in using short implants. Materials and methods: Models of TL and BL implants were prepared for three-dimensional finite element analysis. The implants were produced in 10 mm, 8 mm, and 6 mm lengths, and the TL was also produced in a 4-mm length. A static load of 100 N inclined at 30° to the long axis was applied to the buccal side of the model. The largest maximum principal stress value in the cortical bone and the largest von Mises stress value in the implant body were evaluated. Results: Stress concentration was observed at the connection part of the implant, especially above the bone in TL and within the bone in BL. In the TL design, tensile stress occurred on the buccal side and compressive stress on the lingual side of the cortical bone. Conversely, in the BL design, tensile stress occurred on the lingual side of the cortical bone. CpTi and TiZr showed a similar stress distribution pattern. The maximum stress values were lower in the TL design than the BL design, and they were lower with TiZr than cpTi for both the cortical bone and implant body. The maximum value tended to increase as the length of the implant body decreased. In addition, the implant body design was more influential than its length, with the TL design showing a stress value similar to the longer BL design. Conclusion: Using TiZr and a TL design may be more useful mechanically than cpTi and a BL design when the length of the implant body must be shorter because of insufficient vertical bone mass in the mandible.

23 December 2014 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
AKAkihiro Kaminaka
Akihiro Kaminaka
TNTamaki Nakano
Tamaki Nakano
SOShinji Ono
Shinji Ono
TKTokinori Kato
Tokinori Kato
HYHirofumi Yatani
Hirofumi Yatani

11 November 2020 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
MIMasaki Inoue
Masaki Inoue
TNTamaki Nakano
Tamaki Nakano
TSTakuya Shimomoto
Takuya Shimomoto
DKDaijiro Kabata
Daijiro Kabata
ASAyumi Shintani
Ayumi Shintani
HYHirofumi Yatani
Hirofumi Yatani

22 July 2023 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
YCYuming Chen
Yuming Chen
HLHefei Li
Hefei Li
ZZZhihao Zhai
Zhihao Zhai
TNTamaki Nakano
Tamaki Nakano
SIShoichi Ishigaki
Shoichi Ishigaki