Zhihao Zhai

Zhihao Zhai

Auto-generated profile, based on publicly available information

Zhihao Zhai

Department of Regenerative Prosthodontics, Graduate School of Dentistry, The University of Osaka, Osaka, Japan

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2022 in Journal of Dentistry
Verified
Journal Article
Closed access
YCYuming Chen
Yuming Chen
ZZZhihao Zhai
Zhihao Zhai
SWShota Watanabe
Shota Watanabe
TNTamaki Nakano
Tamaki Nakano
SIShoichi Ishigaki
Shoichi Ishigaki

22 November 2022 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
ZZZhihao Zhai
Zhihao Zhai
TNTamaki Nakano
Tamaki Nakano
YCYuming Chen
Yuming Chen
SWShota Watanabe
Shota Watanabe
TMTakashi Matsuoka
Takashi Matsuoka
SIShoichi Ishigaki
Shoichi Ishigaki

16 December 2022 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
ZZZhihao Zhai
Zhihao Zhai
TNTamaki Nakano
Tamaki Nakano
YCYuming Chen
Yuming Chen
SWShota Watanabe
Shota Watanabe
TMTakashi Matsuoka
Takashi Matsuoka
SIShoichi Ishigaki
Shoichi Ishigaki

16 July 2026 in International Dental Journal
Verified
Journal Article
Open access
YCYuming Chen
Yuming Chen
HLHefei Li
Hefei Li
ZZZhihao Zhai
Zhihao Zhai
ZGZiyu Ge
Ziyu Ge
YZYanzhen Zhang
Yanzhen Zhang
Accurate, stable 3D-printed models are essential for digital dental workflows. This study evaluated the effects of storage time, internal design and printing workflows on the dimensional stability and accuracy of dental models. A maxillary typodont was scanned to generate a reference digital model. Three internal designs were created: hollow with perforated base (HB), solid (S) and support structure with perforated base (SB). Sixty models fabricated via Form 3 (SLA) and Straumann P30+ (DLP) printers were stored under controlled indoor conditions and scanned at 7 time points within 4 weeks. Geomagic Control software analysed accuracy (trueness/precision via best-fit alignment and root mean square [RMS] values) and volume. For the DLP workflow, trueness and volume significantly changed over time (P < .001). Trueness decreased after 2 weeks for S and SB and after 3 weeks for HB. Volume decreased after 1 week for all designs. Precision showed no significant changes. Volume was negatively correlated with trueness (RMS values) and storage time, while storage time positively correlated with trueness (RMS values) (all P < .001). Conversely, models printed by the SLA workflow showed no significant changes in trueness, precision, or volume over 4 weeks, demonstrating significantly higher stability than that of the DLP workflow (P < .001). Internal design had no significant effect. Storage time significantly affects trueness in the evaluated DLP workflow, with volumetric shrinkage being a highly probable contributing factor, whereas models printed by the SLA workflow remain stable for up to 4 weeks. Internal design showed no significant dimensional effect. Variations across specific printing workflows may influence the dimensional stability of dental models. To ensure accuracy, models from the evaluated DLP workflow require use within 2 weeks, whereas the tested SLA workflow is recommended for applications requiring storage or transportation.

3 November 2026 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
RTRyota Takaoka
Ryota Takaoka
ZZZhihao Zhai
Zhihao Zhai
SMShion Morioka
Shion Morioka
KNKenichi Nomura
Kenichi Nomura
YTYohei Tsuneto
Yohei Tsuneto
MNMasahiro Nishimura
Masahiro Nishimura