Tropospheric vertical column densities (VCDs) of NO2, SO2 and HCHO derived from the Ozone Monitoring Instrument (OMI) on AURA and the Global Ozone Monitoring Experiment 2 aboard METOP-A (GOME-2A) and METOP-B (GOME-2B) are widely used to characterize the global distributions, trends and dominating sources of these trace gases. They are also useful for the comparison with chemical transport models (CTMs). We use tropospheric VCDs and vertical profiles of NO2, SO2 and HCHO derived from MAX-DOAS measurements from 2011 to 2014 in Wuxi, China, to validate the corresponding products (daily and bi-monthly-averaged data) derived from OMI and GOME-2A/B by different scientific teams. Prior to the comparison, the spatial and temporal coincidence criteria for MAX-DOAS and satellite data are determined by a sensitivity study using different spatial and temporal averaging conditions. Cloud effects on both MAX-DOAS and satellite observations are also investigated. Our results indicate that the discrepancies between satellite and MAX-DOAS results increase with increasing effective cloud fraction and are dominated by the effects of clouds on the satellite products. In comparison with MAX-DOAS, we found a systematic underestimation of all SO2 (40 to 57 %) and HCHO products (about 20 %), and an overestimation of the GOME-2A/B NO2 products (about 30 %), but good consistency with the DOMINO version 2 NO2 product. To better understand the reasons for these differences, we evaluated the a priori profile shapes used in the OMI retrievals (derived from CTM) by comparison with those derived from the MAX-DOAS observations. Significant differences are found for the SO2 and HCHO profile shapes derived from the IMAGES model, whereas on average good agreement is found for the NO2 profile shapes derived from the TM4 model. We also applied the MAX-DOAS profile shapes to the satellite retrievals and found that these modified satellite VCDs agree better with the MAX-DOAS VCDs than the VCDs from the original data sets by up to 10, 47 and 35 % for NO2, SO2 and HCHO, respectively. Furthermore, we investigated the effect of aerosols on the satellite retrievals. For OMI observations of NO2, a systematic underestimation is found for large AOD, which is mainly attributed to effect of the aerosols on the cloud retrieval and the subsequent application of a cloud correction scheme (implicit aerosol correction). In contrast, the effect of aerosols on the clear-sky air mass factor (explicit aerosol correction) has a smaller effect. For SO2 and HCHO observations selected in the same way, no clear aerosol effect is found, probably because for the considered data sets no cloud correction is applied (and also because of the larger scatter). From our findings we conclude that for satellite observations with cloud top pressure (CTP) > 900 hPa and effective cloud fraction (eCF) < 10 % the application of a clear-sky air mass factor might be a good option if accurate aerosol information is not available. Another finding of our study is that the ratio of morning-to-afternoon NO2 VCDs can be considerably overestimated if results from different sensors and/or retrievals (e.g. OMI and GOME-2) are used, whereas fewer deviations for HCHO and SO2 VCDs are found.
24 May 2022 in Journal of Geophysical Research: Atmospheres
In order to promote the development of the passive DOAS technique the Multi Axis DOAS – Comparison campaign for Aerosols and Trace gases (MAD-CAT) was held at the Max Planck Institute for Chemistry in Mainz, Germany, from June to October 2013. Here, we systematically compare the differential slant column densities (dSCDs) of nitrous acid (HONO) derived from measurements of seven different instruments. We also compare the tropospheric difference of SCDs (delta SCD) of HONO, namely the difference of the SCDs for the non-zenith observations and the zenith observation of the same elevation sequence. Different research groups analysed the spectra from their own instruments using their individual fit software. All the fit errors of HONO dSCDs from the instruments with cooled large-size detectors are mostly in the range of 0.1 to 0.3 × 1015 molecules cm−2 for an integration time of 1 min. The fit error for the mini MAX-DOAS is around 0.7 × 1015 molecules cm−2. Although the HONO delta SCDs are normally smaller than 6 × 1015 molecules cm−2, consistent time series of HONO delta SCDs are retrieved from the measurements of different instruments. Both fits with a sequential Fraunhofer reference spectrum (FRS) and a daily noon FRS lead to similar consistency. Apart from the mini-MAX-DOAS, the systematic absolute differences of HONO delta SCDs between the instruments are smaller than 0.63 × 1015 molecules cm−2. The correlation coefficients are higher than 0.7 and the slopes of linear regressions deviate from unity by less than 16 % for the elevation angle of 1°. The correlations decrease with an increase in elevation angle. All the participants also analysed synthetic spectra using the same baseline DOAS settings to evaluate the systematic errors of HONO results from their respective fit programs. In general the errors are smaller than 0.3 × 1015 molecules cm−2, which is about half of the systematic difference between the real measurements. The differences of HONO delta SCDs retrieved in the selected three spectral ranges 335–361, 335–373 and 335–390 nm are considerable (up to 0.57 × 1015 molecules cm−2) for both real measurements and synthetic spectra. We performed sensitivity studies to quantify the dominant systematic error sources and to find a recommended DOAS setting in the three spectral ranges. The results show that water vapour absorption, temperature and wavelength dependence of O4 absorption, temperature dependence of Ring spectrum, and polynomial and intensity offset correction all together dominate the systematic errors. We recommend a fit range of 335–373 nm for HONO retrievals. In such fit range the overall systematic uncertainty is about 0.87 × 1015 molecules cm−2, much smaller than those in the other two ranges. The typical random uncertainty is estimated to be about 0.16 × 1015 molecules cm−2, which is only 25 % of the total systematic uncertainty for most of the instruments in the MAD-CAT campaign. In summary for most of the MAX-DOAS instruments for elevation angle below 5°, half daytime measurements (usually in the morning) of HONO delta SCD can be over the detection limit of 0.2 × 1015 molecules cm−2 with an uncertainty of ∼ 0.9 × 1015 molecules cm−2.
The tropospheric vertical column density of NO2 (Trop NO2 VCD) can be obtained using satellite remote sensing, but it has been discovered that the Trop NO2 VCD is affected by uncertainties such as the cloud fraction, terrain reflectivity, and aerosol optical depth. A certain error occurs in terms of data inversion accuracy, necessitating additional ground observation verification. This study uses surface NO2 mass concentrations from the China National Environmental Monitoring Center (CNEMC) sites in Jiangsu Province, China in 2019 and the Trop NO2 VCD measured by MAX-DOAS, respectively, to verify the Trop NO2 VCD product (daily and monthly average data), that comes from the TROPOspheric Monitoring Instrument (TROPOMI) and Ozone Monitoring Instrument (OMI). The results show that the spatial distributions of NO2 in TROPOMI and OMI exhibit a similar tendency and seasonality, showing the characteristics of being high in spring and winter and low in summer and autumn. On the whole, the concentration of NO2 in the south of Jiangsu Province is higher than that in the north. The Pearson correlation coefficient (r) between the monthly average TROPOMI VCD NO2 and the CNEMC NO2 mass concentration is 0.9, which is greater than the r (0.78) between OMI and CNEMC; the r (0.69) between TROPOMI and the MAX-DOAS VCD NO2 is greater than the r (0.59) between OMI and the MAX-DOAS. As such, the TROPOMI is better than the previous generation of OMI at representing the spatio-temporal distribution of NO2 in the regional scope. On the other hand, the uncertainties of the satellite products provided in this study can constrain regional air quality forecasting models and top-down emission inventory estimation.
NOX (NOX = NO + NO2) emissions measurements in Beijing are of great significance because they can aid in understanding how NOX pollution develops in mega-cities throughout China. However, NOX emissions in mega-cities are difficult to measure due to changes in wind patterns and moving sources on roads during measurement. To obtain good spatial coverage on different ring roads in Beijing over a short amount of time, two mobile differential optical absorption spectroscopy (DOAS) instruments were used to measure NOX emission flux from April 18th to 26th, 2018. In addition, a wind profile radar provided simultaneous wind field measurements for altitudes between 50 m and 1 km for each ring road measurement. We first determined NOX emission flux of different ring roads using wind field averages from measured wind data. The results showed that the NOX emission flux of Beijing’s fifth ring road, which represented the urban part, varied from (19.29 ± 5.26) × 1024 molec./s to (36.46 ± 12.86) × 1024 molec./s. On April 20th, NOX emission flux for the third ring was slightly higher than the fourth ring because the two ring roads were measured at different time periods. We then analyzed the NOX emission flux error budget and error sensitivity. The main error source was the wind field uncertainty. For some measurements, the main emission flux error source was either wind speed uncertainty or wind direction uncertainty, but not both. As Beijing’s NOX emissions came from road vehicle exhaust, we found that emission flux error had a more diverse sensitivity to wind direction uncertainty, which improved our knowledge on this topic. The NOX emission flux error sensitivity study indicated that more accurate measurements of the wind field are crucial for effective NOX emission flux measurements in Chinese mega-cities. Obtaining actual time and high resolved wind measurements is an advantage for mega-cities’ NOX emission flux measurements. The emission flux errors caused by wind direction and wind speed uncertainties were clearly distinguished. Other sensitivity studies indicated that NOX/NO2 ratio uncertainty dominated flux errors when the NOX/NO2 ratio uncertainty was >0.4. Using two mobile-DOAS and wind profile radars to measure NOx emission flux improved the quality of the emission flux measuring results. This approach could be applied to many other mega-cities in China and in others countries.