The search for novel image contrasts has been a major driving force in the magnetic resonance (MR) research community, in order to gain further information on the body’s physiological and pathological conditions. Chemical exchange saturation transfer (CEST) is a novel MR technique that enables imaging certain compounds at concentrations that are too low to impact the contrast of standard MR imaging and too low to directly be detected in MRS at typical water imaging resolution. For this to be possible, the target compound must be capable of exchanging protons with the surrounding water molecules. This property can be exploited to cause a continuous buildup of magnetic saturation of water, leading to greatly enhanced sensitivity. The goal of the present review is to introduce the basic principles of CEST imaging to the general molecular imaging community. Special focus has been given to the comparison of state-of-the-art CEST methods reported in the literature with their positron emission tomography (PET) counterparts.
16 October 2014 in Journal of Therapeutic Ultrasound
Magnetic resonance-guided focused ultrasound surgery (MRgFUS) allows for precise thermal ablation of target tissues. While this emerging modality is increasingly used for the treatment of various types of extracranial soft tissue tumors, it has only recently been acknowledged as a modality for noninvasive neurosurgery. MRgFUS has been particularly successful for functional neurosurgery, whereas its clinical application for tumor neurosurgery has been delayed for various technical and procedural reasons. Here, we report the case of a 63-year-old patient presenting with a centrally located recurrent glioblastoma who was included in our ongoing clinical phase I study aimed at evaluating the feasibility and safety of transcranial MRgFUS for brain tumor ablation. Applying 25 high-power sonications under MR imaging guidance, partial tumor ablation could be achieved without provoking neurological deficits or other adverse effects in the patient. This proves, for the first time, the feasibility of using transcranial MR-guided focused ultrasound to safely ablate substantial volumes of brain tumor tissue.
Purpose: To evaluate the reproducibility of γ‐amino‐butyric acid (GABA) and glutamate concentrations derived using three different spectral fitting methods, and to investigate gender‐related differences in neurotransmitter levels.Materials and Methods: Single voxel MEGA‐edited PRESS MR spectra were acquired from a 30‐mL voxel in the dorso‐lateral prefrontal cortex in 14 adult volunteers (7 female) at 3 Tesla (3T). For each participant, four consecutive resting spectra were acquired within the same scanning session. Metabolite concentrations were derived using LCModel, jMRUI, and locally written peak fitting software. The within‐session reproducibility for each analysis method was calculated as the average coefficient of variation (CV) of the GABA and Glx (glutamate+glutamine) concentrations. Gender differences in GABA and Glx were evaluated using a two‐tailed unpaired t‐test.Results: LCModel provided the best reproducibility for both GABA (CV 7%) and Glx (CV 6%). GABA, Glx, and glutamate concentrations were significantly higher in the male participants, (P = 0.02, P = 0.001, and P < 0.001, respectively).Conclusion: GABA and glutamate can be quantified in vivo with high reproducibility (CV 6–7%) using frequency‐domain spectral fitting methods like LCModel. However, the GABA and glutamate concentrations vary significantly between men and women, emphasizing the importance of gender‐matching for studies investigating differences in neurotransmitter concentrations between mixed‐cohort groups. J. Magn. Reson. Imaging 2011;33:1262–1267.