Chien-Yuan Lin

Dr. Chien-Yuan Lin

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2016 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
BWB. Wu
B. Wu
GWG. Warnock
G. Warnock
MZM. Zaiss
M. Zaiss
CLChien-Yuan Lin
Chien-Yuan Lin
MCM. Chen
M. Chen
GDG. Delso
G. Delso
The search for novel image contrasts has been a major driving force in the magnetic resonance (MR) research community, in order to gain further information on the body’s physiological and pathological conditions. Chemical exchange saturation transfer (CEST) is a novel MR technique that enables imaging certain compounds at concentrations that are too low to impact the contrast of standard MR imaging and too low to directly be detected in MRS at typical water imaging resolution. For this to be possible, the target compound must be capable of exchanging protons with the surrounding water molecules. This property can be exploited to cause a continuous buildup of magnetic saturation of water, leading to greatly enhanced sensitivity. The goal of the present review is to introduce the basic principles of CEST imaging to the general molecular imaging community. Special focus has been given to the comparison of state-of-the-art CEST methods reported in the literature with their positron emission tomography (PET) counterparts.

11 February 2020 in Radiology
Verified
Journal Article
Closed access
MPMichal Považan
Michal Považan
MMMark Mikkelsen
Mark Mikkelsen
ABAdam Berrington
Adam Berrington
PBPallab Bhattacharyya
Pallab Bhattacharyya
MBMaiken K. Brix
Maiken K. Brix
PBPeter B Barker
Peter B Barker
In a multisite study of brain MR spectroscopy performed at 26 sites, interindividual differences were found as the main contributor to variability, demonstrating that appropriately analyzed MR spec... Background The hardware and software differences between MR vendors and individual sites influence the quantification of MR spectroscopy data. An analysis of a large data set may help to better und...

Verified
Journal Article
Open access
PDF file
CLChia-Wei Li
Chia-Wei Li
AHAi-Ling Hsu
Ai-Ling Hsu
CHChi-Wen C. Huang
Chi-Wen C. Huang
SYShih-Hung Yang
Shih-Hung Yang
CLChien-Yuan Lin
Chien-Yuan Lin
WCWING P. CHAN
WING P. CHAN
The reliability of relaxation time measures in synthetic magnetic resonance images (MRIs) of homemade phantoms were validated, and the diagnostic suitability of synthetic imaging was compared to that of conventional MRIs for detecting ischemic lesions. Phantoms filled with aqueous cupric-sulfate (CuSO4) were designed to mimic spin-lattice (T1) and spin-spin (T2) relaxation properties and were used to compare their accuracies and stabilities between synthetic and conventional scans of various brain tissues. To validate the accuracy of synthetic imaging in ischemic stroke diagnoses, the synthetic and clinical scans of 18 patients with ischemic stroke were compared, and the quantitative contrast-to-noise ratios (CNRs) were measured, using the Friedman test to determine significance in differences. Results using the phantoms showed no significant differences in the interday and intersession synthetic quantitative T1 and T2 values. However, between synthetic and referenced T1 and T2 values, differences were larger for longer relaxation times, showing that image intensities in synthetic scans are relatively inaccurate in the cerebrospinal fluid (CSF). Similarly, CNRs in CSF regions of stroke patients were significantly different on synthetic T2-weighted and T2-fluid-attenuated inversion recovery images. In contrast, differences in stroke lesions were insignificant between the two. Therefore, interday and intersession synthetic T1 and T2 values are highly reliable, and discrepancies in synthetic T1 and T2 relaxation times and image contrasts in CSF regions do not affect stroke lesion diagnoses. Additionally, quantitative relaxation times from synthetic images allow better estimations of ischemic stroke onset time, consequently increasing confidence in synthetic MRIs as diagnostic tools for ischemic stroke.

16 August 2019 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
MWMing-Chen Wu
Ming-Chen Wu
MHMing-Yi Hsu
Ming-Yi Hsu
RSRen-Fu Shie
Ren-Fu Shie
MCMing-Huei Cheng
Ming-Huei Cheng
FCFang-I Chu
Fang-I Chu
SCSung-Yu Chu
Sung-Yu Chu
The aim of this study was to compare non-contrast-enhanced 3D phase contrast magnetic resonance angiography (3D PC-MRA) and conventional intravenous administration of contrast media, i.e., contrast-enhanced MRA (CE-MRA), to evaluate the courses of facial arteries for the preparation of vascularized submental lymph node flap (VSLN flap) transfer. The head and neck regions of 20 patients with limb lymphedema were imaged using a 3 T MRI scanner. To improve the evaluation of facial artery courses, MRA was fused with anatomical structures generated by high-resolution T1-weighted imaging. The diagnostic and image qualities of facial arteries for VSLN flap planning were independently rated by two radiologists. Interobserver agreement was evaluated using Cohen’s kappa. Differences between 3D PC-MRA and CE-MRA in terms of the diagnostic quality of facial arteries were evaluated using McNemar’s test. Cohen’s kappa indicated fair to good interobserver agreement for the diagnostic and image qualities of the bilateral facial arteries. No significant difference in terms of the diagnostic quality of the left and right facial arteries between 3D PC-MRA and CE-MRA, respectively, was identified. Non-contrast 3D PC-MRA is a reliable method for the evaluation of facial artery courses prior to VSLN flap transfer and could serve as an alternative to CE-MRA for patients with renal insufficiency or severe adverse reactions to contrast media.

23 June 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
BHBo-Syuan Huang
Bo-Syuan Huang
CHChing-Yi Hsieh
Ching-Yi Hsieh
WCWen-Yen Chai
Wen-Yen Chai
YLYenpo Lin
Yenpo Lin
YHYen-Ling Huang
Yen-Ling Huang
Gigin LinGigin Lin
Gigin Lin
The aim of this study was to explore the potential of magnetic resonance fingerprinting (MRF), an emerging quantitative MRI technique, in measuring relaxation values of female pelvic tissues compared to the conventional magnetic resonance image compilation (MAGiC) sequence. The study included 32 female patients who underwent routine pelvic MRI exams using anterior and posterior array coils on a 3T clinical scanner. Our findings demonstrated significant correlations between MRF and MAGiC measured T1 and T2 values (p < 0.0001) for various pelvic tissues, including ilium, femoral head, gluteus, obturator, iliopsoas, erector spinae, uterus, cervix, and cutaneous fat. The tissue contrasts generated from conventional MRI and synthetic MRF also showed agreement in bone, muscle, and uterus for both T1-weighted and T2-weighted images. This study highlights the strengths of MRF in providing simultaneous T1 and T2 mapping. MRF offers distinct tissue contrast and has the potential for accurate diagnosis of female pelvic diseases, including tumors, fibroids, endometriosis, and pelvic inflammatory disease. Additionally, MRF shows promise in monitoring disease progression or treatment response. Overall, the study demonstrates the potential of MRF in the field of female pelvic organ imaging and suggests that it could be a valuable addition to the clinical practice of pelvic MRI exams. Further research is needed to establish the clinical utility of MRF and to develop standardized protocols for its implementation in clinical practice.

31 October 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
ZYZezhong Ye
Zezhong Ye
SGSam E. Gary
Sam E. Gary
PSPeng Sun
Peng Sun
SMSourajit Mitra Mustafi
Sourajit Mitra Mustafi
GGGeorge Russell Glenn
George Russell Glenn
SSSheng-Kwei Song
Sheng-Kwei Song
Purpose: Diffusion tensor imaging (DTI) has been employed for over two decades to noninvasively quantify central nervous system (CNS) diseases/injuries. However, DTI is an inadequate simplification of diffusion modeling in the presence of co-existing inflammation, edema, and crossing nerve fibers. Methods: We employed a tissue phantom using fixed mouse trigeminal nerves coated with various amounts of agarose gel to mimic crossing fibers in the presence of vasogenic edema. Diffusivity measures derived by DTI and diffusion basis spectrum imaging (DBSI) were compared at increasing levels of simulated edema and degrees of fiber crossing. Further, we assessed the ability of DBSI, diffusion kurtosis imaging (DKI), generalized q-sampling imaging (GQI), q-ball imaging (QBI), and neurite orientation dispersion and density imaging (NODDI) to resolve fiber crossing, in reference to the gold standard angles measured from structural images. Results: DTI-computed diffusivities and fractional anisotropy (FA) were significantly confounded by gelmimicked edema and crossing fibers. Conversely, DBSI calculated accurate diffusivities of individual fibers regardless of the extent of simulated edema and degrees of fiber crossing angles. Additionaly, DBSI accurately and consistently estimated crossing angles in various conditions of gel-mimicked edema when comparing with gold standard (r 2 =0.92, p=1.9×10 −9 , bias=3.9°). Small crossing angles and edema sinficantly impact dODF, making DKI, GQI and QBI less accurate in detecting and estimating fibers corrsing angles. Lastly, we demonstrate DBSI’s superiority over DTI for recovering and delineating white matter tracts in peritumoral edema for preoperative planning of surgical resection. Conclusions: DBSI is able to separate two crossing fibers and accurately recover their diffusivities in a complex environment characterized by increasing crossing angles and amounts of gel-mimicked edema. DBSI also indicated better angular resolution capability compared with DKI, QBI and GQI.