Michal Považan

Michal Považan

Auto-generated profile, based on publicly available information

Michal Považan

Russell H. Morgan Department of Radiology and Radiological Science The Johns Hopkins University School of Medicine Baltimore Maryland USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in NeuroImage
Verified
Journal Article
Open access
GHGilbert Hangel
Gilbert Hangel
BSBernhard Strasser
Bernhard Strasser
MPMichal Považan
Michal Považan
EHEva Heckova
Eva Heckova
LHLukas Hingerl
Lukas Hingerl
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
MRSI in the brain at ≥7 T is a technique of great promise, but has been limited mainly by low B0/B1+-homogeneity, specific absorption rate restrictions, long measurement times, and low spatial resolution. To overcome these limitations, we propose an ultra-high resolution (UHR) MRSI sequence that provides a 128×128 matrix with a nominal voxel volume of 1.7×1.7×8mm3 in a comparatively short measurement time. A clinically feasible scan time of 10-20min is reached via a short TR of 200 ms due to an optimised free induction decay-based acquisition with shortened water suppression as well as parallel imaging (PI) using Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration (CAIPIRINHA). This approach is not limited to a rectangular region of interest in the centre of the brain, but also covers cortical brain regions. Transversal pulse-cascaded Hadamard encoding was able to further extend the coverage to 3D-UHR-MRSI of four slices (100×100×4 matrix size), with a measurement time of 17min. Lipid contamination was removed during post-processing using L2-regularisation. Simulations, phantom and volunteer measurements were performed. The obtained single-slice and 3D-metabolite maps show the brain in unprecedented detail (e.g., hemispheres, ventricles, gyri, and the contrast between grey and white matter). This facilitates the use of UHR-MRSI for clinical applications, such as measurements of the small structures and metabolic pathologic deviations found in small Multiple Sclerosis lesions.

16 December 2020 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
ITIvan Tkáč
Ivan Tkáč
DDDinesh Deelchand
Dinesh Deelchand
WDWolfgang Dreher
Wolfgang Dreher
HHHoby Hetherington
Hoby Hetherington
RKRoland Kreis
Roland Kreis
RGRobin A. de Graaf
Robin A. de Graaf

2 February 2021 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
HZHelge J. Zöllner
Helge J. Zöllner
MPMichal Považan
Michal Považan
SHSteve C.N. Hui
Steve C.N. Hui
STSofie Tapper
Sofie Tapper
RERichard A.E. Edden
Richard A.E. Edden
GOGeorg Oeltzschner
Georg Oeltzschner

1 November 2015 in NeuroImage
Verified
Journal Article
Open access
MPMichal Považan
Michal Považan
GHGilbert Hangel
Gilbert Hangel
BSBernhard Strasser
Bernhard Strasser
SGStephan Gruber
Stephan Gruber
MCMarek Chmelik
Marek Chmelik
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
Long echo time (TE) MR spectroscopy (MRS) sequences are sensitive only to metabolites of low molecular weight. At shorter TE, significantly more metabolite signals are detectable, including broad signals of high-molecular-weight macromolecules (MMs). Although the presence of MM resonances can bias metabolite quantification at short TE, proper quantification of MMs is important since MMs themselves may serve as potentially valuable biomarkers for many pathologies. We have therefore developed an FID-based 2D-MR Spectroscopic Imaging (2D-MRSI) sequence to map MMs in healthy brain tissue at 7 T within a scan time of ~17 min and a repetition time of 879 ms. This 2D-MRSI technique provides MM maps over a whole slice (i.e., including cortical gray matter) at an ultra-short acquisition delay of 1.3 ms, using double inversion for efficient nulling of low-molecular-weight metabolites. The optimal sequence parameters were estimated using Bloch simulations, phantom testing, and in vivo validation. The acquired in vivo MM spectra (n=6) included nine distinct MM peaks in the range of ~0.9-3.7 ppm. The measured average MM spectrum was incorporated into the LCModel basis set and utilized for further quantification of MRSI data sets without metabolite nulling, which were acquired in five additional volunteers. The quantification results for two basis sets, one including the MMs and one without MM spectrum, were compared. Due to the high spectral resolution and full signal detection provided by the FID-MRSI sequence, we could successfully map five important brain metabolites. Most quantified metabolite signal amplitudes were significantly lower since the inclusion of MMs into the basis set corrected the overestimation of metabolite signals. The precision of fit (i.e., Cramér Rao lower bounds) remained unchanged. Our MM maps show that the overall MM contribution was higher in gray matter than in white matter. In conclusion, the acquired MM spectrum improved the accuracy of metabolite quantification and allowed the acquisition of high spatial resolution maps of five major brain metabolites and also MMs.

6 November 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
LHLukas Hingerl
Lukas Hingerl
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
PMPhilipp Moser
Philipp Moser
MPMichal Považan
Michal Považan
GHGilbert Hangel
Gilbert Hangel
BSBernhard Strasser
Bernhard Strasser
Purpose: Full‐slice magnetic resonance spectroscopic imaging at T is especially vulnerable to lipid contaminations arising from regions close to the skull. This contamination can be mitigated by improving the point spread function via higher spatial resolution sampling and k‐space filtering, but this prolongs scan times and reduces the signal‐to‐noise ratio (SNR) efficiency. Currently applied parallel imaging methods accelerate magnetic resonance spectroscopic imaging scans at 7T, but increase lipid artifacts and lower SNR‐efficiency further. In this study, we propose an SNR‐efficient spatial‐spectral sampling scheme using concentric circle echo planar trajectories (CONCEPT), which was adapted to intrinsically acquire a Hamming‐weighted k‐space, thus termed density‐weighted‐CONCEPT. This minimizes voxel bleeding, while preserving an optimal SNR.Theory and Methods: Trajectories were theoretically derived and verified in phantoms as well as in the human brain via measurements of five volunteers (single‐slice, field‐of‐view 220 × 220 mm2, matrix 64 × 64, scan time 6 min) with free induction decay magnetic resonance spectroscopic imaging. Density‐weighted‐CONCEPT was compared to (a) the originally proposed CONCEPT with equidistant circles (here termed e‐CONCEPT), (b) elliptical phase‐encoding, and (c) 5‐fold Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration accelerated elliptical phase‐encoding.Results: By intrinsically sampling a Hamming‐weighted k‐space, density‐weighted‐CONCEPT removed Gibbs‐ringing artifacts and had in vivo +9.5%, +24.4%, and +39.7% higher SNR than e‐CONCEPT, elliptical phase‐encoding, and the Controlled Aliasing In Parallel Imaging Results IN Higher Acceleration accelerated elliptical phase‐encoding (all P < 0.05), respectively, which lead to improved metabolic maps.Conclusion: Density‐weighted‐CONCEPT provides clinically attractive full‐slice high‐resolution magnetic resonance spectroscopic imaging with optimal SNR at 7T. Magn Reson Med 79:2874–2885, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

22 August 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
BSBernhard Strasser
Bernhard Strasser
MPM. Považan
M. Považan
GHGilbert Hangel
Gilbert Hangel
LHL. Hingerl
L. Hingerl
MCM. Chmelik
M. Chmelik
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
Purpose To compare a new parallel imaging (PI) method for multislice proton magnetic resonance spectroscopic imaging (1H‐MRSI), termed (2 + 1)D‐CAIPIRINHA, with two standard PI methods: 2D‐GRAPPA and 2D‐CAIPIRINHA at 7 Tesla (T). Methods (2 + 1)D‐CAIPIRINHA is a combination of 2D‐CAIPIRINHA and slice‐CAIPIRINHA. Eight healthy volunteers were measured on a 7T MR scanner using a 32‐channel head coil. The best undersampling patterns were estimated for all three PI methods. The artifact powers, g‐factors, Cramér–Rao lower bounds (CRLB), and root mean square errors (RMSE) were compared quantitatively among the three PI methods. Metabolic maps and spectra were compared qualitatively. Results (2 + 1)D‐CAIPIRINHA allows acceleration in three spatial dimensions in contrast to 2D‐GRAPPA and 2D‐CAIPIRINHA. Thus, this sequence significantly decreased the RMSE of the metabolic maps by 12.1 and 6.9%, on average, for 4 < R < 11, compared with 2D‐GRAPPA and 2D‐CAIPIRINHA, respectively. The artifact power was 22.6 and 8.4% lower, and the CRLB were 3.4 and 0.6% lower, respectively. Conclusion (2 + 1)‐CAIPIRINHA can be implemented for multislice MRSI in the brain, enabling higher accelerations than possible with two‐dimensional (2D) parallel imaging methods. An eight‐fold acceleration was still feasible in vivo with negligible PI artifacts with lipid decontamination, thus decreasing the measurement time from 120 to 15 min for a 64 × 64 × 4 matrix. Magn Reson Med 78:429–440, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.