Tomasz Wach

Dr. Tomasz Wach

Medical university of Lodz, Department of Maxillofacial Surgery
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
Marcin KozakiewiczMarcin Kozakiewicz
Marcin Kozakiewicz
TWTomasz Wach
Tomasz Wach
PSPiotr Szymor
Piotr Szymor
RZRafał Zieliński
Rafał Zieliński

30 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
Marcin KozakiewiczMarcin Kozakiewicz
Marcin Kozakiewicz
TWTomasz Wach
Tomasz Wach
This article presents a comparison of bone replacement materials in terms of their ability to produce living bone image at the place of their implantation. Five bone replacement materials are compared (Osteovit—porous collagen, Cerasorb Foam—collagen scaffolding of synthetic β tricalcium phosphate, Osbone—synthetic hydroxyapatite, Endobone—deproteinized bovine-derived cancellous bone hydroxyapatite, and Cerasorb—synthetic β tricalcium phosphate). Intraoral radiographs are taken immediately after implantation and 12 months later. The texture analysis was performed to assess (texture index, TI) the level of structure chaos (entropy) in relation to the presence of longitudinal elements visible in radiographs (run length emphasis moment). The reference ratio of the chaotic trabecular pattern (Entropy) to the number of longitudinal structures, i.e., trabeculae (LngREmph), is 176:100 (i.e., 1.76 ± 0.28). Radiological homogeneity immediately after the implantation procedure is a result of the similar shape of its particles (Osbone, Endobone and Cerasorb) or radiolucency (Osteovit, Cerasorb Foam). The particles visible in radiographs were similar in the LngREmph parameters applied to the reference bone, but not in the co-occurrence matrix features. The TI for Osteovit during a 12-month follow-up period changed from 1.55 ± 0.26 to 1.48 ± 0.26 (p > 0.05), for Cerasorb Foam from 1.82 ± 0.27 to 1.63 ± 0.24 (p < 0.05), for Osbone from 1.97 ± 0.31 to 1.74 ± 0.30 (p < 0.01), and for Endobone from 1.86 ± 0.25 to 1.84 ± 0.25 (p > 0.05), The observed structure in the radiological image of bone substitute materials containing calcium phosphates obtains the characteristics of a living bone image after twelve months.

1 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
TWTomasz Wach
Tomasz Wach
Marcin KozakiewiczMarcin Kozakiewicz
Marcin Kozakiewicz
The development of oral surgery and implantology has led to the need for better and more predictable materials. Various substitute materials are now used for bone regeneration. The replacement of scaffolding material by new bone tissue is the most important condition. This study aimed to evaluate the effects of the resorbability of bone substitute materials during regeneration to the jawbone. The study included 88 patients during the 12-month follow-up. All the patients had undergone oral surgical procedures using two different substitute materials—Cerasorb (high-rate resorbable (β-tricalcium phosphate)) and Endobone (low-rate resorbable (hydroxyapatite)). Texture analysis was performed in intraoral radiographs, in which regions of interest were established for the bone substitute materials and reference bone. Five texture features were calculated, namely the sum average (SumAverg), entropy (Entropy), and three Harr discrete wavelet transform coefficients. This study revealed that all 5 features described the healing process well. Entropy was decreased in both cases with time; however, in Cerasorb cases, the texture feature values were very close to those of the reference bone after 12 months of healing (p < 0.05). The wavelet transform coefficient at scale 6 also showed that longitudinal objects appeared in implantation sites, similar to trabecular bone (p < 0.05) after 12 months of healing. The slow-resorbing material restored the structure of the alveolar crest better in terms of producing large objects similar to the components of a barrel bone image (wavelet coefficients), but required a longer time for reconstruction. The fast-resorbing material showed a texture image with a similar scattering of structures to that of the reference bone (entropy) after 12 months.


19 August 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
BWBarbara Wojciechowska
Barbara Wojciechowska
ASArkadiusz Szarmach
Arkadiusz Szarmach
Adam MichcikAdam Michcik
Adam Michcik
TWTomasz Wach
Tomasz Wach
BDBarbara Drogoszewska
Barbara Drogoszewska
Background: Temporomandibular disorders are common conditions characterized by discomfort within the temporomandibular joints, acoustic changes, and restricted mandibular movement. Accurate diagnosis and subsequent treatment rely heavily on clinical examination, but it is often necessary to add radiological examinations to the diagnostics. Magnetic Resonance Imaging (MRI) is the gold standard for visualizing the disc, while cone-beam computed tomography (CBCT) is primarily used for evaluating condylar morphology. Ultrasound (US) serves as a real-time imaging modality for soft tissues. The objective of the present study was to explore the association between clinical manifestations observed in patients with temporomandibular joint disorders and corresponding radiographic findings. Methods: A total of 63 adult patients (51 female and 12 male) with temporomandibular joint disorders were included in this cross-sectional study. Each patient underwent a clinical examination, followed by appropriate radiological examinations (MRI, CBCT, or US). The level of statistical significance was set at an alpha of 0.05. The Shapiro–Wilk test assessed the normality of numerical variables. The Wilcoxon rank sum test compared two independent groups with non-normally distributed data. Relationships between categorical variables were evaluated using the Pearson chi-square test or Fisher’s exact test. The Kendall tau (τ) method analyzed the correlation between two binary variables. Results: The analysis included 63 patients with TMD, predominantly females (80.95%). Ages ranged from 18 to 74 years with a median of 39 years. In the CBCT study, we observed rarefied changes in the left bone structures in patients with bruxism (p = 0.010). MRI and ultrasound imaging revealed changes in patients with limited jaw opening: erosions in the right mandibular head on ultrasound (p = 0.008) and abnormal right bone structures on MRI (p = 0.009). In CBCT, asymmetry in the left joint space was correlated with a high incidence of right side muscle tension (p = 0.004). Additionally, both CBCT and ultrasound showed a correlation between muscle tension and erosion (p = 0.040 in ultrasound, p = 0.020 in CBCT). Acoustic changes, when compared with radiological imaging, were evident in all three studies, like temporomandibular joint pain or palpation. Conclusions: Our study compared three radiographic imaging methods with clinical examinations to assess their correlation with clinical symptoms. Each imaging technique provided unique insights depending on the specific symptoms presented. The observed correlations varied, highlighting the unique contributions of each modality to the diagnostic process. This underscores the importance of employing multiple diagnostic approaches for a thorough assessment of the temporomandibular joint. However, a limitation of our study is the small sample size and the uneven distribution of participants among the groups. Additionally, not all patients underwent every imaging modality.

Verified
Journal Article
Open access
PDF file
Marcin KozakiewiczMarcin Kozakiewicz
Marcin Kozakiewicz
MSMałgorzata Skorupska
Małgorzata Skorupska
TWTomasz Wach
Tomasz Wach
The phenomenon of peri-implant bone corticalization after functional loading does not yet have a definite clinical significance and impact on prognosis. An attempt was made to assess the clinical significance of this phenomenon. This prospective study included 554 patients. Standardized intraoral radiographs documenting the jawbone environment of 1556 implants were collected. The follow-up period was 10 years of functional loading. Marginal alveolar bone loss (MBL) and radiographic bone structure (bone index, BI) were evaluated in relation to intraosseous implant design features and prosthetic work performed. After five years, bone structure abnormalities expressed by a reduction of BI to 0.47 ± 0.21 and MBL = 0.88 ± 1.27 mm were observed. Both values had an inverse relationship with each other (p < 0.0001). Reference cancellous bone showed BI = 0.85 ± 0.18. The same relationship was observed after ten years of functional loading: BI = 0.48 ± 0.21, MBL = 1.49 ± 1.94 mm, and again an inverse relationship (p < 0.0001). Increasing corticalization (lower BI) is strongly associated with increasing marginal bone loss and increasing corticalization precedes future marginal bone loss. Marginal bone loss will increase as corticalization progresses.