Infection risk management in a dental unit waterline (DUWL) involves healthcare personnel and patients and is related to routine exposure to water and aerosols that may contain bacterial species. To improve water safety plans, maintenance, and sanitation procedures, analyses of heterotrophic plate counts (HPCs) at 36 °C, and two other microorganisms frequently associated with biofilms, Pseudomonas aeruginosa and Legionella spp., were performed in order to evaluate differences in microbiological contamination between two types of DUWLs: Type A, provided by a water tank, and Type B, directly connected to municipal water. The data showed that the water supply and water safety plan differentially influenced microbiological contamination: Type A DUWLs were more contaminated than Type B DUWLs for all microbiological parameters tested, with significant changes in the percentage of positive samples and contamination levels that were beyond the limits of standard guidelines. The results obtained show how the storage tank, the absence of anti-retraction valves, and the disinfection procedures performed are the main critical points of Type A DUWLs, which confirms that dental unit management (maintenance/sanitization) is often missed or not correctly applied by stakeholders, with an underestimation of the real risk of infection for patients and operators.
Dental unit waterlines (DUWLs) represent a complex environment able to promote microbial contamination, due to functional, mechanical and practical risk factors. According to a water safety plan approach, the main goal is to preserve the health of dentists, dental staff and patients. The aim of this study is to develop a DUWLs water safety plan that is able to support correct and effective maintenance and disinfection procedures. Three different water systems serve 60 dental chairs: (i) water that comes directly from municipal water (Type A), (ii) water supplied by municipal water and water bottles (Type B) and (iii) water supplied only via water bottles (Type C). For each type, Legionella and Pseudomonas aeruginosa contamination was studied, by applying a new sampling scheme, based on separate sampling from water bottles, cup filler and handpieces. Type B DUWL is the only type of DUWL contaminated by L. pneumophila (ST 59) and L. anisa (mean contamination: 608.33 ± 253.33 cfu/L) detected in cup filler and handpieces, as well as the high presence of P. aeruginosa (44.42 ± 13.25 cfu/100 mL). Two subsequent shock treatments and resampling procedures were performed by increasing disinfectant dosage and contact time and removing some DUWL components linked to biofilm growth in DUWLs. A significant reduction of contamination was obtained for both microorganisms (Legionella spp.: -100%, p < 0.001 and P. aeruginosa: -99.86%, p = 0.006). The sampling strategy proposed allows us to identify the source of contamination and better focus on the maintenance and disinfection procedures. DUWLs represent an environment that requires a multidisciplinary approach, combining the knowledge of all DUWL components to correct procedures that are able to preserve the health of personnel and patients, as well as guaranteeing DUWLs' safe functionality.
Detection and enumeration of Legionella in water samples is of great importance for risk assessment analysis. The plate culture method is the gold standard, but has received several well-known criticisms, which have induced researchers to develop alternative methods. The purpose of this study was to compare Legionella counts obtained by the analysis of potable water samples through the plate culture method and through the IDEXX liquid culture Legiolert method. Legionella plate culture, according to ISO 11731:1998, was performed using 1 L of water. Legiolert was performed using both the 10 mL and 100 mL Legiolert protocols. Overall, 123 potable water samples were analyzed. Thirty-seven (30%) of them, positive for L. pneumophila, serogroups 1 or 2–14 by plate culture, were used for comparison with the Legiolert results. The Legiolert 10 mL test detected 34 positive samples (27.6%) and the Legiolert 100 mL test detected 37 positive samples, 27.6% and 30% respectively, out of the total samples analyzed. No significant difference was found between either the Legiolert 10 mL and Legiolert 100 mL vs. the plate culture (p = 0.9 and p = 0.3, respectively) or between the Legiolert 10 mL and Legiolert 100 mL tests (p = 0.83). This study confirms the reliability of the IDEXX Legiolert test for Legionella pneumophila detection and enumeration, as already shown in similar studies. Like the plate culture method, the Legiolert assay is also suitable for obtaining isolates for typing purposes, relevant for epidemiological investigations.
Legionella species distribution in the Emilia-Romagna region, involving hospital (H) and community (C) environments, was conducted. Legionella culture, agglutination test, and mip-gene sequencing were applied on 240 isolates. The analysis showed a higher prevalence of non-Legionellapneumophila (n-Lp) species (84.1%) compared with L. pneumophila (Lp) (15.9%), with a higher frequency of n-Lp with respect to Lp species in both environments (77.6% and 96.4%, in H and C, respectively). The Shannon index showed a significant difference in Legionella distribution (p = 0.00017), with a significant abundance of Lp in the H compared with C environment (p = 0.00028). The continuous disinfection treatment in H could contribute to adaptive survival of the Lp species. Phylogenetic analysis revealed a conservative clade distribution between H and C: L. feeleii clade with three subclades in C and the Lp clade with five subclades in H and two in C, respectively. Our findings suggest the importance of Legionella surveillance both in H and C, with a focus on n-Lp species less connected to human disease. The Legionella prevalence and diversity found here indicate that geographical and temporal isolate evolution should be considered during surveillance, particularly in the light of global warming and changes in population risk factors.
In man-made water distribution systems, Legionella community interactions remain unknown, due to their ability to change from sessile to planktonic states or live in viable but non-culturable forms, in response to anthropic and environmental stress. During 7 years of hospital Legionella surveillance, in 191 hot water positive samples, the interactions among the Legionella species, temperature, and disinfection treatment were evaluated. Legionella was isolated following ISO 11731:2017, and identification was performed by mip gene sequencing and sequence-based typing (SBT) for L. anisa or L. rubrilucens and L. pneumophila, respectively. The species with the higher frequency of isolation was L. pneumophila serogroup 1 (78.53%; 4865.36 ± 25,479.11 cfu/L), followed by L. anisa (54.45%; 558.79 ± 2637.41 cfu/L) and L. rubrilucens (21.99%; 307.73 ± 1574.95 cfu/L), which were sometimes present together. Spearman’s rho correlation test was conducted among the species with respect to temperature and disinfectant (H2O2/Ag+). The results showed a generally positive interaction among these species sharing the same environment, except for competition between L. anisa and L. rubrilucens. High temperature (48.83 ± 2.59 °C) and disinfection treatment (11.58 ± 4.99 mg/L) affected the presence of these species. An exception was observed with L. anisa, which showed disinfection treatment resistance. For the purposes of environmental surveillance, it is fundamental to better understand the interactions and dynamic of the Legionella community in man-made water systems in order to choose the proper physical or chemical treatments. The simultaneous presence of different Legionella species could result in an increased resistance to high temperature and disinfectant treatment, leading to changes in contamination level and species diversity.
The use of microfiltered water dispensers (MWDs) for treatment of municipal water is increasing rapidly, however, the water quality produced by MWDs has not been widely investigated. In this work a large-scale microbiological investigation was conducted on 46 MWDs. In accordance with Italian regulations for drinking water, we investigated the heterotrophic plate counts at 36 and 22 °C for indicator bacteria and pathogenic bacteria, such as Enterococci, Pseudomonas aeruginosa, Escherichia coli and Staphylococcus aureus. Two different MWDs were compared: Type A with Ag+ coated carbon filter and two ultraviolet (UV) lamps, and Type B with a carbon filter and one UV lamp. For each type, the contamination of the input and output points was analyzed. Our findings showed that MWDs are a source of bacteria growth, with output being more contaminated than the input point. Type B was widely contaminated for all parameters tested in both sampling points, suggesting that water treatment by Type A is more effective in controlling bacterial contamination. MWDs are critical devices for water treatment in term of technologies, intended use, and sanitization procedures. The adoption of an appropriate drinking water safety plan associated with clear maintenance procedures and periodic environmental monitoring can ensure the safe and healthy operation of these devices.