Wei Wang

Dr. Wei Wang

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2013 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
WWWei Wang
Wei Wang
JLJianbin Li
Jianbin Li
HHHong Guang Hu
Hong Guang Hu
FLFeng Xiang Li
Feng Xiang Li
MXMin Xu
Min Xu
JLJie Lu
Jie Lu
Purpose: The purpose of this study was to explore the correlation between the respiration-induced target motion and volume variation with the dosimetric variance on breast and organ at risk (OAR) during free breathing. Methods and materials: After breast-conserving surgery, seventeen patients underwent respiration-synchronized 4DCT simulation scans during free breathing. Treatment planning was constructed using the end inspiration scan, then copied and applied to the other phases and the dose distribution was calculated separately to evaluate the dose-volume histograms (DVH) parameters for the planning target volume (PTV), ipsilateral lung and heart. Results: During free breathing, the treated breast motion vector was 2.09 ± 0.74 mm, and the volume variation was 3.05 ± 0.94%. There was no correlation between the breast volume and target/OAR dosimetric variation (|r| = 0.39 ~ 0.48). In the anteroposterior, superoinferior and vector directions, breast movement correlated well with the mean PTV dose, conformal index, and the lung volume receiving high dose (|r| = 0.651-0.975); in the superoinferior and vector directions, breast displacement only correlated with the heart volume receiving >5 Gy (V5) (r = −0.795, 0.687). The lung volume and the lung volume receiving high dose correlated reasonably well (r = 0.655 ~ 0.882), and a correlation only existed between heart volume and V5 (r = −0.701). Conclusion: Target movement correlated well with the target/OAR dosimetric variation in certain directions, indicating that whole breast IMRT assisted by breathing control or respiratory-adapted gated treatment promotes the accuracy of dose delivery during radiotherapy. During free breathing, the effect of breast volume variation can be ignored in whole breast IMRT.

13 March 2015 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
BGBing Guo
Bing Guo
JLJianbin Li
Jianbin Li
WWWei Wang
Wei Wang
MXMin Xu
Min Xu
QSQian Shao
Qian Shao
YGYanluan Guo
Yanluan Guo
To explore the interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on the four-dimensional computed tomography (4DCT) scan for external-beam partial breast irradiation (EB-PBI) during free breathing. Patients with a seroma clarity score (SCS) 3 ~ 5 and ≥5 surgical clips in the lumpectomy cavity after breast-conserving surgery who were recruited for EB-PBI underwent 4DCT simulation. Based on the ten sets of 4DCT images acquired, the tumour bed formed using the clips, the seroma, and both the clips and seroma (defined as TBC, TBS and TBC+S, respectively) were delineated by five radiation oncologists using specific guidelines. The following parameters were calculated to analyse interobserver variability: volume of the tumour bed (TBC, TBS, TBC+S), coefficient of variation (COVC, COVS, COVC+S), and matching degree (MDC, MDS, MDC+S). The interobserver variability for TBC and TBC+S and for COVC and COVC+S were statistically significant (p = 0.021, 0.008, 0.002, 0.015). No significant difference was observed for TBS and COVS (p = 0.867, 0.061). Significant differences in interobserver variability were observed for MDC vs MDS, MDC vs MDC+S, MDS vs MDC+S (p = 0.000, 0.032, 0.008), the interobserver variability of MDS was smaller than that of MDC and MDC+S (MDS > MDC+S > MDC). When the SCS was 3 ~ 5 points and the number of surgical clips was ≥5, interobserver variability was minimal for the delineation of the tumour bed based on seroma.

18 October 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TYTing Yu
Ting Yu
MXMin Xu
Min Xu
TSTao Sun
Tao Sun
QSQian Shao
Qian Shao
YZYingJie Zhang
YingJie Zhang
JLJianbin Li
Jianbin Li
To investigate the differences in target volumes and dosimetric parameters between the supine and prone positions for external-beam partial breast irradiation (EB-PBI) after breast-conserving surgery (BCS) for Chinese breast cancer patients, thirty breast cancer patients who underwent three-dimensional conformal radiation therapy (3DCRT) EB-PBI after BCS were enrolled. Supine and prone scan sets were acquired during free breathing for all patients. Target volumes and organs at risk (OARs) including the heart, ipsilateral lung and bilateral breast were contoured by the same radiation oncologist. For each patient, supine and prone EB-PBI plans were generated based on the same planning criteria. The clinical target volume (CTV) and planning target volume (PTV) in the prone position were significantly greater than those in the supine position (P = 0.003, 0.004, respectively). A 0.95 Gy reduction in the mean dose (Dmean) to the heart (P = 0.000) was apparent in the supine position compared to the prone position. The Dmean to the ipsilateral lung was significantly lower in the prone position than in the supine position (1.59 Gy vs. 1.72 Gy, P = 0.029). Therefore, for Chinese breast cancer patients, carrying out 3DCRT EB-PBI in the prone position during free breathing is feasible.

27 September 2013 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
JWJin Zhi Wang
Jin Zhi Wang
JLJianbin Li
Jianbin Li
WWWei Wang
Wei Wang
HQHuan Peng Qi
Huan Peng Qi
ZMZhi Fang Ma
Zhi Fang Ma
MXMin Xu
Min Xu
Background: To investigate the interfraction displacement and volume variation of primary thoracic esophagus carcinoma with enhanced four-dimensional computed tomography (4DCT) scanning during fractionated radiotherapy. Methods: 4DCT data sets were acquired at the time of treatment simulation and every ten fraction for each of 32 patients throughout treatment. Scans were registered to baseline (simulation) 4DCT scans by using bony landmarks. The gross tumor volumes (GTVs) were delineated on each data set. Coordinates of the GTV centroids were acquired on each respiration phase. Distance between center of the GTV contour on the simulation scan and the centers on subsequent scans were used to assess interfraction displacement between fractions. Volumes were constructed using three approaches: The GTV delineated from the maximum intensity projection (MIP) was defined IGTVMIP, all 10 GTVs were combined to form IGTV10, GTVmean was the average of all 10 phases of each GTV. Results: Interfraction displacement in left-right (LR), anterior-posterior (AP), superior-inferior (SI) directions and 3D vector were 0.13 ± 0.09 cm, 0.16 ± 0.12 cm, 0.34 ± 0.26 cm and 0.43 ± 0.24 cm, respectively between the tenth fraction and simulation 4DCT scan. 0.14 ± 0.09 cm, 0.19 ± 0.16 cm, 0.45 ± 0.43 cm and 0.56 ± 0.40 cm in LR, AP, SI and 3D vector respectively between the twentieth fraction and simulation 4DCT scan. Displacement in SI direction was larger than LR and AP directions during treatment. For distal esophageal cancer, increased interfraction displacements were observed in SI direction and 3D vector (P = 0.002 and P = 0.001, respectively) during radiotherapy. The volume of GTVmean, IGTVMIP, and IGTV10 decreased significantly at the twentieth fraction for middle (median: 34.01%, 33.09% and 28.71%, respectively) and distal (median: 22.76%, 25.27% and 23.96%, respectively) esophageal cancer, but for the upper third, no significant variation were observed during radiotherapy. Conclusions: Interfractional displacements in SI direction were larger than LR and AP directions. For distal location, significant changes were observed in SI direction and 3D vector during radiotherapy. For middle and distal locations, the best time to reset position should be selected at the twentieth fraction when the primary tumor target volume changed significantly, and it was preferable to guide target correction and planning modification.

1 January 2019 in Technology in Cancer Research & Treatment
Verified
Journal Article
Open access
PDF file
WWWei Wang
Wei Wang
TYTing Yu
Ting Yu
MXMin Xu
Min Xu
QSQian Shao
Qian Shao
YZYingjie Zhang
Yingjie Zhang
JLJianbin Li
Jianbin Li
To compare differences in setup error assessment and correction between planar kilovolt images and cone beam computed tomography images for external beam partial breast irradiation during free breathing. Nineteen patients who received external beam partial breast irradiation after breast-conserving surgery were recruited. Interfraction setup error was acquired using planar kilovolt images and cone beam computed tomography. After online setup correction, the residual error was calculated, and the setup error was compared. The residual error and setup margin were quantified for planar kilovolt and cone beam computed tomography images. The largest setup error was observed in the anteroposterior direction for both cone beam computed tomography and planar kilovolt imaging (−1.45 mm, 1.74 mm). The cone beam computed tomography–based setup error (systematic error [Σ]) was less than the planar kilovolt images based on Σ in the anteroposterior direction (–1.2 mm vs 2.00 mm; P = .005), and no significant differences were observed for random error (σ) in 3 dimensions (P = .948, .376, .314). After online setup correction, cone beam computed tomography significantly reduced the residual setup error compared with planar kilovolt images in the anteroposterior direction (Σ: −0.20 mm vs 0.50 mm, P = .008; σ: 0.45 mm vs 1.34 mm, P = .002). The cone beam computed tomography–based setup margin was smaller than the planar kilovolt image-based setup margin in the anteroposterior direction (−1.39 mm vs 5.57 mm, P = .003; 0.00 mm vs 3.20 mm, P = .003). Discrepancy between the setup errors observed with planar kilovolt and cone beam computed tomography was obvious in the anteroposterior direction. Compared to cone beam computed tomography, the elapsed treatment time was smaller when the initial alignment used kilovolt planar imaging. Whether using planar kilovolt or cone beam computed tomography, residual errors can be reduced to 1.5 mm for external beam partial breast irradiation procedures.

19 March 2014 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
YDYun Ding
Yun Ding
JLJianbin Li
Jianbin Li
WWWei Wang
Wei Wang
SWSuzhen Wang
Suzhen Wang
JWJinzhi Wang
Jinzhi Wang
MXMin Xu
Min Xu
To explore the volume and localization of the internal gross target volume defined using the seroma and/or surgical clips based on the four-dimensional computed tomography (4DCT) during free-breathing. Fifteen breast cancer patients after breast-conserving surgery (BCS) were recruited for EB-PBI. On the ten sets CT images, the gross target volume formed by the clips, the seroma, both the clips and seroma delineated by one radiation oncologist and defined as GTVc, GTVs and GTVc + s, respectively. The ten GTVc, GTVs and GTVc + s on the ten sets CT images produced the IGTVc, IGTVs, IGTVc + s, respectively. The IGTV volume and the distance between the center of IGTVc, IGTVs, IGTVc + s were all recorded. Conformity index (CI), degree of inclusion (DI) were calculated for IGTV/IGTV, respectively. The volume of IGTVc + s were significantly larger than the IGTVc and IGTVs (p < 0.05). There was significant difference between the DIs of IGTVc vs IGTVc + s, the DIs of IGTVs vs IGTVc + s. There was significant difference among the CIs of IGTV/IGTV. The DIs and CIs of IGTV/IGTV were negatively correlated with their centroid distance (r < 0, p < 0.05). There were volume difference and spatial mismatch between the IGTVs delineated based on the surgical clips and seroma. The IGTV defined as the seroma and surgical clips provided the best overall representation of the ‘true’ moving GTV.