Jianbin Li

Dr. Jianbin Li

Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2011 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
PDF file
FLFeng Xiang Li
Feng Xiang Li
JLJianbin Li
Jianbin Li
YZYing Jie Zhang
Ying Jie Zhang
TLTong Hai Liu
Tong Hai Liu
STShi Yu Tian
Shi Yu Tian
CMChang Sheng Ma
Chang Sheng Ma

17 December 2020 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
FDFeng Du
Feng Du
NTNing Tang
Ning Tang
YCYuzhong Cui
Yuzhong Cui
WWWei Wang
Wei Wang
YZYingjie Zhang
Yingjie Zhang
JLJianbin Li
Jianbin Li
Purpose: We quantitatively analyzed the characteristics of cone-beam computed tomography (CBCT) radiomics in different periods during radiotherapy (RT) and then built a novel nomogram model integrating clinical features and dosimetric parameters for predicting radiation pneumonitis (RP) in patients with esophageal squamous cell carcinoma (ESCC). Methods: At our institute, a retrospective study was conducted on 96 ESCC patients for whom we had complete clinical feature and dosimetric parameter data. CBCT images of each patient in three different periods of RT were obtained, the images were segmented using both lungs as the region of interest (ROI), and 851 image features were extracted. The least absolute shrinkage selection operator (LASSO) was applied to identify candidate radiomics features, and logistic regression analyses were applied to construct the rad-score. The optimal period for the rad-score, clinical features, and dosimetric parameters were selected to construct the nomogram model and then the receiver operating characteristic (ROC) curve was used to evaluate the prediction capacity of the model. Calibration curves and decision curves were used to demonstrate the discriminatory and clinical benefit ratios, respectively. Results: The relative volume of total lung treated with ≥5 Gy (V5), mean lung dose (MLD), and tumor stage were independent predictors of RP and were finally incorporated into the nomogram. When the three time periods were modeled, the first period was better than the others. In the primary cohort, the area under the ROC curve (AUC) was 0.700 (95% confidence interval (CI) 0.568–0.832), and in the independent validation cohort, the AUC was 0.765 (95% CI 0.588–0.941). In the nomogram model that integrates clinical features and dosimetric parameters, the AUC in the primary cohort was 0.836 (95% CI 0.700–0.918), and the AUC in the validation cohort was 0.905 (95% CI 0.799–1.000). The nomogram model exhibits excellent performance. Calibration curves indicate a favorable consistency between the nomogram prediction and the actual outcomes. The decision curve exhibits satisfactory clinical utility. Conclusion: The radiomics model based on early lung CBCT is a potentially valuable tool for predicting RP. V5, MLD, and tumor stage have certain predictive effects for RP. The developed nomogram model has a better prediction ability than any of the other predictors and can be used as a quantitative model to predict RP.

2 May 2013 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
WWWei Wang
Wei Wang
JLJianbin Li
Jianbin Li
HHHong Guang Hu
Hong Guang Hu
FLFeng Xiang Li
Feng Xiang Li
MXMin Xu
Min Xu
JLJie Lu
Jie Lu
Purpose: The purpose of this study was to explore the correlation between the respiration-induced target motion and volume variation with the dosimetric variance on breast and organ at risk (OAR) during free breathing. Methods and materials: After breast-conserving surgery, seventeen patients underwent respiration-synchronized 4DCT simulation scans during free breathing. Treatment planning was constructed using the end inspiration scan, then copied and applied to the other phases and the dose distribution was calculated separately to evaluate the dose-volume histograms (DVH) parameters for the planning target volume (PTV), ipsilateral lung and heart. Results: During free breathing, the treated breast motion vector was 2.09 ± 0.74 mm, and the volume variation was 3.05 ± 0.94%. There was no correlation between the breast volume and target/OAR dosimetric variation (|r| = 0.39 ~ 0.48). In the anteroposterior, superoinferior and vector directions, breast movement correlated well with the mean PTV dose, conformal index, and the lung volume receiving high dose (|r| = 0.651-0.975); in the superoinferior and vector directions, breast displacement only correlated with the heart volume receiving >5 Gy (V5) (r = −0.795, 0.687). The lung volume and the lung volume receiving high dose correlated reasonably well (r = 0.655 ~ 0.882), and a correlation only existed between heart volume and V5 (r = −0.701). Conclusion: Target movement correlated well with the target/OAR dosimetric variation in certain directions, indicating that whole breast IMRT assisted by breathing control or respiratory-adapted gated treatment promotes the accuracy of dose delivery during radiotherapy. During free breathing, the effect of breast volume variation can be ignored in whole breast IMRT.

10 July 2020 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
JSJingzhen Shi
Jingzhen Shi
YZYingjie Zhang
Yingjie Zhang
JWJinzhi Wang
Jinzhi Wang
JLJianbin Li
Jianbin Li
ZLzhenxiang li
zhenxiang li
Objective: The aim of this study was to evaluate the safety and efficacy of anlotinib combined with chemoradiotherapy for treating esophageal squamous cell carcinoma (ESCC) using patient-derived xenografts (PDXs).Methods: PDX-bearing mice were randomly divided into five groups, as follows: control group receiving normal saline, the group receiving radiotherapy, the group receiving cisplatin combined with radiotherapy, the group receiving anlotinib combined with radiotherapy, and the group receiving anlotinib, and cisplatin combined with radiotherapy. Tumor volumes and body weights were measured three times weekly for 2 weeks. The PDXs were initially assessed by comparing the histology of the original patient tumor tissues with that of the corresponding serially passaged xenografts by hematoxylin and eosin (H&E) and P63 staining. Then, expression of Bax, c-PARP, PCNA, and CD31 was detected using immunohistochemistry, and apoptosis was detected by a TUNEL assay. Cytokines released into plasma were analyzed using protein chip technology. Finally, two case studies of ESCC patients were presented to further verify the results observed in the PDX models.Results: The pathological characteristics of the serially passaged patient tumor-derived xenografts established in our study were in line with those of the original ESCC patient samples. The group receiving anlotinib and cisplatin plus radiotherapy exhibited the strongest antitumor response among the groups. Moreover, the ideal anticancer effects of anlotinib combined with chemoradiotherapy observed in clinical patients were consistent with the results observed in the PDX models, and no serious side effects were observed during treatment.Conclusions: Combination therapy with anlotinib and chemoradiotherapy may be an effective regimen for the treatment of advanced ESCC.

1 February 2015 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
JWJin-Zhi Wang
Jin-Zhi Wang
JLJianbin Li
Jianbin Li
WWWei Wang
Wei Wang
HQHuan-Peng Qi
Huan-Peng Qi
ZMZhi-Fang Ma
Zhi-Fang Ma
MXMin Xu
Min Xu

5 April 2013 in Journal of Radiation Research
Verified
Journal Article
Open access
PDF file
FLFengxing Li
Fengxing Li
JLJianbin Li
Jianbin Li
YZYingjie Zhang
Yingjie Zhang
MXMin Xu
Min Xu
DSDongping Shang
Dongping Shang
QSQian Shao
Qian Shao
The aim of this study was to explore the characteristic of 3DCT scanning phases and estimate the comparative amount of respiration motion information included in 3DCT and 4DCT by comparing the volumetric and positional difference between the volumes from 3DCT and 4DCT for the radiotherapy of non-small-cell lung cancer (NSCLC). A total of 28 patients with NSCLC sequentially underwent 3DCT and 4DCT simulation scans of the thorax during free breathing. The 4DCT images with respiratory signal data were reconstructed and sorted into 10 phases throughout a respiratory cycle. GTV-3D from 3DCT, GTV-0%, GTV-20%, GTV-50% and GTV-70% from end-inspiration, mid-expiration, end-expiration and mid-inspiration of 4DCT, and the internal GTV (IGTV-10) from the fused phase of 4DCT were delineated based on the 50% phase image, respectively. The differences in the position, size, matching index (MI) and degree of inclusion (DI) for different volumes were evaluated. The variation in the centroid shifts of GTV-0% and GTV-3D, GTV-20% and GTV-3D, GTV-50% and GTV-3D, and GTV-90% and GTV-3D in the 3D direction was not significant (P = 0.990). The size ratios of GTV-0%, GTV-20%, GTV-50%, GTV-70% and IGTV-10 to GTV-3D were 0.94 ± 0.18, 0.95 ± 0.18, 0.98 ± 0.15, 1.00 ± 0.18 and 1.60 ± 0.55, respectively. DIs of GTV-3D in IGTV-10, and IGTV-10 in GTV-3D were 0.88 ± 0.14 and 0.59 ± 0.16 (P < 0.001). The 3DCT scanning phases are irregular. The CTV-to-ITV expansion should be isotropic when defining the ITV on the 3DCT. The internal GTV derived from 4DCT cannot completely include the GTV from 3DCT. An additional margin may be required when defining the ITV-based 4DCT.