Xingbo Yao

Dr. Xingbo Yao

Student
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
JWJinming Wang
Jinming Wang
JDJialu Dai
Jialu Dai
WGWeijun Gao
Weijun Gao
XYXingbo Yao
Xingbo Yao
BDBart Julien Dewancker
Bart Julien Dewancker
JZJiayi Zeng
Jiayi Zeng
Environmental challenges like resource depletion, climate change, and biodiversity loss require human action. Environmental education influences individuals’ understanding and motivates responsible behavior, making it a real solution to address current problems. In this study, we examine the impact of situational environmental education and daily environmental education on tourists’ responsible environmental behavior by incorporating them as covariates into an integrated tourist behavior model. In total, 2381 valid questionnaires were obtained. The results showed that (1) daily environmental education mainly affects tourists’ responsible environmental behavior through attitude (0.467) and habits (0.634); (2) tourists’ responsible environmental behavior is mainly affected by situational environmental education through habits (0.534), subjective norms (0.504), and intention (0.614); and (3) personal factors, including attitudes toward environmental behavior, subjective norms, and perceptual behavior control, positively influence tourists’ responsible environmental behavioral intention and their responsible environmental behavior. This research will help to improve sustainability indicators and frameworks and to promote the adoption of sustainable tourism practices.

20 October 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
XYXingbo Yao
Xingbo Yao
BDBart Julien Dewancker
Bart Julien Dewancker
Yuang GuoYuang Guo
Yuang Guo
SHShuo Han
Shuo Han
XJXu Juan
Xu Juan
China’s research on and specific implementation of energy saving for buildings are mainly concentrated in urban areas, but according to 2016 statistics, the rural population accounts for 42.65% of the total population, so rural housing has considerable energy-saving potential. However, the degree of attention to the energy consumption of rural houses needs to be improved. Regarding the research on and implementation of passive energy-saving strategies for residences, compared with centralized urban high-rise residences, rural residences mainly have independent courtyards, with a flexible layout and easier transformation. In this study, a system that uses the common cold lanes in traditional villages and buildings’ exterior walls was constructed, and the indoor spaces of courtyard buildings in southern Shaanxi were completely passively cooled in summer. This system can be completely separated from the supply of artificial energy by relying on the accumulation and buoyancy effects of air in patios and cold lanes and the hot-pressure ventilation in buildings to cool the buildings and greatly improve indoor ventilation efficiency. As the building is ventilated and cooled, the air wall formed in the system can effectively prevent direct contact between the outdoor and indoor temperatures and reduce the impact of thermal wall radiation on the interior. In previous studies on the passive design of courtyard houses, scholars considered the effect of thermal wall radiation on indoor temperature in simulations. Therefore, in this study, we also separately calculated whether to consider the difference between the situation with and without wall heat radiation (WHR) when simulating thermal conversion. The final results show that when the cooling system was adopted, the annual cooling load of the whole building was 4786.494 kW·h without WHR. However, with WHR, the cooling load reduction was 2989.128 kW·h, a difference of 1797.336 kW·h.

XYXingbo Yao
Xingbo Yao
SHShuo Han
Shuo Han
BDBart Julien Dewancker
Bart Julien Dewancker
Using wind speed, wind direction, and turbulence intensity values as evaluation indicators, the ventilation performance of villages with complex building layouts was studied. We used the SKE, RNG, and RKE solvers in CFD-3D steady-state Reynolds-averaged Navier–Stokes (RANS) to simulate the wind environment of a village. The findings show that for the simulation of rural wind environments with complex building layouts, steady-state simulation solvers need to be evaluated in detail to verify their accuracy. In this study, a village with a complex architectural layout in Southern Shaanxi, China, was taken as the research object, and three steady-state simulation solvers were used to evaluate the ventilation performance of the village. The simulated data were compared with the measured data to find the most suitable solver for this kind of village wind environment simulation. The results show that for the simulation of the village wind environment with a complex building layout, the RNG simulation results have the lowest reliability among the three steady-state solvers. The reliability of wind speed distribution and turbulence intensity distribution are 0.7881 and 0.2473, respectively. However, the wind speed and turbulence intensity values obtained by the SKE solver are the closest to the measured values, which are 0.8625 and 0.9088, respectively. Therefore, for villages with complex building layouts, the SKE solver should be the first choice for simulating wind environment distribution. When using the RNG solver, the overall turbulence intensity value obtained is higher than the measured value. The average deviation between the simulated data and SKE and RKE at a height of 1.7 m is 42.61%. The main reason for this is that RNG overestimates the vortices and underestimates the airflow rate in the building intervals.

18 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
XYXingbo Yao
Xingbo Yao
SHShuo Han
Shuo Han
BDBart Julien Dewancker
Bart Julien Dewancker
China’s rural houses are mostly courtyard-style independent houses. Such houses have certain characteristics, e.g., small mutual influences between houses, strong transformation flexibility, and an easier approach to using the natural environment to develop passive energy-saving characteristics. Therefore, rural houses have large energy-saving potential. In this study, for the first time, the cold alleys between buildings were used as an energy source for passive cooling and ventilation. Traditional houses in Shuhe, China, were used as a case study. The cold alleys in the settlements were used to compensate for the natural conditions in summer, and the cold air in the cold alley was introduced into each room using hot-press ventilation and by employing an accumulation effect from a corresponding patio. The room was ventilated and cooled, and air ducts were used to connect the rooms on both sides of the patio to improve the cooling efficiency. The research variables included the existence or non-existence of wall heat radiation (WHR), and the importance and influence of the WHR on the indoor conditions were verified. The cold air trapped in the new system formed an air partition wall, effectively blocking the direct influence of solar radiation on the room, reducing the heat transfer rate of the residential wall, and consuming part of the heat. In winter, based on using air ducts as supporting members, a glass roof was added to the patio, which improved the heat storage capacity of the patio and turned it into a constant-temperature heater for heating the building interior. Based on calculations, in the new system without WHR, the annual cooling load reduction was 55,417.33 kWh. With WHR, the annual cooling load reduction was 28,537.57 kWh. The annual cooling load of the air insulation wall of the new system was reduced to 1133.7 kWh. In winter, using the glass roof to increase the heat storage capacity of the patio reduced the heating load to 54,537.78 kWh.