Krystyna KOSTYRKO

Prof. Dr. Krystyna KOSTYRKO

orcid

Research Focus & Metrics

Academic Career Length

51Years (1976-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2017 in Journal of Building Physics
Verified
Journal Article
Closed access
Michał PiaseckiMichał Piasecki
Michał Piasecki
KKKrystyna KOSTYRKO
Krystyna KOSTYRKO
SPSławomir Pykacz
Sławomir Pykacz
Indoor environment quality is a relative measure of comfort perception by people exposed to the indoor conditions. It is expected that any assessment of energy performance should also include indoor comfort. This study is to review indoor environmental quality models (with respect to thermal and acoustic comfort, indoor air and lighting quality). A simplified indoor environmental quality model is also developed with consideration of EN 15251 draft ‘Guideline for using indoor environmental input parameters for the design and assessment of energy performance of buildings’. This article analyses what components should be modelled and in particular discusses the effect of different weighting schemes on the overall indoor environmental quality index. The analysis includes thermal comfort models, indoor air quality, acoustic comfort and daylight illumination versus lightning. The proposed indoor environmental quality component sub-models will give the most reliable results when the model indoor environment input data are correctly measured and disturbing influences of indoor environmental quality monitoring process are well defined and properly assessed. The final indoor environmental quality result is based on subjoining the uncertainty values achieved in panel analysis of percentage of persons dissatisfied with indoor environmental quality with corrected measurement uncertainty. All simulations for IEQindex sub-components and preliminary metrological analysis of the whole indoor environmental quality model were performed with the NIST program for Monte Carlo tests. The presented indoor environmental quality model proposal is developed to support engineers’ practice as the convenient tool for a practical assessment of building’s occupational satisfaction.

16 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
Michał PiaseckiMichał Piasecki
Michał Piasecki
KKKrystyna KOSTYRKO
Krystyna KOSTYRKO
When planning the energy demand of ventilation, proper consideration should be given to the possible scenarios of indoor air quality and pollutant concentrations. The purpose of the present research is to create a practical method of prioritising indoor air pollutants, considering technical, economical and health aspects, in the Indoor Air Quality model (IAQ). In order to find the global weights for the combined IAQindex model sub-elements (in practice, air pollutant concentrations), the Multi-Criteria Decision Making (MCDM) approach is used. The authors have approached the problem of a weighting scheme in a model such as the complex model of the IAQ related to making decisions with many criteria and with the Multi-Attribute Decision Making MADM approach (specifically MCDM). The basis of the MADM method is a decision matrix constructed rationally by the authors, which includes six attributes: actual indoor air carbon dioxide concentration, total volatile organic compounds (TVOCs) and formaldehyde HCHO concentration, and their anthropogenic and construction product emissions to the indoor environment. The decision model of IAQindex includes five alternatives (possible situations), and the combination of pollutant concentration attributes with additional emission attributes is related to the indoor environment under specific situation. For defining the weights of criteria, the authors provide objective approaches: (i) entropy-based approach considering measuring the amount of information, and (ii) CRITIC, a statistic-based approach. The value of the presented method, i.e., the determination of global weights for IAQ components, is shown as a practical application to determine IAQ and the Indoor Environmental Quality (IEQ) index for an office building used as a case study.

26 October 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
Michał PiaseckiMichał Piasecki
Michał Piasecki
Mateusz KozickiMateusz Kozicki
Mateusz Kozicki
Szymon FirlągSzymon Firląg
Szymon Firląg
AGAnna Goljan
Anna Goljan
KKKrystyna KOSTYRKO
Krystyna KOSTYRKO
The article analyzes the impact of measured concentrations of Total Volatile Organic Compounds (TVOC) emissions determined for four BREEAM certified buildings on the Indoor Air Quality Index (IAQindex) and the overall Indoor Environment Quality index (IEQindex). The IEQindex indicates the percentage of building users who are satisfied from the indoor environment. In existing IEQ models, currently the concentration of CO2 is mostly used to evaluate the IAQindex sub-component. Authors point out that it is recommended to use TVOC instead CO2 at pre-occupant stage where building is mainly polluted by emission from finishing products. The research provides the approach where the component related to the emission of TVOCs is implemented to IEQ model. The first stage of assessment was a test of the volatile organic compounds concentrations in case study buildings. Secondly, the analysis results were assigned into the number of dissatisfied users (PD(IAQ)) from the theoretical function given by Jokl-Fanger resulting from the Weber-Fechner equation. Finally, the overall IEQindex was calculated. The IEQ approach proposed in this paper is mainly based on a consideration of EN 15251 and scientifically accepted models.

20 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
Michał PiaseckiMichał Piasecki
Michał Piasecki
KKKrystyna KOSTYRKO
Krystyna KOSTYRKO
Małgorzata Fedorczak-CisakMałgorzata Fedorczak-Cisak
Małgorzata Fedorczak-Cisak
KNKatarzyna Nowak
Katarzyna Nowak
The authors studied the impact of indoor air humidity in the range of 60% to 90% on building user perception in the temperature range of 26 to 28 °C. The research thesis was put forward that the impact of humidity on indoor air quality dissatisfaction of building users in a warm and humid indoor environment is greater than that indicated in thermal comfort models. The presented experiment examined the indoor air quality perception of n = 28 subjects in the test chamber of a nearly zero energy building under ten environmental conditions, together with a thermal comfort assessment. The authors developed an experimental relation for predicting building users’ satisfaction based on the Weber–Fechner law, where the predicted percentage of dissatisfied users (PD) is determined by means of air enthalpy (h), PD = f(h). The obtained results confirmed the sated thesis. Additionally, the intersection points of the experimental function and isotherms resulting from the Fanger model are presented, where the thermal comfort assessment starts to indicate lower user dissatisfaction results than experimental values. The authors recommend the experimental equation for humid air enthalpies in the range of 50 to 90 kJ/kg. The indoor air quality assessment based on the enthalpy value is simple and can be used to determine the overall Indoor Environmental Quality index of a building (IEQindex).

5 February 2018 in Journal of Building Physics
Verified
Journal Article
Closed access
Michał PiaseckiMichał Piasecki
Michał Piasecki
KKKrystyna KOSTYRKO
Krystyna KOSTYRKO
Indoor environmental quality index involves a set of indoor environmental quality sub-components, provides an assessment of building user comfort and satisfaction and may be used as a tool to support the design of energy-efficient buildings. Unfortunately, the unknown reliability of the indoor environmental quality model is a recognized barrier for its wider practical use. In this article, a preliminary reliability test for the indoor environmental quality model is presented, providing a correct evaluation of the measurement data results and a step-by-step guide to the expression of its uncertainty. The uncertainty based on the physical parameters is first analyzed and then corrected by considering the impacts of the instability of the physical parameters. In the end, all sources of uncertainty are recognized, including uncertainties introduced by the probability distribution of panel sensory tests. A procedure for detecting internal incongruity in the indoor environmental quality model structure is also provided, and a criterion for elimination of this syndrome is proposed. Finally, in standardized indoor environment, the estimated uncertainty of the IEQindex is presented to be no less than ±17%.

18 September 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Michał PiaseckiMichał Piasecki
Michał Piasecki
KKKrystyna KOSTYRKO
Krystyna KOSTYRKO
Indoor air quality (IAQ) is one of the most important elements affecting a building user’s comfort and satisfaction. Currently, many methods of assessing the quality of indoor air have been described in the literature. In the authors’ opinion, the methods presented have not been collected, systematized, and organized into one multi-component model. The application purpose of the assessment is extremely important when choosing IAQ model. This article provides the state-of-the-art overview on IAQ methodology and attempts to systematize approach. Sub-models of the processes that impact indoor air quality, which can be distinguished as components of the IAQ model, are selected and presented based on sensory satisfaction functions. Subcomponents of three potential IAQ models were classified according to their application potential: IAQ quality index, IAQ comfort index, and an overall health and comfort index. The authors provide a method for using the combined IAQ index to determine the indoor environmental quality index, IEQ. In addition, the article presents a method for adjusting the weights of particular subcomponents and a practical case study which provides IAQ and IEQ model implementation for a large office building assessment (with a BREEAM rating of excellent).