Philip Gardiner

Dr. Philip Gardiner

Ulster University, School of Biomedical Sciences, UK
+1
orcid

Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
VVVini Vijayan
Vini Vijayan
JCJames P. Connolly
James P. Connolly
Joan CondellJoan Condell
Joan Condell
NMNigel McKelvey
Nigel McKelvey
Philip GardinerPhilip Gardiner
Philip Gardiner
Wearable sensor technology has gradually extended its usability into a wide range of well-known applications. Wearable sensors can typically assess and quantify the wearer’s physiology and are commonly employed for human activity detection and quantified self-assessment. Wearable sensors are increasingly utilised to monitor patient health, rapidly assist with disease diagnosis, and help predict and often improve patient outcomes. Clinicians use various self-report questionnaires and well-known tests to report patient symptoms and assess their functional ability. These assessments are time consuming and costly and depend on subjective patient recall. Moreover, measurements may not accurately demonstrate the patient’s functional ability whilst at home. Wearable sensors can be used to detect and quantify specific movements in different applications. The volume of data collected by wearable sensors during long-term assessment of ambulatory movement can become immense in tuple size. This paper discusses current techniques used to track and record various human body movements, as well as techniques used to measure activity and sleep from long-term data collected by wearable technology devices.

1 October 1994 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
Philip GardinerPhilip Gardiner
Philip Gardiner
CWChronic Ward
Chronic Ward
HBH Booth
H Booth
AAA Allison
A Allison
DHD J Hendrick
D J Hendrick
EWE H Walters
E H Walters
Using BAL, we studied the effects of 8 wk of treatment with salmeterol on airway inflammation in nine asthmatic subjects in a double-blind crossover placebo-controlled protocol. The study patients were all receiving regular inhaled corticosteroid therapy (400 to 1,000 micrograms beclomethasone dipropionate per day) and inhaled albuterol for symptomatic relief, i.e., subjects who might be considered suitable for treatment with salmeterol. The asthmatic group had significant differences in numbers of epithelial cells and eosinophils in BAL compared with a group of 15 normal control subjects (p < 0.01). During salmeterol treatment mean morning and evening peak flow rates were increased (p < 0.05). There was no significant change in BAL cell profile and no change in percentages of CD4 and CD8 lymphocytes or proportion of lymphocytes expressing HLA-DR after salmeterol. In conclusion, we were unable to demonstrate any significant anti-inflammatory effect of regular salmeterol therapy on airway inflammation using BAL in these asthmatic patients. At the same time, there was equally no evidence of a deterioration in the underlying inflammatory disease process.

22 November 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JCJames Connolly
James Connolly
JCJoan Condell
Joan Condell
BOBrendan O'Flynn
Brendan O'Flynn
JSJavier Torres Sanchez
Javier Torres Sanchez
Philip GardinerPhilip Gardiner
Philip Gardiner
Arthritis remains a disabling and painful disease, and involvement of finger joints is a major cause of disability and loss of employment. Traditional arthritis measurements require labour intensive examination by clinical staff. These manual measurements are inaccurate and open to observer variation. This paper presents the development and testing of a next generation wireless smart glove to facilitate the accurate measurement of finger movement through the integration of multiple IMU sensors, with bespoke controlling algorithms. Our main objective was to measure finger and thumb joint movement. These dynamic measurements will provide clinicians with a new and accurate way to measure loss of movement in patients with Rheumatoid Arthritis. Commercially available gaming gloves are not fitted with sufficient sensors for this particular application, and require calibration for each glove wearer. Unlike these state-of-the-art data gloves, the Inertial Measurement Unit (IMU) glove uses a combination of novel stretchable substrate material and 9 degree of freedom (DOF) inertial sensors in conjunction with complex data analytics to detect joint movement. Our novel iSEG-Glove requires minimal calibration and is therefore particularly suited to the healthcare environment. Inaccuracies may arise for wearers who have varying degrees of movement in their finger joints, variance in hand size or deformities. The developed glove is fitted with sensors to overcome these issues. This glove will help quantify joint stiffness and monitor patient progression during the arthritis rehabilitation process.

1 July 1995 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
HBH Booth
H Booth
IRI Richmond
I Richmond
CWChronic Ward
Chronic Ward
Philip GardinerPhilip Gardiner
Philip Gardiner
RHR Harkawat
R Harkawat
EWE H Walters
E H Walters
Inhaled corticosteroids are now first-line therapy for most patients with asthma. However, it has been shown that there is ongoing airway inflammation and airway hyperresponsiveness even in the presence of low dose inhaled corticosteroids. To ensure a maximal therapeutic potential we investigated the effect of 3 mo of a very high dose of a new inhaled corticosteroid, fluticasone propionate (FP) (equivalent to 4,000 micrograms daily of beclomethasone dipropionate [BDP]. Twenty asthmatics with mild-to-moderate disease were recruited into this single-blind study. Baseline data were compared with those from 26 normal subjects. Differences in inflammatory indices between asthmatics and normal subjects were detected in both BAL and endobronchial biopsies. After the FP treatment period there was a significant improvement in symptom scores, lung function, and airway responsiveness by a mean 2.8 doubling dilutions of methacholine. Reduction in the airway lymphocyte load and lymphocyte activation was demonstrated and is likely to be an important mechanism mediating the effects of inhaled corticosteroids. Decreased mast cell numbers and activity in atopic asthma suggest that corticosteroids may have additional targets in different types of asthma. Reduced lymphocyte and mast cell activity was found with high dose FP even in those receiving low dose maintenance BDP prior to the study, suggesting a dose-response effect of inhaled corticosteroids on airway inflammation. BAL eosinophilia was still present after FP, indicative of a component of asthmatic airway inflammation that is relatively resistant to corticosteroid therapy.

30 January 2017 in RMD Open
Verified
Journal Article
Open access
PDF file
RFRoy M Fleischmann
Roy M Fleischmann
DHDésirée van der Heijde
Désirée van der Heijde
Philip GardinerPhilip Gardiner
Philip Gardiner
ASAnnette Szumski
Annette Szumski
LMLisa Marshall
Lisa Marshall
EBEustratios Bananis
Eustratios Bananis
Background In most patients with rheumatoid arthritis (RA), Disease Activity Score 28-joint count C reactive protein (DAS28-CRP) is lower than DAS28 erythrocyte sedimentation rate (DAS28-ESR), suggesting that use of the DAS28-ESR cut-off to assess high disease activity (HDA) with DAS28-CRP may underestimate the number of patients with HDA. We determined the DAS28-CRP value corresponding to the validated DAS28-ESR cut-off for HDA. Methods Baseline data were pooled from 2 clinical studies evaluating etanercept (ETN) plus methotrexate (MTX) or MTX in early RA; DAS28-CRP and DAS28-ESR were obtained, allowing the determination of the DAS28-CRP HDA value best corresponding to the DAS28-ESR cut-off of >5.1. Results At baseline, as expected, fewer patients had HDA by DAS28-CRP than DAS28-ESR; DAS28-CRP>5.1 and DAS28-ESR>5.1 had only modest agreement (κ coefficients 0.45–0.54). Mean DAS28-CRP and DAS28-ESR were 5.7 and 6.2, respectively, in the ETN+MTX group (n=571), and 6.0 and 6.5 in the MTX group (n=262). A DAS28-CRP cut-off of 4.6 corresponded to a DAS28-ESR cut-off of 5.1. Conclusions We have shown that a DAS28-CRP of 4.6 corresponds to 5.1 for DAS28-ESR. Since this is substantially lower than the DAS28-ESR cut-off of 5.1, using 5.1 as the cut-off for DAS28-CRP underestimates disease activity in RA. Trial registration number NCT00195494; NCT00913458.

1 September 1991 in Thorax
Verified
Journal Article
Open access
PDF file
EWE H Walters
E H Walters
Philip GardinerPhilip Gardiner
Philip Gardiner