Joan Condell

Prof. Joan Condell

Ulster University
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
VVVini Vijayan
Vini Vijayan
JCJames P. Connolly
James P. Connolly
Joan CondellJoan Condell
Joan Condell
NMNigel McKelvey
Nigel McKelvey
Philip GardinerPhilip Gardiner
Philip Gardiner
Wearable sensor technology has gradually extended its usability into a wide range of well-known applications. Wearable sensors can typically assess and quantify the wearer’s physiology and are commonly employed for human activity detection and quantified self-assessment. Wearable sensors are increasingly utilised to monitor patient health, rapidly assist with disease diagnosis, and help predict and often improve patient outcomes. Clinicians use various self-report questionnaires and well-known tests to report patient symptoms and assess their functional ability. These assessments are time consuming and costly and depend on subjective patient recall. Moreover, measurements may not accurately demonstrate the patient’s functional ability whilst at home. Wearable sensors can be used to detect and quantify specific movements in different applications. The volume of data collected by wearable sensors during long-term assessment of ambulatory movement can become immense in tuple size. This paper discusses current techniques used to track and record various human body movements, as well as techniques used to measure activity and sleep from long-term data collected by wearable technology devices.

3 June 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
KMKevin Moore
Kevin Moore
EOEmma O'Shea
Emma O'Shea
LKLorna Kenny
Lorna Kenny
JBJohn Barton
John Barton
STSalvatore Tedesco
Salvatore Tedesco
STSuzanne Timmons
Suzanne Timmons
Background: Older adults may use wearable devices for various reasons, ranging from monitoring clinically relevant health metrics or detecting falls to monitoring physical activity. Little is known about how this population engages with wearable devices, and no qualitative synthesis exists to describe their shared experiences with long-term use. Objective: This study aims to synthesize qualitative studies of user experience after a multi-day trial with a wearable device to understand user experience and the factors that contribute to the acceptance and use of wearable devices. Methods: We conducted a systematic search in CINAHL, APA PsycINFO, PubMed, and Embase (2015-2020; English) with fixed search terms relating to older adults and wearable devices. A meta-synthesis methodology was used. We extracted themes from primary studies, identified key concepts, and applied reciprocal and refutational translation techniques; findings were synthesized into third-order interpretations, and finally, a “line-of-argument” was developed. Our overall goal was theory development, higher-level abstraction, and generalizability for making this group of qualitative findings more accessible. Results: In total, we reviewed 20 papers; 2 evaluated fall detection devices, 1 tested an ankle-worn step counter, and the remaining 17 tested activity trackers. The duration of wearing ranged from 3 days to 24 months. The views of 349 participants (age: range 51-94 years) were synthesized. Four key concepts were identified and outlined: motivation for device use, user characteristics (openness to engage and functional ability), integration into daily life, and device features. Motivation for device use is intrinsic and extrinsic, encompassing many aspects of the user experience, and appears to be as, if not more, important than the actual device features. To overcome usability barriers, an older adult must be motivated by the useful purpose of the device. A device that serves its intended purpose adds value to the user’s life. The user’s needs and the support structure around the device—aspects that are often overlooked—seem to play a crucial role in long-term adoption. Our “line-of-argument” model describes how motivation, ease of use, and device purpose determine whether a device is perceived to add value to the user’s life, which subsequently predicts whether the device will be integrated into the user’s life. Conclusions: The added value of a wearable device is the resulting balance of motivators (or lack thereof), device features (and their accuracy), ease of use, device purpose, and user experience. The added value contributes to the successful integration of the device into the daily life of the user. Useful device features alone do not lead to continued use. A support structure should be placed around the user to foster motivation, encourage peer engagement, and adapt to the user’s preferences.

20 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JHJianDong Huang
JianDong Huang
JWJinling Wang
Jinling Wang
ERElaine Ramsey
Elaine Ramsey
Gerard LeaveyGerard Leavey
Gerard Leavey
TCTimothy James Chico
Timothy James Chico
Joan CondellJoan Condell
Joan Condell
Cardiovascular disease (CVD) is the world’s leading cause of mortality. There is significant interest in using Artificial Intelligence (AI) to analyse data from novel sensors such as wearables to provide an earlier and more accurate prediction and diagnosis of heart disease. Digital health technologies that fuse AI and sensing devices may help disease prevention and reduce the substantial morbidity and mortality caused by CVD worldwide. In this review, we identify and describe recent developments in the application of digital health for CVD, focusing on AI approaches for CVD detection, diagnosis, and prediction through AI models driven by data collected from wearables. We summarise the literature on the use of wearables and AI in cardiovascular disease diagnosis, followed by a detailed description of the dominant AI approaches applied for modelling and prediction using data acquired from sensors such as wearables. We discuss the AI algorithms and models and clinical applications and find that AI and machine-learning-based approaches are superior to traditional or conventional statistical methods for predicting cardiovascular events. However, further studies evaluating the applicability of such algorithms in the real world are needed. In addition, improvements in wearable device data accuracy and better management of their application are required. Lastly, we discuss the challenges that the introduction of such technologies into routine healthcare may face.

29 December 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Tamíris Pacheco da CostaTamíris Pacheco da Costa
Tamíris Pacheco da Costa
JGJames Gillespie
James Gillespie
XCXavier Cama-Moncunill
Xavier Cama-Moncunill
SWShane Ward
Shane Ward
Joan CondellJoan Condell
Joan Condell
FMFionnuala Murphy
Fionnuala Murphy
Continuous monitoring of food loss and waste (FLW) is crucial for improving food security and mitigating climate change. By measuring quality parameters such as temperature and humidity, real-time sensors are technologies that can continuously monitor the quality of food and thereby help reduce FLW. While there is enough literature on sensors, there is still a lack of understanding on how, where and to what extent these sensors have been applied to monitor FLW. In this paper, a systematic review of 59 published studies focused on sensor technologies to reduce food waste in food supply chains was performed with a view to synthesising the experience and lessons learnt. This review examines two aspects of the field, namely, the type of IoT technologies applied and the characteristics of the supply chains in which it has been deployed. Supply chain characteristics according to the type of product, supply chain stage, and region were examined, while sensor technology explores the monitored parameters, communication protocols, data storage, and application layers. This article shows that, while due to their high perishability and short shelf lives, monitoring fruit and vegetables using a combination of temperature and humidity sensors is the most recurring goal of the research, there are many other applications and technologies being explored in the research space for the reduction of food waste. In addition, it was demonstrated that there is huge potential in the field, and that IoT technologies should be continually explored and applied to improve food production, management, transportation, and storage to support the cause of reducing FLW.

25 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
JGJames Gillespie
James Gillespie
Tamíris Pacheco da CostaTamíris Pacheco da Costa
Tamíris Pacheco da Costa
XCXavier Cama-Moncunill
Xavier Cama-Moncunill
TCTrevor Cadden
Trevor Cadden
Joan CondellJoan Condell
Joan Condell
Ramakrishnan RamanathanRamakrishnan Ramanathan
Ramakrishnan Ramanathan
There are approximately 88 million tonnes of food waste generated annually in the EU alone. Food spoilage during distribution accounts for some of this waste. To minimise this spoilage, it is of utmost importance to maintain the cold chain during the transportation of perishable foods such as meats, fruits, and vegetables. However, these products are often unfortunately wasted in large quantities when unpredictable failures occur in the refrigeration units of transport vehicles. This work proposes a real-time IoT anomaly detection system to detect equipment failures and provide decision support options to warehouse staff and delivery drivers, thus reducing potential food wastage. We developed a bespoke Internet of Things (IoT) solution for real-time product monitoring and alerting during cold chain transportation, which is based on the Digital Matter Eagle cellular data logger and two temperature probes. A visual dashboard was developed to allow logistics staff to perform monitoring, and business-defined temperature thresholds were used to develop a text and email decision support system, notifying relevant staff members if anomalies were detected. The IoT anomaly detection system was deployed with Musgrave Marketplace, Ireland’s largest grocery distributor, in three of their delivery vans operating in the greater Belfast area. Results show that the LTE-M cellular IoT system is power efficient and avoids sending false alerts due to the novel alerting system which was developed based on trip detection.

24 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Jeffrey HendersonJeffrey Henderson
Jeffrey Henderson
Joan CondellJoan Condell
Joan Condell
JCJames Connolly
James Connolly
DKDaniel Kelly
Daniel Kelly
Kevin CurranKevin Curran
Kevin Curran
Early detection of Rheumatoid Arthritis (RA) and other neurological conditions is vital for effective treatment. Existing methods of detecting RA rely on observation, questionnaires, and physical measurement, each with their own weaknesses. Pharmaceutical medications and procedures aim to reduce the debilitating effect, preventing the progression of the illness and bringing the condition into remission. There is still a great deal of ambiguity around patient diagnosis, as the difficulty of measurement has reduced the importance that joint stiffness plays as an RA identifier. The research areas of medical rehabilitation and clinical assessment indicate high impact applications for wearable sensing devices. As a result, the overall aim of this research is to review current sensor technologies that could be used to measure an individual’s RA severity. Other research teams within RA have previously developed objective measuring devices to assess the physical symptoms of hand steadiness through to joint stiffness. Unfamiliar physical effects of these sensory devices restricted their introduction into clinical practice. This paper provides an updated review among the sensor and glove types proposed in the literature to assist with the diagnosis and rehabilitation activities of RA. Consequently, the main goal of this paper is to review contact systems and to outline their potentialities and limitations. Considerable attention has been paid to gloved based devices as they have been extensively researched for medical practice in recent years. Such technologies are reviewed to determine whether they are suitable measuring tools.