Joel Clementson

Dr. Joel Clementson


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2015 in Atoms
Verified
Journal Article
Open access
PDF file
JCJoel Clementson
Joel Clementson
TLThomas Lennartsson
Thomas Lennartsson
PBPeter Beiersdorfer
Peter Beiersdorfer
The extreme ultraviolet (EUV) emission from few-times ionized tungsten atoms has been experimentally studied at the Livermore electron beam ion trap facility. The ions were produced and confined during low-energy operations of the EBIT-I electron beam ion trap. By varying the electron-beam energy from around 30–300 eV, tungsten ions in charge states expected to be abundant in tokamak divertor plasmas were excited, and the resulting EUV emission was studied using a survey spectrometer covering 120–320 Å. It is found that the emission strongly depends on the excitation energy; below 150 eV, it is relatively simple, consisting of strong isolated lines from a few charge states, whereas at higher energies, it becomes very complex. For divertor plasmas with tungsten impurity ions, this emission should prove useful for diagnostics of tungsten flux rates and charge balance, as well as for radiative cooling of the divertor volume. Several lines in the 194–223 Å interval belonging to the spectra of five- and seven-times ionized tungsten (Tm-like W VI and Ho-like W VIII) were also measured using a high-resolution spectrometer.

15 June 2015 in Atoms
Verified
Journal Article
Open access
PDF file
PBPeter Beiersdorfer
Peter Beiersdorfer
JCJoel Clementson
Joel Clementson
USUlyana I. Safronova
Ulyana I. Safronova
We give a brief overview of our recent experimental and theoretical work involving highly charged tungsten ions in high-temperature magnetically confined plasmas. Our work includes X-ray and extreme ultraviolet spectroscopy, state-of-the-art structure calculations, the generation of dielectronic recombination rate coefficients, collisional-radiative spectral modeling and assessments of the atomic data need for X-ray diagnostics monitoring of the parameters of the core plasma of future tokamaks, such as ITER. We give examples of our recent results in these areas.

21 January 2025 in Atoms
Verified
Journal Article
Open access
PDF file
JLJaan Lepson
Jaan Lepson
Gregory BrownGregory Brown
Gregory Brown
JCJoel Clementson
Joel Clementson
AFAlexander Fairchild
Alexander Fairchild
MGMing F Gu
Ming F Gu
PBPeter Beiersdorfer
Peter Beiersdorfer
Using a high-resolution grating spectrometer on the Livermore EBIT-I electron beam ion trap, we have measured three n=3,4→n=1 K-shell emission lines in lithium-like O5+, which are situated near the O VIII Lyman-α lines at 19 Å. Two of the resulting wavelengths agree well with the wavelengths of these lines we reported earlier, but the wavelength of the third line does not. In contrast, our new wavelengths now fully agree with those from resonant photo-absorption experiments on the PETRA III synchrotron facility.

27 September 2024 in Atoms
Verified
Journal Article
Open access
PDF file
JCJoel Clementson
Joel Clementson
PBPeter Beiersdorfer
Peter Beiersdorfer
Gregory BrownGregory Brown
Gregory Brown
NHNatalie Hell
Natalie Hell
Elmar TräbertElmar Träbert
Elmar Träbert
A group of EUV lines of H- and He-like ions of C provides excellent wavelength calibrations for a position-sensitive multichannel detector at a high-resolution spectrograph. We have exploited this setting for a series of spectra of highly charged Eu ions recorded at the Livermore SuperEBIT electron beam ion trap. A variation in the electron beam energy results in spectra with correspondingly staggered highest Eu ion charge states ranging from Na- through to Ni-like Eu ions. A number of spectral features can be identified from the literature, but the majority of line identifications need guidance from computations of simulated spectra on the basis of collisional-radiative models. For ions with more than two electrons in the valence shell, the typical computational results are of a markedly lower accuracy. We have applied the Flexible Atomic Code (FAC), which is capable of handling all our measured ions with reasonable accuracy. We look into the systematics of the deviation of the computed transition energies from the measured ones as a function of the electron number.