Auger processes involving the filling of holes in the valence band are thought to make important contributions to the low-energy photoelectron and secondary electron spectrum from many solids. However, measurements of the energy spectrum and the efficiency with which electrons are emitted in this process remain elusive due to a large unrelated background resulting from primary beam-induced secondary electrons. Here, we report the direct measurement of the energy spectra of electrons emitted from single layer graphene as a result of the decay of deep holes in the valence band. These measurements were made possible by eliminating competing backgrounds by employing low-energy positrons (<1.25 eV) to create valence-band holes by annihilation. Our experimental results, supported by theoretical calculations, indicate that between 80 and 100% of the deep valence-band holes in graphene are filled via an Auger transition.
We present a spectroscopic method which utilizes virtual photons to selectively measure the electronic structure of the topmost atomic layer. These virtual photons are created when incident positrons transition from vacuum states to bound surface states on the sample surface and can transfer sufficient energy to excite electrons into the vacuum. The short interaction range of the virtual photons restricts the penetration depth to approximately the Thomas-Fermi screening length. Measurements and analysis of the kinetic energies of the emitted electrons made on a single layer of graphene deposited on Cu and on the clean Cu substrate show that the ejected electrons originate exclusively from the topmost atomic layer. Moreover, we find that the kinetic energies of the emitted electrons reflect the density of states at the surface. These results demonstrate that this technique will be a complementary tool to existing spectroscopic techniques in determining the electronic structure of 2D materials and fragile systems due to the absence of subsurface contributions and probe-induced surface damage.
In this study, we describe an advanced multi-functional, variable-energy positron beam system capable of measuring the energies of multiple “positron-induced” electrons in coincidence with the Doppler-shifted gamma photon resulting from the annihilation of the correlated positron. The measurements were carried out using the unique characteristics of the digital time-of-flight spectrometer and the gamma spectrometer available with the advanced positron beam system. These measurements have resulted in (i) the first digital time-of-flight spectrum of positron annihilation-induced Auger electrons generated using coincident signals from a high-purity Ge detector and a micro-channel plate, (ii) a two-dimensional array of the energy of Doppler-broadened annihilation gamma and the time-of-flight of positron-annihilation induced Auger electrons/secondary electrons measured in coincidence with the annihilation gamma photon, and (iii) the time-of-flight spectra of multiple secondary electrons ejected from a bilayer graphene surface as a result of the impact and/or annihilation of positrons. The novelty of the gamma–electron coincidence spectroscopy has been demonstrated by extracting the Doppler-broadened spectrum of gamma photons emitted due to the annihilation of positrons exclusively with 1s electrons of carbon. The width of the extracted Doppler-broadened gamma spectrum has been found to be consistent with the expected broadening of the annihilation gamma spectrum due to the momentum of the 1s electrons in carbon.
The Fe IX spectrum features two lines in the extreme ultraviolet whose ratio has been rated among the best density diagnostics in the solar spectrum. One line is an -allowed intercombination transition at 244.909 Å, the other an -forbidden transition at 241.739 Å. Employing a medium and a high resolution spectrometer at the Livermore EBIT-I electron beam ion trap, we have observed the line pair in the laboratory for the first time. Using a CHIANTI model computation, the observed line ratio yields a value of the electron density that is compatible with typical densities in our device.
Oxygen, the third most abundant element in the universe, plays a key role in the chemistry of condensed matter and biological systems. Here, we report evidence for a hitherto unexplored Auger transition in oxides, where a valence band electron fills a vacancy in the 2s state of oxygen, transferring sufficient energy to allow electron emission. We used a beam of positrons with kinetic energies of $$\sim 1$$ eV to create O 2s holes via matter-antimatter annihilation. This made possible the elimination of the large secondary electron background that has precluded definitive measurements of the low-energy electrons emitted through this process. Our experiments indicate that low-energy electron emission following the Auger decay of O 2s holes from adsorbed oxygen and oxide surfaces are very efficient. Specifically, our results indicate that the low energy electron emission following the Auger decay of O 2s hole is nearly as efficient as electron emission following the relaxation of O 1s holes in $$\hbox {TiO}_2$$ . This has important implications for the understanding of Auger-stimulated ion desorption, Coulombic decay, photodynamic cancer therapies, and may yield important insights into the radiation-induced reactive sites for corrosion and catalysis.
1 January 2017 in Journal of Physics: Conference Series
In this paper, we present results of numerical modelling of the University of Texas at Arlington's time of flight positron annihilation induced Auger electron spectrometer (UTA TOF-PAES) using SIMION® 8.1 Ion and Electron Optics Simulator. The time of flight (TOF) spectrometer measures the energy of electrons emitted from the surface of a sample as a result of the interaction of low energy positrons with the sample surface. We have used SIMION® 8.1 to calculate the times of flight spectra of electrons leaving the sample surface with energies and angles dispersed according to distribution functions chosen to model the positron induced electron emission process and have thus obtained an estimate of the true electron energy distribution. The simulated TOF distribution was convolved with a Gaussian timing resolution function and compared to the experimental distribution. The broadening observed in the simulated TOF spectra was found to be consistent with that observed in the experimental secondary electron spectra of Cu generated as a result of positrons incident with energy 1.5 eV to 901 eV, when a timing resolution of 2.3 ns was assumed.