This paper evaluates the feasibility of using a hybrid system consisting of wind and tidal turbines connected to a microgrid for power supply to coastal communities that are isolated from a main supply grid. The case study is Stewart Island, where the cost of electricity, provided by a central diesel power station, is higher than the grid network in New Zealand. Local residents believe that reducing the consumption of diesel and having a renewable source of electricity generation are two of the island’s highest priorities. Merging a tidal energy source (predictable) with wind (unpredictable) and diesel (back-up), through a microgrid, may be a way to increase reliability and decrease the cost of generation. Several off-grid configurations are simulated using HOMER and WRPLOT software. Using two wind and four tidal turbines, plus one diesel generator for back-up, is the best design in terms of lower greenhouse gas emissions, higher renewable fraction, and reduced net present cost.
The world is increasingly turning to renewable energy sources (RES) to address climate change issues and achieve net-zero carbon emissions. Integrating RES into existing power grids is necessary for sustainability because the unpredictability and irregularity of the RES can affect grid stability and generate power quality issues, leading to equipment damage and increasing operational costs. As a result, the importance of RES is severely compromised. To tackle these challenges, traditional power systems (TPS) will have to become more innovative. Smart grids use advanced technology such as two-way communication between consumers and service providers, automated control, and real-time monitoring to manage power flow effectively. Inverters are effective tools for solving power quality problems in renewable-powered smart grids. However, their effectiveness depends on topology, control method and design. This review paper focuses on the role of multilevel inverters (MLIs) in mitigating power quality issues such as voltage sag, swell and total harmonics distortion (THD). The results shown here are through simulation studies using DC sources but can be extended to RES-integrated smart grids. The comprehensive review also examines the drawbacks of TPS to understand the importance and necessity of developing a smart power system. Finally, the paper discusses future trends in MLI control technology, addressing power quality problems in smart grid environments.
This research focuses on proposing and evaluating an optimized hybrid system of wind and tidal turbines operating as a renewable energy generating unit in New Zealand. Literature review indicates increasing worldwide investment in offshore renewable energy in recent years. Offshore energy shows a high potential as an alternative energy generation solution to that of fossil fuels. Using the capacities of wind and tidal power in renewable technologies would be a suitable alternative for fossil fuels and would help prevent their detrimental effects on the environment. It is a cost-effective procedure for the power generation sector to maximize these renewables as a hybrid system. At the design phase, turbine types appropriate to environmental conditions for an area with high wind speed and tidal flow need to be considered. When selecting which turbines should be used, horizontal or vertical axis, number and length of blades, and optimized rotational speed are all important to get maximum capacity from either the wind or tidal energy for the hybrid system. Comprehensive simulation models of the hybrid system are now being set up, using several available commercial software packages such as QBlade, Simulink, and RETScreen. Several different parameters will be required for these simulation models to run in order to test performance, capacity and efficiency of the proposed hybrid system. To decide which regions are suitable for the hybrid system, it will be necessary to analyze available wind and tide records from NIWA, and online databases such as GLOBAL ATLAS. This next phase of research will aim to create optimized scenarios for the hybrid model by considering the effect of wind and water speed on performance. After deciding which region and scenarios are suitable, it will also be necessary to evaluate the costs and returns of a hybrid system. This final phase will be performed using the RETScreen simulation model.
This paper aims to design an integrated offshore structure capable of supporting a hybrid assembly of one wind plus two tidal turbines. The monopile has been found to be a suitable foundation type as the most inexpensive solution in water depths of less than 30 m. The Cook Strait in New Zealand is an ideal location for wind and tidal renewable energy sources due to its strong winds and tidal currents. Finite element analysis was performed to determine the displacement of the structure for different types of soils using OPTUM G3. After that, a macro-element model for soil was represented, considering the monopile as a Euler–Bernoulli beam model. The results enable the finding of optimum dimensions of monopiles with allowable tilt and deflection. Based on this, the diameter, thickness, and length of the monopile can be 6, 0.083, and 60 m, respectively. The maximum load occurs in extreme wind load scenarios when wind and waves move in same direction.
Solid-state transformer (SST)-based ultra-fast charging stations (UFCSs) are emerging as a key technology in next-generation electric vehicle (EV) infrastructure, addressing the growing demand for efficient charging. Unlike traditional line-frequency transformers, SSTs offer higher energy conversion efficiency, smaller size, and better scalability. However, challenges such as control complexity and grid stability remain. This review analyzes existing SST topologies (both classical and new) and control methods, discussing their impact on system performance, and finally, it provides an outlook on future technological trends.
Grid-connected photovoltaic (PV)–battery systems require advanced control to maintain stable operation, efficient energy exchange, and minimal conversion losses under variable generation and load conditions. This study proposes a dual-loop Energy Management System (EMS) integrated with a Hybrid Grey Wolf Optimizer–Particle Swarm Optimization (GWO–PSO) algorithm for coordinated control of a low-voltage PV–battery–grid system (380 V AC, ≈800 V DC bus). The hybrid optimizer was chosen due to the limitations of standalone GWO and PSO methods, which frequently experience slow convergence and local stagnation; the integrated GWO–PSO strategy enhances both exploration and exploitation during the real-time adjustment of PI controller gains. The rapid inner loop effectively balances instantaneous power among the PV, battery, and grid, while the outer optimization loop aims to minimize the ITAE criterion to enhance transient response. Simulation outcomes validate stable DC-bus voltage regulation, quicker transitions between power import and export, and prompt power balance with deviations maintained below 2.5%, signifying reduced converter losses and improved power-sharing efficiency. The battery’s state of charge is sustained within the range of 20–80%, ensuring safe operational conditions. The proposed hybrid EMS offers faster convergence, smoother power regulation, and enhanced dynamic stability compared to standalone metaheuristic controllers, establishing it as an effective and reliable solution for grid-connected PV–battery systems.