Albertus C. den Brinker

Dr. Albertus C. den Brinker

Philips Research Laboratories, High Tech Campus 4, 5656 AE Eindhoven, The Netherlands
orcid
Independent Researcher

Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Wenjin WangWenjin Wang
Wenjin Wang
Albertus C. den BrinkerAlbertus C. den Brinker
Albertus C. den Brinker
SSSander Stuijk
Sander Stuijk
GHGerard de Haan
Gerard de Haan
This paper introduces a mathematical model that incorporates the pertinent optical and physiological properties of skin reflections with the objective to increase our understanding of the algorithmic principles behind multi-wavelength remote photoplethysmography (rPPG). The model is used to explain the different choices that were made in existing rPPG methods for pulse extraction. The understanding that comes from the model can be used to design robust or application-specific rPPG solutions. We illustrate this by the design of an alternative rPPG method where a projection plane orthogonal to the skin-tone is used for pulse extraction. A large benchmark on the various discussed rPPG methods shows that their relative merits can indeed be understood from the proposed model.

8 May 2017 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
Wenjin WangWenjin Wang
Wenjin Wang
Albertus C. den BrinkerAlbertus C. den Brinker
Albertus C. den Brinker
SSSander Stuijk
Sander Stuijk
GHGerard de Haan
Gerard de Haan
Remote photoplethysmography (rPPG) enables contactless heart-rate monitoring using a regular video camera. Objective: This paper aims to improve the rPPG technology targeting continuous heart-rate measurement during fitness exercises. The fundamental limitation of the existing (multi-wavelength) rPPG methods is that they can suppress at most n − 1 independent distortions by linearly combining n wavelength color channels. Their performance are highly restricted when more than n − 1 independent distortions appear in a measurement, as typically occurs in fitness applications with vigorous body motions. Approach: To mitigate this limitation, we propose an effective yet very simple method that algorithmically extends the number of possibly suppressed distortions without using more wavelengths. Our core idea is to increase the degrees-of-freedom of noise reduction by decomposing the n wavelength camera-signals into multiple orthogonal frequency bands and extracting the pulse-signal per band-basis. This processing, namely Sub-band rPPG (SB), can suppress different distortion-frequencies using independent combinations of color channels. Main results: A challenging fitness benchmark dataset is created, including 25 videos recorded from 7 healthy adult subjects (ages from 25 to 40 yrs; six male and one female) running on a treadmill in an indoor environment. Various practical challenges are simulated in the recordings, such as different skin-tones, light sources, illumination intensities, and exercising modes. The basic form of SB is benchmarked against a state-of-the-art method (POS) on the fitness dataset. Using non-biased parameter settings, the average signal-to-noise-ratio (SNR) for POS varies in [−4.18, −2.07] dB, for SB varies in [−1.08, 4.77] dB. The ANOVA test shows that the improvement of SB over POS is statistically significant for almost all settings (p-value <0.05). Significance: The results suggest that the proposed SB method considerably increases the robustness of heart-rate measurement in challenging fitness applications, and outperforms the state-of-the-art method.

30 August 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Wenjin WangWenjin Wang
Wenjin Wang
Albertus C. den BrinkerAlbertus C. den Brinker
Albertus C. den Brinker
GHGerard De Haan
Gerard De Haan
Near-infrared (NIR) remote photoplethysmography (PPG) promises attractive applications in darkness, as it involves unobtrusive, invisible light. However, since the PPG strength (AC/DC) is much lower in the NIR spectrum than in the RGB spectrum, robust vital signs monitoring is more challenging. In this paper, we propose a new PPG-extraction method, DIScriminative signature based extraction (DIS), to significantly improve the pulse-rate measurement in NIR. Our core idea is to use both the color signals containing blood absorption variations and additional disturbance signals as input for PPG extraction. By defining a discriminative signature, we use one-step least-squares regression (joint optimization) to retrieve the pulsatile component from color signals and suppress disturbance signals simultaneously. A large-scale lab experiment, recorded in NIR with heavy body motions, shows the significant improvement of DIS over the state-of-the-art method, whereas its principle is simple and generally applicable.

24 February 2017 in Chronic Respiratory Disease
Verified
Journal Article
Open access
RMRafael Mesquita
Rafael Mesquita
GSGabriele Spina
Gabriele Spina
FPFabio de Oliveira Pitta
Fabio de Oliveira Pitta
DDDavid Donaire
David Donaire
BDBrenda M Deering
Brenda M Deering
MSMartijn A Spruit
Martijn A Spruit
We described physical activity measures and hourly patterns in patients with chronic obstructive pulmonary disease (COPD) after stratification for generic and COPD-specific characteristics and, based on multiple physical activity measures, we identified clusters of patients. In total, 1001 patients with COPD (65% men; age, 67 years; forced expiratory volume in the first second [FEV1], 49% predicted) were studied cross-sectionally. Demographics, anthropometrics, lung function and clinical data were assessed. Daily physical activity measures and hourly patterns were analysed based on data from a multisensor armband. Principal component analysis (PCA) and cluster analysis were applied to physical activity measures to identify clusters. Age, body mass index (BMI), dyspnoea grade and ADO index (including age, dyspnoea and airflow obstruction) were associated with physical activity measures and hourly patterns. Five clusters were identified based on three PCA components, which accounted for 60% of variance of the data. Importantly, couch potatoes (i.e. the most inactive cluster) were characterised by higher BMI, lower FEV1, worse dyspnoea and higher ADO index compared to other clusters ( p < 0.05 for all). Daily physical activity measures and hourly patterns are heterogeneous in COPD. Clusters of patients were identified solely based on physical activity data. These findings may be useful to develop interventions aiming to promote physical activity in COPD.

28 February 2017 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
Wenjin WangWenjin Wang
Wenjin Wang
Albertus C. den BrinkerAlbertus C. den Brinker
Albertus C. den Brinker
SSSander Stuijk
Sander Stuijk
GHGerard de Haan
Gerard de Haan
Biometric signatures of remote photoplethysmography (rPPG), including the pulse-induced characteristic color absorptions and pulse frequency range, have been used to design robust algorithms for extracting the pulse-signal from a video. In this paper, we look into a new biometric signature, i.e., the relative pulsatile amplitude, and use it to design a very effective yet computationally low-cost filtering method for rPPG, namely “amplitude-selective filtering” (ASF). Based on the observation that the human relative pulsatile amplitude varies in a specific lower range as a function of RGB channels, our basic idea is using the spectral amplitude of, e.g., the R-channel, to select the RGB frequency components inside the assumed pulsatile amplitude-range for pulse extraction. Similar to band-pass filtering (BPF), the proposed ASF can be applied to a broad range of rPPG algorithms to pre-process the RGB-signals before extracting the pulse. The benchmark in challenging fitness use-cases shows that applying ASF (ASF+BPF) as a pre-processing step brings significant and consistent improvements to all multi-channel pulse extraction methods. It improves different (multi-wavelength) rPPG algorithms to the extent where quality differences between the individual approaches almost disappear. The novelty of the proposed method is its simplicity and effectiveness in providing a solution for the extremely challenging application of rPPG to a fitness setting. The proposed method is easy to understand, simple to implement, and low-cost in running. It is the first time that the physiological property of pulsatile amplitude is used as a biometric signature for generic signal filtering.

20 November 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Wenjin WangWenjin Wang
Wenjin Wang
Albertus C. den BrinkerAlbertus C. den Brinker
Albertus C. den Brinker
GHGerard de Haan
Gerard de Haan
Camera-based remote photoplethysmography technology (remote-PPG) has shown great potential for contactless pulse-rate monitoring. However, remote-PPG systems typically analyze face images, which may restrict applications in view of privacy-preserving regulations such as the recently announced General Data Protection Regulation in the European Union. In this paper, we investigate the case of using single-element sensing as an input for remote-PPG extraction, which prohibits facial analysis and thus evades privacy issues. It also improves the efficiency of data storage and transmission. In contrast to known remote-PPG solutions using skin-selection techniques, the input signals in a single-element setup will contain a non-negligible degree of signal components associated with non-skin areas. Current remote-PPG extraction methods based on physiological and optical properties of skin reflections are therefore no longer valid. A new remote-PPG method, named Soft Signature based extraction (SoftSig), is proposed to deal with this situation by softening the dependence of pulse extraction on prior knowledge. A large scale experiment validates the concept of single-element remote-PPG monitoring and shows the improvement of SoftSig over general purpose solutions.