Sander Stuijk

Dr. Sander Stuijk

Eindhoven University of Technology
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Wenjin WangWenjin Wang
Wenjin Wang
Albertus C. den BrinkerAlbertus C. den Brinker
Albertus C. den Brinker
SSSander Stuijk
Sander Stuijk
GHGerard de Haan
Gerard de Haan
This paper introduces a mathematical model that incorporates the pertinent optical and physiological properties of skin reflections with the objective to increase our understanding of the algorithmic principles behind multi-wavelength remote photoplethysmography (rPPG). The model is used to explain the different choices that were made in existing rPPG methods for pulse extraction. The understanding that comes from the model can be used to design robust or application-specific rPPG solutions. We illustrate this by the design of an alternative rPPG method where a projection plane orthogonal to the skin-tone is used for pulse extraction. A large benchmark on the various discussed rPPG methods shows that their relative merits can indeed be understood from the proposed model.

17 December 2015 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
WWWenjin Wang
Wenjin Wang
SSSander Stuijk
Sander Stuijk
GHGerard de Haan
Gerard de Haan
In this paper, we propose a conceptually novel algorithm, namely “Spatial Subspace Rotation” (2SR), that improves the robustness of remote photoplethysmography. Based on the assumption of 1) spatially redundant pixel-sensors of a camera, and 2) a well-defined skin mask, our core idea is to estimate a spatial subspace of skin-pixels and measure its temporal rotation for pulse extraction, which does not require skin-tone or pulse-related priors in contrast to existing algorithms. The proposed algorithm is thoroughly assessed on a benchmark dataset containing 54 videos, which includes challenges of various skin-tones, body-motions in complex illuminance conditions, and pulse-rate recovery after exercise. The experimental results show that given a well-defined skin mask, 2SR outperforms the popular ICA-based approach and two state-of-the-art algorithms (CHROM and PBV). When comparing the pulse frequency spectrum, 2SR improves on average the SNR of ICA by 2.22 dB, CHROM by 1.56 dB, and PBV by 1.95 dB. When comparing the instant pulse-rate, 2SR improves on average the Pearson correlation and precision of ICA by 47% and 65%, CHROM by 22% and 23%, and PBV by 21% and 39%. ANOVA confirms the significant improvement of 2SR in peak-to-peak accuracy. The proposed 2SR algorithm is very simple to use and extend, i.e., the implementation only requires a few lines MATLAB code.

8 September 2014 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
WWWenjin Wang
Wenjin Wang
SSSander Stuijk
Sander Stuijk
GHGerard de Haan
Gerard de Haan
Remote photoplethysmography (rPPG) techniques can measure cardiac activity by detecting pulse-induced color variations on human skin using an RGB camera. State-of-the-art rPPG methods are sensitive to subject body motions (e.g., motion-induced color distortions). This study proposes a novel framework to improve the motion robustness of rPPG. The basic idea of this paper originates from the observation that a camera can simultaneously sample multiple skin regions in parallel, and each of them can be treated as an independent sensor for pulse measurement. The spatial redundancy of an image sensor can thus be exploited to distinguish the pulse signal from motion-induced noise. To this end, the pixel-based rPPG sensors are constructed to estimate a robust pulse signal using motion-compensated pixel-to-pixel pulse extraction, spatial pruning, and temporal filtering. The evaluation of this strategy is not based on a full clinical trial, but on 36 challenging benchmark videos consisting of subjects that differ in gender, skin types, and performed motion categories. Experimental results show that the proposed method improves the SNR of the state-of-the-art rPPG technique from 3.34 to 6.76 dB, and the agreement (±1.96σ) with instantaneous reference pulse rate from 55% to 80% correct. ANOVA with post hoc comparison shows that the improvement on motion robustness is significant. The rPPG method developed in this study has a performance that is very close to that of the contact-based sensor under realistic situations, while its computational efficiency allows real-time processing on an off-the-shelf computer.

2 August 2006
Verified
Conference Paper
Closed access
AGA.H. Ghamarian
A.H. Ghamarian
MGM.C.W. Geilen
M.C.W. Geilen
SSSander Stuijk
Sander Stuijk
TBT. Basten
T. Basten
BTB.D. Theelen
B.D. Theelen
MBM.J.G. Bekooij
M.J.G. Bekooij

3 August 2006
Verified
Conference Paper
Closed access
SSSander Stuijk
Sander Stuijk
MGM. Geilen
M. Geilen
TBT. Basten
T. Basten
SDF^3 is a tool for generating random Synchronous DataFlow Graphs (SDFGs), if desirable with certain guaranteed properties like strongly connectedness. It includes an extensive library of SDFG analysis and transformation algorithms as well as functionality to visualize them. The tool can create SDFG benchmarks that mimic DSP or multimedia applications.

31 May 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AMAndreia V. Moço
Andreia V. Moço
SSSander Stuijk
Sander Stuijk
GHGerard de Haan
Gerard de Haan
Remote photoplethysmography (PPG) is an optical measurement technique with established applications in vital signs monitoring. Recently, the consensual understanding of blood volume variations (BVVs) as the origin of PPG signals was challenged, raising validity concerns about the remote SpO2methodology. Recognizing the imperative for new opto-physiological evidence, this investigation supports the volumetric hypothesis with living skin experiments and Monte Carlo simulations of remote PPG-amplitude in visible light (VIS) and infrared (IR). Multilayered models of the skin were developed to simulate the separate contributions from skin layers containing pulsatile arterioles to the PPG signal in the 450–1000 nm range. The simulated spectra were qualitatively compared with observations of the resting and compressed finger pad, and complemented with videocapillaroscopy. Our results indicate that remote PPG systems indeed probe arterial blood. Green wavelengths probe dermal arterioles while red-IR wavelengths also reach subcutaneous BVVs. Owing to stable penetration depths, the red-IR diagnostic window promotes the invariance of SpO2measurements to skin non-homogeneities.