Erdal Eroglu

Erdal Eroglu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
EİEymen İzzettinoğlu
Eymen İzzettinoğlu
EEErdal Eroglu
Erdal Eroglu
Comprehending the synergistic of surface treatments and oral environmental factors is paramount for optimizing the performance of 3D-printed dentures. This study evaluates flexural strength, hardness, roughness, and color stability of 3D-printed resins after two surface treatments and coffee thermocycling, to establish alternative polishing efficacy. Rectangular test specimens (64 × 10 × 3.3 ± 0.2 mm) were fabricated from a conventional heat-cured denture base material (Probase HC, n = 20) and four 3D-printed denture base materials (Nextdent; ND, Formlabs; FL, Senertek; ST, Powerresin; PR, n = 40 per group), resulting in a total sample size of N = 180. Specimens were randomly assigned to undergo either mechanical polishing or glazing, followed by 5000 cycles of coffee thermocycling (CTC). Color change (ΔE00) and surface roughness (Ra) were assessed both prior to and subsequent to CTC. Subsequently, the specimens were subjected to a 3-point bending test and a Vickers microhardness (VH) test. Statistical analysis of the data was performed using descriptive and analytical methods, with a significance level set at α = 0.05. The application of Vita Akzent® LC (VA) as a glaze material, while conferring supplementary protection against surface degradation during coffee thermocycling (CTC), resulted in a statistically significant increase in the initial surface roughness (Ra) values across all experimental 3D-printed groups (p < 0.05). It reduced the ΔE value of the FL group (p = 0.036) but did not have a statistically significant impact on the ΔE00 of other 3D-printed groups (p˃0.05). Additionally, VA enhanced the VH of most 3D-printed groups (p < 0.05). It improved the flexural strength of the PR and ST groups but decreased it for the FL group and had no significant effect on the ND group (p = 0.088). The mechanically polished specimens demonstrated acceptable Ra, ΔE00, and flexural strength values. However, they showed a lower VH than the glazed specimens. Glaze application resulted in improved mechanical strength and hardness for the majority of 3D-printed groups; however, its capacity to effectively reduce surface roughness and discoloration was consistently limited. Conversely, mechanical polishing maintained its beneficial effects, demonstrating clinically acceptable values across all assessed parameters. Therefore, comprehensive additional investigations are necessitated to fully elucidate the performance characteristics of glaze materials and their interactions with 3D-printed denture base materials.

29 October 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
EİEymen İzzettinoğlu
Eymen İzzettinoğlu
EEErdal Eroglu
Erdal Eroglu
High water sorption and solubility in total denture base materials are primary factors contributing to prosthetic failure, as they compromise both mechanical and aesthetic properties. This study investigated how three distinct surface treatments, varying aging protocols, and different curing parameters collectively influence the water sorption (Wsp) and solubility (Wsl) of 3D-printed denture base materials. This study evaluated the water sorption and solubility of 420 disc-shaped specimens (Ø15 × 2 ± 0,2 mm) fabricated from one conventional heat-cured acrylic resin (Probase; HC), one CAD-CAM Prepolymerized PMMA block (Bilkim; M), and one 3D-printed denture base material (Formlabs; 3DP ). All groups underwent three distinct surface treatments (mechanical polishing, Optiglaze, or Vita Akzent Glaze). The 3D-printed specimens were additionally subjected to four curing durations (10, 15, 30, 60 min) and two curing atmospheres (air and glycerin). Water sorption (Wsp) and solubility (Wsl) were assessed after three distinct aging protocols: 7 days of immersion in distilled water (Wsp-DW and Wsl-DW), 6 days of immersion in a denture cleaner (Wsp-DC and Wsl-DC), and 2000 thermocycles (Wsp-TC and Wsl-TC). Statistical analysis was conducted using non-parametric tests, as the Kolmogorov-Smirnov test revealed that the data were not normally distributed (p < 0.05). The Mann-Whitney U test was applied for comparisons between two categorical variables, while the Kruskal-Wallis test was used for three or more categories. For related groups, the Friedman test was employed. Pairwise comparisons were performed to identify specific differences among groups. All statistical analyses were conducted with significance levels set at α = 0.05 and 0.01. This study demonstrates that both manufacturing technology and surface treatment significantly influence the water sorption and solubility of dental acrylics. Conventional heat-polymerized acrylics exhibited the highest water sorption, whereas 3D-printed materials consistently showed the lowest (p < 0.01). Regarding solubility, heat-cured materials generally displayed the lowest values. Conversely, 3D-printed materials had the highest Wsl-DW and Wsl-TC, but the lowest Wsl-DC (p < 0.01). Glaze application effectively reduced both water sorption and solubility across all groups compared to mechanical polishing. Lastly, while glycerin curing of 3D-printed resins led to higher sorption but lower solubility, curing duration generally had no significant impact, with some 10-minute cured groups occasionally showing higher solubility (p < 0.01). All 3D-printed groups, irrespective of surface treatment or curing parameters, demonstrated water sorption (Wsp) and solubility (Wsl) values within the limits defined by ISO 4049 − 2019 (Wsp < 40 µg/mm³; Wsl < 7.5 µg/mm³). While glaze application effectively reduces these properties, adequate curing time and the use of a glycerin curing medium can similarly diminish solubility. However, curing duration was not found to have a statistically significant impact on water sorption.


1 January 2022 in BioMed Research International
Verified
Journal Article
Open access
PDF file
EEErdal Eroglu
Erdal Eroglu
GKGiray Kolcu
Giray Kolcu
MKMukadder İnci Başer Kolcu
Mukadder İnci Başer Kolcu
Purpose. This study compared the development of face‐to‐face (F2F) psychomotor skills vs. a modified online dental anatomy course during the COVID‐19 pandemic. Methods. The 9‐HPT is regularly applied for the students’ psychomotor skill assessment in the Faculty of Dentistry of Süleyman Demirel University. In the 2020‐21 academic year, 92.2% of students who took the dental anatomy course in distance education voluntarily participated in this study (observation group). These data were compared with 34.6% of students who applied for 9‐HPT in 2019‐2020 in F2F education (control group). The Mann–Whitney U test and t‐test were used for comparison. The significance level was taken as p < 0.05. Results. Based on the dominant hand 9‐HPT score, a positive change occurred in 81.8% of the F2F and 61.6% of the online education students. Based on both dominant and nondominant hand 9‐HPT scores, a statistically significant difference between the change in scores according to the fall/spring term measurements was observed in both F2F and distance education (p < 0.001). However, the F2F‐educated group students showed better psychomotor skill development than those exposed to the online‐educated group in 9‐HPT. The results showed statistical significance for both dominant and nondominant hands (p < 0.001). Conclusion. The F2F education is the gold standard in psychomotor skill training; however, in cases where this approach cannot be realized, practical training protocols modified for online training may contribute to the motor development of students.

25 December 2021 in Süleyman Demirel Üniversitesi Sağlık Bilimleri Dergisi
Verified
Journal Article
Closed access
PDF file
EEErdal Eroglu
Erdal Eroglu
ZDZeynep Basagaoglu Demirekin
Zeynep Basagaoglu Demirekin
MEMerve Erken
Merve Erken
Objective: To evaluate the impact of the dental anatomy course on the psychomotor skills of dental students.Material Methods: The study was carried on 121 volunteer students of the dental anatomy course. The 9-hole-peg- test (9-HPT) was used for psychomotor skills assessment at the beginner vs. experienced status (fall vs. spring terms). Test completion time in seconds (sec) was used as primary data. Dominant (DH), and non-dominant hand (N-DH), gender, academic success at the higher education admission test (GPA), and the course’s final assessment scores of training were used as variables. Data were analyzed with IBM SPSS V23. Paired samples t-test, the MANOVA test, and Spearman's rho correlation were used for statistical analyses (p<0.05).Results: The participants' DH scores improved from 20.55±2.48 to. 18.32±1.84 sec (p≤0.001), while N-DH scores improved from 22.78±2.66 to 20.52±2.52 sec (p≤0.001). Female's DH scores were 20.16 ± 2.37 vs. 17.90 ± 1.59 sec (p≤0.001), the N-DH scores were 22.40 ± 2.48 vs. 19.83 ± 1.95 sec (p≤0.001) among the fall and spring terms, respectively; while males’ DH scores were 21.30 ± 2.56 vs. 19.13 ± 2.04 sec (p≤0.001), and the N-DH scores were 23.52 ± 2.86s vs. 21.88 ± 2.95 sec (p=0.003). Females’ DH scores were better than males for fall (p=016) and spring (p≤0.001) terms, and N-DH scores were better for fall (p=027) and spring (p≤0.001) terms. Neither GPA nor 9-HPT scores affected the course’s end-of-term practical exam notes.Conclusion: The dental anatomy course significantly contributes to the psychomotor proficiency development of the students.

17 March 2023 in İnönü Üniversitesi Sağlık Hizmetleri Meslek Yüksek Okulu Dergisi
Verified
Journal Article
Open access
EEErdal Eroglu
Erdal Eroglu
UTUğur Burak Temel
Uğur Burak Temel
ZDZeynep Basagaoglu Demirekin
Zeynep Basagaoglu Demirekin
OGOsman Gürdal
Osman Gürdal
This study examines the effects of several clinical procedures that lead to dehydration on color change in natural teeth. CIE L*, a*, and b* color coordinates of maxillary incisors were measured using a spectrophotometer before and after the procedure at minute intervals of 10, 20, 30, and 1440 (24 hours). Test groups were as follows: 6 and 15 minutes of the open mouth under LED and halogen dental reflectors; control groups were evaluated in a dark environment for 6 and 15 minutes; maxillary impressions were taken with condensation and additional type impression materials. Wilcoxon signed-rank tests and Mann–Whitney U tests were used for two-group comparisons. The analyses were computed by the Friedman and Kruskal–Wallis H tests for the paired and independent groups. These tests were followed by Bonferroni posthoc corrections. Obtained color values indicate significant L* changes for all groups due to dehydration for 20 minutes after the procedure. Color changes (ΔE) were significant for 30 minutes for the perceptibility (1.2>ΔE) and 20 minutes for the acceptability threshold (2.7>ΔE). Results show that experimental protocols designed to mimic dental procedures that require mouth opening may cause temporary discoloration of natural teeth, which may cause failure during shade matching.