Per- and polyfluoroalkyl substances (PFAS) are used in various industrial products; however, they pose serious health risks. In this study, soil, soil gas, and groundwater samples were collected at a PFAS manufacturing facility in New Jersey, USA, to determine the presence and distribution of PFASs from the soil surface to groundwater and at various distances from the presumed source. Fluorotelomer alcohols (FTOHs) were detected in soil (< 0.26-36.15 ng/g) and soil gas (160-12,000 E µg/m3), while perfluorinated carboxylic acids (PFCAs) were found in soil (4.3-810 ng/g), soil gas (<0.10-180 µg/m3), and groundwater (37-49 µg/L). FTOH and PFCA concentrations decreased as the distance from the presumed source increased, suggesting that PFCAs are likely to migrate in groundwater, whereas FTOHs primarily move in the vapor phase. The presence of PFAS in the groundwater, soil, and soil gas samples indicate its potential for vapor intrusion; thus, some PFAS may contribute to indoor air inhalation exposure. To the best of our knowledge, this is the first report on the quantification of volatile PFAS in soil gas at a PFAS manufacturing facility.
Subsurface contamination can migrate upward into overlying buildings, exposing the buildings’ inhabitants to contaminants that can cause detrimental health effects. This phenomenon is known as vapor intrusion (VI). When evaluating a building for VI, one must understand that seasonal and short-term variability are significant factors in determining the reasonable maximum exposure (RME) to the occupants. RME is a semi-quantitative term that refers to the lower portion of the high end of the exposure distribution—conceptually, above the 90th percentile exposure but less than the 98th percentile exposure. Samples were collected between December 2020 and April 2022 at six non-residential commercial buildings in Fairbanks, Alaska. The types of samples collected included indoor air (IA); outdoor air; subslab soil gas; soil gas; indoor radon; differential pressure; indoor and outdoor temperature; heating, ventilation, and air conditioning (HVAC) parameters; and other environmental factors. The buildings in close proximity to the volatile organic compound (VOC) source/release points presented less variability in indoor air concentrations of trichloroethylene (TCE) and tetrachloroethylene (PCE) compared to the buildings farther down gradient in the contaminated groundwater plume. The VOC data pattern for the source area buildings shows an outdoor air temperature-dominated behavior for indoor air concentrations in the summer season. HVAC system operations had less influence on long-term indoor air concentration trends than environmental factors, which is supported by similar indoor air concentration patterns independent of location within the plume. The use of soil temperature and indoor/outdoor temperatures as indicators and tracers (I&Ts) across the plume as predictors of the sampling period could produce a good estimation of the RME for the building occupants. These results, which show the use of soil temperature and indoor/outdoor temperatures as I&Ts, will help advance investigative methods for evaluation of VI in similar settings and thereby improve the protection of human health in indoor environments.