Sukjoon Oh

Dr. Sukjoon Oh

Korea Institute of Civil Engineering and Building Technology, Goyang-si, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Energy and Buildings
Verified
Journal Article
Closed access
Sukjoon OhSukjoon Oh
Sukjoon Oh
JHJeff S. Haberl
Jeff S. Haberl
JBJuan-Carlos Baltazar
Juan-Carlos Baltazar

27 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
Sukjoon OhSukjoon Oh
Sukjoon Oh
SSSuwon Song
Suwon Song
Thermal comfort, indoor air quality (IAQ), and energy use are closely related, even though these have different aspects with respect to building performance. We analyzed thermal comfort and IAQ using real-time multiple environmental data, which include indoor air temperature, relative humidity, carbon dioxide (CO2), and particulate matter (e.g., PM10 and PM2.5), as well as electricity use from an energy recovery ventilation (ERV) system for a childcare center. Thermal comfort frequency and time-series analyses were conducted in detail to thoroughly observe real-time thermal comfort and IAQ conditions with and without ERV operation, and to identify energy savings opportunities during occupied and unoccupied hours. The results show that the highest CO2 and PM10 concentrations were reduced by 51.4% and 29.5%, respectively, during the occupied hours when the ERV system was operating. However, it was also identified that comfort frequencies occurred during unoccupied hours and discomfort frequencies during occupied hours. By analyzing and communicating the three different types of real-time monitoring data, it is concluded that the ERV system should be controlled by considering not only IAQ (e.g., CO2 and PM2.5) but also thermal comfort and energy use to enhance indoor environmental quality and save energy based on real-time multiple monitoring data.

5 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
Sukjoon OhSukjoon Oh
Sukjoon Oh
SHSuyeon Ham
Suyeon Ham
Seongjin LeeSeongjin Lee
Seongjin Lee
This paper presents improved methods to detect cracks and thermal leakage in building envelopes using unmanned aerial vehicles (UAV) (i.e., drones) with video camcorders and/or infrared cameras. Three widely used contour detectors of Sobel, Laplacian, and Canny algorithms were compared to find a better solution with low computational overhead. Furthermore, a scheme using frame-based location identification was developed to effectively utilize the existing approach by finding the current location of the drone-assisted image frame. The results showed a simplified drone-assisted scheme along with automation, higher accuracy, and better speed while using lower battery energy. Furthermore, this paper found that the cost-effective drone with the attached equipment generated accurate results without using an expensive drone. The new scheme of this paper will contribute to automated anomaly detection, energy auditing, and commissioning for sustainably built environments.

14 September 2015 in Science and Technology for the Built Environment
Verified
Journal Article
Closed access
Sukjoon OhSukjoon Oh
Sukjoon Oh
JHJeff S. Haberl
Jeff S. Haberl
Many commercial buildings today do not perform the way they were simulated. One potential reason for this discrepancy is that designers using building energy simulation programs do not fully understand the analysis methods that the programs are based on and may therefore have unreasonable expectations about the actual system performance or energy use. Therefore, the purpose of this study is to trace the origins of the most widely used building energy simulation programs and the analysis methods of thermal envelope loads used in the software to analyze high-performance commercial buildings in the United States. Such an analysis is important to better understand the capabilities of building energy simulation programs so they can be used more accurately to simulate the performance of an intended design. In this study, a new comprehensive genealogy chart was developed to support the explanations for the origins of the analysis methods of thermal envelope loads used in whole-building energy simulation programs. Two other works (Oh and Haberl 2015a, 2015b) explained the origins of the analysis methods of solar photovoltaic, solar thermal, passive solar, and daylighting simulation programs.

28 December 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
Sukjoon OhSukjoon Oh
Sukjoon Oh
GCGyeong-Seok Choi
Gyeong-Seok Choi
HKHyoungsub Kim
Hyoungsub Kim
Pursuing innovations in sustainable architectural solutions, this study examines the impact of a climate-adaptive building envelope with dynamic photovoltaic integrated shading devices (PVSDs) on building performance. A major challenge in designing PVSDs is the lack of established guidelines for geometry and operations. We delve into the complexities and potential benefits of integrating dynamic PVSD designs into building performance simulations, particularly considering their time-varying geometric and operational aspects. This research assesses a range of similar PVSD design options with differing patterns, emphasizing their effects on solar energy potential, daylighting, and thermal efficiency. We conducted tests on south-oriented PVSDs (featuring two-axis rotation) in Houston, Texas, focusing on variables such as panel count (4 or 36), rotation angle range, and operational patterns (synchronized or individual). Regarding solar potential, the four-panel synchronized PVSD option outperformed static shading by 2.1 times. For daylighting and thermal performance, the 36-panel synchronized option with a wide rotation range and the four-panel individual option proved superior to other PVSD configurations, improving up to an average of 36% (sDA300/50%) and 1.5 °C, respectively. Our findings emphasize the critical role of integrating geometric design and operational patterns in PVSDs for enhanced system effectiveness and highlight PVSD design and application limitations. Our findings emphasize the critical role of integrating geometric design and operational patterns in PVSDs for enhanced system effectiveness. Furthermore, they shed light on the limitations in the PVSD design process and practical applications.

1 May 2020 in Energy and Buildings
Verified
Journal Article
Closed access
Sukjoon OhSukjoon Oh
Sukjoon Oh
KKKee Han Kim
Kee Han Kim