Dengwei Zhang

Prof. Dr. Dengwei Zhang

College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in APL Photonics
Verified
Journal Article
Open access
PDF file
Dengwei ZhangDengwei Zhang
Dengwei Zhang
Heming WeiHeming Wei
Heming Wei
HHHuizhu Hu
Huizhu Hu
SKSridhar Krishnaswamy
Sridhar Krishnaswamy
In this paper, a polymer micro-Fabry–Pérot interferometer (FPI) fabricated via direct laser writing using two-photon polymerization techniques on a single mode fiber tip is proposed, designed, simulated, and experimentally demonstrated as a magnetic field probe. The sensor comprises a tapered waveguide with a length of 100 µm and a diameter of 1 µm along the axis connecting the two reflecting surfaces of the micro-FPI open cavity. The cavity is filled with a magnetic fluid (MF) changing the evanescent coupling and consequently leading to a change in the phase of the FPI. To improve the signal reflection, a thin layer of Au is coated on the device before fabricating the probe sensor, which is then sealed in a MF-filled glass tube. The experimental results show that the proposed probe sensor has a low temperature sensitivity and a sensitivity to magnetic field as high as 1.54 nm/mT, and the magnetic field measurement accuracy is ∼649.4 μ T within a range from 1 mT to 8 mT. The microsensor, which is very stable and easy to fabricate, can be used as a probe to detect weak magnetic fields.

14 June 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LCLei Chen
Lei Chen
Dengwei ZhangDengwei Zhang
Dengwei Zhang
YZYilan Zhou
Yilan Zhou
CLCheng Liu
Cheng Liu
SCShuangliang Che
Shuangliang Che
A wide dynamic range, high precision, non-contact and large bandwidth angular displacement measurement (ADM) is greatly necessary for the applications such as industrial control and military equipment. This paper proposes a simple and effective ADM method based on Doppler Effect, heterodyne detection and diffuse reflection, which can fulfill these requirements simultaneously. Two beams of parallel light generated by a pair of laser Doppler vibrometers are incident upon the surface of rotational target, then data processing unit acquires the velocity of dual laser incident points on the moving target, and resolves the rotational angular displacement and translation displacement of target through the relationship between dual laser beams dynamically. Several major measurement errors that may affect the ADM accuracy are analyzed. A high precision rotary table is used as an angular displacement standard to verify the measurement range and accuracy, the verification experiment shows that the measurement range is not less than ±10° and the measurement accuracy is 0.0362° based on the method. After using a polynomial error compensation, the measurement accuracy can be promoted to 0.0088°, and this compensation method can be applied to real time measurement.

5 March 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Dengwei ZhangDengwei Zhang
Dengwei Zhang
YZYuxiang Zhao
Yuxiang Zhao
WFWenlan Fu
Wenlan Fu
WZWenqing Zhou
Wenqing Zhou
CLCheng Liu
Cheng Liu
SCShuangliang Che
Shuangliang Che
A theory for nonreciprocal phase shift caused by cross coupling generated in a polarization maintaining (PM) fiber optic gyroscope (FOG) under the combined action of magnetic and temperature fields is proposed. The magnetic-thermal coupling in the FOG originates from the interaction of the magnetic field, fiber twist, birefringence caused by thermal stress, and the intrinsic and bending birefringence of the fiber. The cross coupling changes with temperature. When the PM fiber has a diameter of 250 μm, beat length of 3 mm, length of 500 m, twist rate of 1  rad/m, and optical source wavelength of 1310 nm, the maximum degree of magnetic-thermal coupling generated by a 1 mT radial magnetic field within the temperature range of −20°C  to 60°C is −5.47%.

5 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Dengwei ZhangDengwei Zhang
Dengwei Zhang
CLCui Liang
Cui Liang
Nan LiNan Li
Nan Li
In this paper, a novel optical approach to double the sensitivity to angular rate of interferometric fiber optic gyroscope (IFOG) is proposed. Two fiber polarization combiner/splitters (FPCSs), as the key components, are added in the traditional IFOG light path. The FPCSs are able to either combine two orthogonal polarizations transmitting at two different polarization-maintaining fibers (PMFs) into the two orthogonal axes of one PMF, respectively, or split two polarizations transmitting at the two orthogonal axes of one PMF into two polarizations to transmit at two different PMFs, respectively. Through the specific placement and coupling of these two FPCSs, the incident light can transmit twice along the polarization-maintaining fiber coil (PMFC). The novel approach is verified experimentally and the experimental results show consistency with the theoretical analysis. The proposed approach is able to double the sensitivity of IFOGs and can increase the signal-to-noise ratio (SNR) without increasing the length of PMFC, which is very susceptible to environmental influences and is of great significance in the technical improvement of IFOGs, as well as the miniaturization of IFOGs.

23 April 2019 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
CLCui Liang
Cui Liang
Dengwei ZhangDengwei Zhang
Dengwei Zhang
YZYilan Zhou
Yilan Zhou
XSXiaowu Shu
Xiaowu Shu
SCShuangliang Che
Shuangliang Che
CLCheng Liu
Cheng Liu
A coupling effect in the single-mode fiber coil (SMFC) of a depolarized interference fiber optic gyroscope (De-IFOG) under time-varying temperature and magnetic field, which can cause a serious nonreciprocal phase error, is revealed. In this paper, the mechanism of the coupling effect is thoroughly studied and the related theory is derived in detail. Simulations and experiments are carried out to verify the validity. The experiments show a peak-to-peak value error of about 50 °/h in the SMFC when the magnitude of magnetic field is 10 Gauss and the temperature uniformly increases from 10 to 60 °C at the rate of 36 °C/h, which cannot be neglected in the applications of De-IFOGs.

17 January 2023 in Photonics
Verified
Journal Article
Open access
PDF file
CLCui Liang
Cui Liang
ZZZhihang Zhang
Zhihang Zhang
Dengwei ZhangDengwei Zhang
Dengwei Zhang
THTengchao Huang
Tengchao Huang
SCShuangliang Che
Shuangliang Che
A novel fiber-optic magnetic field sensor, based on a Sagnac structure, is proposed with the approach of polarization interference detection. The sensor takes advantage of common path interference, combining with a high magnetic field sensitivity sensing unit, composed of magneto-optical crystal, and magnetic field concentrators, to achieve high resolution, high stability, and large dynamic measurement of DC magnetic field signals. In this paper, the theoretical model is established and the related theory is derived in detail. The key technologies in the system are thoroughly investigated and verified. Experimental research on the proposed system is demonstrated and the results show that a DC magnetic field resolution of 5.6 nT and a dynamic range of larger than 70 dB is achieved. Furthermore, the linearity of the system is greater than 99.8% and the instability is less than 0.5%.