Maxwell Hein

Mr. Maxwell Hein

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
MHMaxwell Hein
Maxwell Hein
NDNelson Filipe Lopes Dias
Nelson Filipe Lopes Dias
SPSudipta Pramanik
Sudipta Pramanik
DSDominic Stangier
Dominic Stangier
Kay-Peter HoyerKay-Peter Hoyer
Kay-Peter Hoyer
MSMirko Schaper
Mirko Schaper
Titanium alloys, especially β alloys, are favorable as implant materials due to their promising combination of low Young’s modulus, high strength, corrosion resistance, and biocompatibility. In particular, the low Young’s moduli reduce the risk of stress shielding and implant loosening. The processing of Ti-24Nb-4Zr-8Sn through laser powder bed fusion is presented. The specimens were heat-treated, and the microstructure was investigated using X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. The mechanical properties were determined by hardness and tensile tests. The microstructures reveal a mainly β microstructure with α″ formation for high cooling rates and α precipitates after moderate cooling rates or aging. The as-built and α″ phase containing conditions exhibit a hardness around 225 HV5, yield strengths (YS) from 340 to 490 MPa, ultimate tensile strengths (UTS) around 706 MPa, fracture elongations around 20%, and Young’s moduli about 50 GPa. The α precipitates containing conditions reveal a hardness around 297 HV5, YS around 812 MPa, UTS from 871 to 931 MPa, fracture elongations around 12%, and Young’s moduli about 75 GPa. Ti-24Nb-4Zr-8Sn exhibits, depending on the heat treatment, promising properties regarding the material behavior and the opportunity to tailor the mechanical performance as a low modulus, high strength implant material.

8 January 2022 in Metals
Verified
Journal Article
Open access
PDF file
MHMaxwell Hein
Maxwell Hein
DKDavid Kokalj
David Kokalj
NDNelson Filipe Lopes Dias
Nelson Filipe Lopes Dias
DSDominic Stangier
Dominic Stangier
HOHilke Oltmanns
Hilke Oltmanns
MSMirko Schaper
Mirko Schaper
In biomedical engineering, laser powder bed fusion is an advanced manufacturing technology, which enables, for example, the production of patient-customized implants with complex geometries. Ti-6Al-7Nb shows promising improvements, especially regarding biocompatibility, compared with other titanium alloys. The biocompatible features are investigated employing cytocompatibility and antibacterial examinations on Al2O3-blasted and untreated surfaces. The mechanical properties of additively manufactured Ti-6Al-7Nb are evaluated in as-built and heat-treated conditions. Recrystallization annealing (925 °C for 4 h), β annealing (1050 °C for 2 h), as well as stress relieving (600 °C for 4 h) are applied. For microstructural investigation, scanning and transmission electron microscopy are performed. The different microstructures and the mechanical properties are compared. Mechanical behavior is determined based on quasi-static tensile tests and strain-controlled low cycle fatigue tests with total strain amplitudes εA of 0.35%, 0.5%, and 0.8%. The as-built and stress-relieved conditions meet the mechanical demands for the tensile properties of the international standard ISO 5832-11. Based on the Coffin–Manson–Basquin relation, fatigue strength and ductility coefficients, as well as exponents, are determined to examine fatigue life for the different conditions. The stress-relieved condition exhibits, overall, the best properties regarding monotonic tensile and cyclic fatigue behavior.

16 July 2021 in Materialwissenschaft und Werkstofftechnik
Verified
Journal Article
Open access
PDF file
MHMaxwell Hein
Maxwell Hein
KHK.‐P. Hoyer
K.‐P. Hoyer
MSM. Schaper
M. Schaper
Laser beam melting (LBM) is an advanced manufacturing technology providing special features and the possibility to produce complex and individual parts directly from a CAD model. TiAl6V4 is the most common used titanium alloy particularly in biomedical applications. TiAl6Nb7 shows promising improvements especially regarding biocompatible properties due to the substitution of the hazardous vanadium. This work focuses on the examination of laser beam melted TiAl6Nb7. For microstructural investigation scanning electron microscopy including energy‐dispersive x‐ray spectroscopy as well as electron backscatter diffraction are utilized. The laser beam melted related acicular microstructure as well as the corresponding mechanical properties, which are determined by hardness measurements and tensile tests, are investigated. The laser beam melted alloy meets, except of breaking elongation A, the mechanical demands like ultimate tensile strength Rm, yield strength Rp0.2, Vickers hardness HV of international standard ISO 5832‐11. Next steps contain comparison between TiAl6Nb7 and TiAl6V4 in different conditions. Further investigations aim at improving mechanical properties of TiAl6Nb7 by heat treatments and assessment of their influence on the microstructure as well as examination regarding the corrosive behavior in human body‐like conditions.

17 November 2023 in Crystals
Verified
Journal Article
Open access
PDF file
SPSudipta Pramanik
Sudipta Pramanik
DMDennis Milaege
Dennis Milaege
MHMaxwell Hein
Maxwell Hein
Kay-Peter HoyerKay-Peter Hoyer
Kay-Peter Hoyer
MSMirko Schaper
Mirko Schaper
The effect of plaque deposition (atherosclerosis) on blood flow behaviour is investigated via computational fluid dynamics and structural mechanics simulations. To mitigate the narrowing of coronary artery atherosclerosis (stenosis), the computational modelling of auxetic and non-auxetic stents was performed in this study to minimise or even avoid these deposition agents in the future. Computational modelling was performed in unrestricted (open) conditions and restricted (in an artery) conditions. Finally, stent designs were produced by additive manufacturing, and mechanical testing of the stents was undertaken. Auxetic stent 1 and auxetic stent 2 exhibit very little foreshortening and radial recoil in unrestricted deployment conditions compared to non-auxetic stent 3. However, stent 2 shows structural instability (strut failure) during unrestricted deployment conditions. For the restricted deployment condition, stent 1 shows a higher radial recoil compared to stent 3. In the tensile test simulations, short elongation for stent 1 due to strut failure is demonstrated, whereas no structural instability is noticed for stent 2 and stent 3 until 0.5 (mm/mm) strain. The as-built samples show a significant thickening of the struts of the stents resulting in short elongations during tensile testing compared to the simulations (stent 2 and stent 3). A modelling framework for the stent deployment system that enables the selection of appropriate stent designs before in vivo testing is required. This leads to the acceleration of the development process and a reduction in time, resulting in less material wastage. The modelling framework shall be useful for doctors designing patient-specific stents.

24 August 2022 in Crystals
Verified
Journal Article
Open access
PDF file
MHMaxwell Hein
Maxwell Hein
Load-bearing permanent implants, such as hip or knee joint replacements, are permanently loaded in the human body and must withstand considerable high loading cycles. The characteristic properties of additively manufactured Ti-6Al-7Nb, manufactured by laser powder bed fusion (LPBF), such as a rough surface and high residual stresses, have a detrimental effect on the fatigue behavior of such components. Functional physical vapor deposition (PVD) coatings and heat treatments offer the possibility to influence these properties. For this reason, the effects of stress-relief heat treatment (SR; 600 °C/4 h) and three PVD coatings (titanium nitride (TiN), titanium carbonitride (TiCN), and silver-containing amorphous carbon (a-C:Ag)) on the mechanical properties, in terms of high-cycle fatigue, are identified. Wöhler curves are determined and the staircase procedure ascertains the fatigue strengths. The fatigue strengths increase compared to the as-built condition by 105.4% (SR), 44.2% (TiN), 31.1% (TiCN), and 2.6% (a-C:Ag). Fracture surfaces are analyzed by scanning electron microscopy and show LPBF characteristic defects such as pores. The surfaces are partially divided into forced and fatigue fracture, the latter characterized by fatigue striations. Overall, PVD coatings, and especially SR, lead to an improved high-cycle fatigue behavior.