Monika Wiśnik-Sawka

Dr. Monika Wiśnik-Sawka

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
MMMirosław Maziejuk
Mirosław Maziejuk
MSMonika Szyposzyńska
Monika Szyposzyńska
ASAleksandra Spławska
Aleksandra Spławska
MWMonika Wiśnik-Sawka
Monika Wiśnik-Sawka
MCMichał Ceremuga
Michał Ceremuga
One of the significant problems in the modern world is the detection of improvised explosives made of materials synthesized at home. Such compounds include triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD). An attempt was made to construct an instrument allowing for the simultaneous detection of both compounds despite the large difference of vapor pressure: very high for TATP and very low for HMTD. The developed system uses differential ion mobility spectrometry (DMS) in combination with a specially designed gas sample injection system. The created system of detectors allowed for the detection of a high concentration of TATP and a very low concentration of HMTD. TATP detection was possible despite the presence of impurities—acetone remaining from the technological process and formed as a coproduct of diacetone diperoxide (DADP) synthesis. Ammonia added to the carrier gas improved the possibility of detecting the abovementioned explosives, reducing the intensity of the acetone signal. The obtained results were then compared with the detection capabilities of drift tube ion mobility spectrometer (DT-IMS), which has not made possible such detection as DMS.

30 December 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Wojciech FabianowskiWojciech Fabianowski
Wojciech Fabianowski
MMMirosław Maziejuk
Mirosław Maziejuk
MSMonika Szyposzyńska
Monika Szyposzyńska
MWMonika Wiśnik-Sawka
Monika Wiśnik-Sawka
The article presents a technique of differential ion mobility spectrometry (DMS) applicable to the detection and identification of volatile organic compounds (VOCs) from such categories as n-alkanes, alcohols, acetate esters, ketones, botulinum toxin, BTX, and fluoro- and chloro-organic compounds. A possibility of mixture identification using only the DMS spectrometer is analyzed, and several examples are published for the first time. An analysis of different compounds and their mechanisms of fragmentation, influence on effective ion temperature, and high electric field intensity is discussed.

1 March 2019 in Talanta
Verified
Journal Article
Closed access
EBEdyta Budzyńska
Edyta Budzyńska
MGMichał Grabka
Michał Grabka
JKJanina Kopyra
Janina Kopyra
MMMirosław Maziejuk
Mirosław Maziejuk
ZSZahra Safaei
Zahra Safaei
Jaroslaw PutonJaroslaw Puton
Jaroslaw Puton

8 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
AKAngelika Monika Kołacz
Angelika Monika Kołacz
MWMonika Wiśnik-Sawka
Monika Wiśnik-Sawka
MMMirosław Maziejuk
Mirosław Maziejuk
MNMarek Natora
Marek Natora
WHWładyslaw Harmata
Władyslaw Harmata
DGDorota Gajda
Dorota Gajda
It has become increasingly important to monitor environment contamination by such chemicals as chemical warfare agents (CWAs) and industrial toxic chemicals (TICs), as well as radiation hazards around and inside collective protection facilities. This is especially important given the increased risk of terrorist or military attacks. The Military Institute of Chemistry and Radiometry (MICR) has constructed and developed the ALERT device for the effective monitoring of these threats. This device uses sensors that detect chemical and radiological contaminations in the air. The CWA detector is an ion mobility spectrometer, TICs are detected by electrochemical sensors, and radiation hazards are detected via Geiger–Muller tubes. The system was designed to protect the crew from contamination. When chemical or radioactive contamination is detected at the air inlet for the shelter, air filtration through a carbon filter is activated. At this time, the air test procedure at the filter outlet is started to test the condition of the filter on an ongoing basis. After detecting contamination at the filter outlet, the system turns off the air pumping and the service can start the procedure of replacing the damaged carbon filter. This paper presents the results of laboratory testing of the ALERT gas alarm detector, which showed high measurements for important parameters, including sensitivity, repeatability, accuracy, and speed.

24 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
KMKarolina Morawska
Karolina Morawska
TSTomasz Sikora
Tomasz Sikora
ANAleksandra Nakonieczna
Aleksandra Nakonieczna
RTRenata Tyśkiewicz
Renata Tyśkiewicz
MWMonika Wiśnik-Sawka
Monika Wiśnik-Sawka
ZWZygfryd Witkiewicz
Zygfryd Witkiewicz
The Centers for Disease Control and Prevention (CDC) classifies Bacillus anthracis as one of the most dangerous pathogens that may affect public health and national security. Due to its importance as a potential biological weapon, this bacteria has been classified in the highest category A, together with such pathogens as variola virus or botulinum neurotoxin. Characteristic features of this pathogen that increase its military importance are the ease of its cultivation, transport, and storage and its ability to create survival forms that are extremely resistant to environmental conditions. However, beyond bioterrorism, B. anthracis is also a naturally occurring pathogen. Anthrax outbreaks occur in livestock and wildlife, particularly in spore-contaminated regions of Africa, Asia, and North America. Spores persist for decades, leading to recurrent infections and zoonotic transmission through direct contact, inhalation, or consumption of contaminated meat. This work presents a new electrochemical method for detecting and quantifying B. anthracis in spore form using a selective immune reaction. The developed method is based on the thiol-modified electrodes that constitute the sensing element of the electrochemical system. Tests with the B. anthracis spore suspension showed that the detection limit for this pathogen is as low as 103 CFU/mL. Furthermore, it was possible to quantify the analyte with a sensitivity of 11 mV/log (CFU/mL). Due to several features, such as low unit cost, portability, and minimal apparatus demands, this method can be easily implemented in field analyzers for this pathogen and provides an alternative to currently used techniques and devices.

29 June 2020 in Molecules
Verified
Journal Article
Open access
PDF file
MWMonika Wiśnik-Sawka
Monika Wiśnik-Sawka
EBEdyta Budzyńska
Edyta Budzyńska
Jaroslaw PutonJaroslaw Puton
Jaroslaw Puton
Drift tube ion mobility spectrometers (DT IMS) allow the concentration of different organic compounds to be measured. This gives the opportunity to use these detectors in measuring the penetration of various substances through polymer membranes. Permeation measurements of two substances (2-heptanone and dimethyl methylphosphonate (DMMP)) through a cylindrical silicone rubber membrane were carried out. The membrane separated the aqueous solution from the air. The analyte was introduced into water, and then its concentration in air on the opposite side of the membrane was recorded. Based on the dynamics of detector signal changes, the diffusion coefficients for both tested substances were determined. Determination of permeability coefficients was based on precise quantitative measurements, which took into account the non-linearity of the detector characteristics and the effect of water on detection sensitivity. The analysis of measurement results was based on a mathematical description of diffusion process.