Terry Lowe

Prof. Terry Lowe


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2021 in MRS Bulletin
Verified
Journal Article
Closed access
PDF file
TLTerry Lowe
Terry Lowe
Ruslan ValievRuslan Valiev
Ruslan Valiev
Xiaochun LiXiaochun Li
Xiaochun Li
BEBenjamin R. Ewing
Benjamin R. Ewing

15 January 2006 in Materials Science Forum
Verified
Journal Article
Closed access
PDF file
VLV.V. Latysh
V.V. Latysh
Irina SemenovaIrina Semenova
Irina Semenova
GSG.H. Salimgareeva
G.H. Salimgareeva
IKI.V. Kandarov
I.V. Kandarov
YZYuntian Zhu
Yuntian Zhu
Ruslan ValievRuslan Valiev
Ruslan Valiev
This paper studies the effect of combined SPD treatment on microstructure and mechanical properties of semi-products out of CP Ti. The combined processing, consisting of equal-channel angular pressing and further thermomechanical treatment, produced ultrafine-grained rods out of Grade 2 CP Ti with a diameter of 6.5 mm and a length of up to 1 m. It was established that the formation of homogeneous ultrafine-grained structure in Ti rod with α-grain size of about 100 nm allowed to enhance yield stress by 200% in comparison with initial annealed state.

7 April 2020 in Materials Research Letters
Verified
Journal Article
Open access
TLTerry Lowe
Terry Lowe
RRRebecca A. Reiss
Rebecca A. Reiss
PIPatrick E. Illescas
Patrick E. Illescas
CDCasey F. Davis
Casey F. Davis
MCMelanie C. Connick
Melanie C. Connick
JSJohnny A. Sena
Johnny A. Sena
Studies since 2004 have shown that the cytocompatibility of ultrafine grain (UG) commercial purity (CP) titanium exceeds that of coarse grain (CG) CP titanium (Ti) by 30% to 20-fold. To isolate the factors affecting this large reported variability of CP titanium’s cytocompatibility, discs of UG and CG titanium were fabricated with controlled texture and roughness. The discs were seeded with MC3T3-E1 pre-osteoblastic cells and cultured for 72 h. The proliferation of cells on polished UG-Ti exceeded unpolished CG-Ti 3.04-fold. Cell proliferation was found to correlate with a new biophysical parameter, the average grain boundary length per surface-attached cell. GRAPHICAL ABSTRACT IMPACT STATEMENT By eliminating the influences of texture and roughness we have isolated the positive correlation between MC3TE-E1 cell proliferation on titanium and grain boundary length per surface-attached cell.

4 July 2014
Verified
Book Chapter
Closed access
PDF file
TLTerry Lowe
Terry Lowe
RVR.Z. Valiev
R.Z. Valiev

21 May 2020 in JOM
Verified
Journal Article
Closed access
PDF file
CDCasey F. Davis
Casey F. Davis
AGAdam J. Griebel
Adam J. Griebel
TLTerry Lowe
Terry Lowe

9 September 2024 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
SAShahram Amini
Shahram Amini
HCHongbin Choi
Hongbin Choi
WSWesley Seche
Wesley Seche
ABAlexander Blagojevic
Alexander Blagojevic
NMNicholas May
Nicholas May
SSSina Shahbazmohamadi
Sina Shahbazmohamadi
Over the last two decades, platinum group metals (PGMs) and their alloys have dominated as the materials of choice for electrodes in long-term implantable neurostimulation and cardiac rhythm management devices due to their superior conductivity, mechanical and chemical stability, biocompatibility, corrosion resistance, radiopacity, and electrochemical performance. Despite these benefits, PGM manufacturing processes are extremely costly, complex, and challenging with potential health hazards. Additionally, the volatility in PGM prices and their high supply risk, combined with their scarce concentration of approximately 0.01 ppm in the earth’s upper crust and limited mining geographical areas, underscores their classification as critical raw materials, thus, their effective recovery or substitution worldwide is of paramount importance. Since postmortem recovery from deceased patients and/or refining of PGMs that are used in the manufacturing of the electrodes and microelectrode arrays is extremely rare, challenging, and highly costly, therefore, substitution of PGM-based electrodes with other biocompatible materials that can yield electrochemical performance values equal or greater than PGMs is the only viable and sustainable solution to reduce and ultimately substitute the use of PGMs in long-term implantable neurostimulation and cardiac rhythm management devices. In this article, we demonstrate for the first time how the novel technique of “reactive hierarchical surface restructuring” can be utilized on titanium—that is widely used in many non-stimulation medical device and implant applications—to manufacture biocompatible, low-cost, sustainable, and high-performing neurostimulation and cardiac rhythm management electrodes. We have shown how the surface of titanium electrodes with extremely poor electrochemical performance undergoes compositional and topographical transformations that result in electrodes with outstanding electrochemical performance.