The tortuosity changes of curvilinear anatomical organs such as nerve fibers or vessels have a close relationship with a number of diseases. Therefore, the automatic estimation and representation of the tortuosity is desired in medical image for such organs. In this paper, an automated framework for tortuosity estimation is proposed for corneal nerve and retinal vessel images. First, the weighted local phase tensor-based enhancement method is employed and the curvilinear structure is extracted from raw image. For each curvilinear structure with a different position and orientation, the curvature is measured by the exponential curvature estimation in the 3D space. Then, the tortuosity of an image is calculated as the weighted average of all the curvilinear structures. Our proposed framework has been evaluated on two corneal nerve fiber datasets and one retinal vessel dataset. Experiments on three curvilinear organ datasets demonstrate that our proposed tortuosity estimation method achieves a promising performance compared with other state-of-the-art methods in terms of accuracy and generality. In our nerve fiber dataset, the method achieved overall accuray of 0.820, and 0.734, 0.881 for sensitivity and specificity, respectively. The proposed method also achieved Spearman correlation scores 0.945 and 0.868 correlated with tortuosity grading ground truth for arteries and veins in the retinal vessel dataset. Furthermore, the manual labeled 403 corneal nerve fiber images with different levels of tortuosity, and all of them are also released for public access for further research.
Purpose: To assess whether a generative adversarial network (GAN) could synthesize realistic optical coherence tomography (OCT) images that satisfactorily serve as the educational images for retinal specialists and the training datasets for the classification of various retinal disorders using deep learning (DL). Methods: The GANs architecture was adopted to synthesis high-resolution OCT images training on a publicly available OCT dataset including urgent referrals (choroidal neovascularization and diabetic macular edema) and non-urgent referrals (normal and drusen). 400 real and synthetic OCT images were evaluated by 2 retinal specialists to assess image quality. We further trained 2 DL models on either real or synthetic datasets and compared the performance of urgent vs nonurgent referrals diagnosis tested on a local (1000 images from the public dataset) and clinical validation dataset (278 images from Shanghai Shibei Hospital). Results: The image quality of real vs synthetic OCT images was similar as assessed by 2 retinal specialists. The accuracy of discrimination as real vs synthetic OCT images was 59.50% for retinal specialist 1 and 53.67% for retinal specialist 2. For the local dataset, the DL model trained on real (DL_Model_R) and synthetic OCT images (DL_Model_S) had an area under the curve (AUC) of 0.99, and 0.98 respectively. For the clinical dataset, the AUC was 0.94 for DL_Model_R, 0.90 for DL_Model_S. Conclusions: The GAN-synthetic OCT images can be used by clinicians for educational purposes and developing DL algorithms. Translational Relevance: The medical image synthesis based on GANs is promising in human and machine to fulfill clinical tasks.