Joseph Sanderson

Prof. Dr. Joseph Sanderson

Department of Physics and Astronomy, University of Waterloo, Waterloo, ON, Canada

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2021 in Chemistry of Materials
Verified
Journal Article
Closed access
FYFan Ye
Fan Ye
DCDarren Chang
Darren Chang
AAAhsan Aamir Ayub
Ahsan Aamir Ayub
KIKhaled Ibrahim
Khaled Ibrahim
ASAhmed Shahin
Ahmed Shahin
KMKevin P. Musselman
Kevin P. Musselman

18 October 2016 in Journal of Physics B: Atomic, Molecular and Optical Physics
Verified
Journal Article
Closed access
PDF file
ARAli Ramadhan
Ali Ramadhan
BWBenji Wales
Benji Wales
RKReza Karimi
Reza Karimi
IGIsabelle Gauthier
Isabelle Gauthier
MMMichael MacDonald
Michael MacDonald
JSJoseph Sanderson
Joseph Sanderson
Soft x-rays (90–173 eV) from the 3rd generation Canadian Light Source have been used in conjunction with a multi coincidence time and position sensitive detection apparatus to observe the dissociative ionization of OCS. By varying the x-ray energy we can compare dynamics from direct and Auger ionization processes, and access ionization channels which result in two or three body breakup, from 2+ to 4+ ionization states. We make several new observations for the 3+ state such as kinetic energy release limited by photon energy, and using Dalitz plots we can see evidence of timescale effects between the direct and Auger ionization process for the first time. Finally, using Dalitz plots for OCS 4+ we observe for the first time that breakup involving an O 2+ ion can only proceed from out of equilibrium nuclear arrangement for S(2p) Auger ionization.

8 November 2021 in OSA Continuum
Verified
Journal Article
Open access
AVArmaghan Vahidnia
Armaghan Vahidnia
KMKhosro Madanipour
Khosro Madanipour
RARobabeh Abedini
Robabeh Abedini
RKReza Karimi
Reza Karimi
JSJoseph Sanderson
Joseph Sanderson
Parvin ParvizParvin Parviz
Parvin Parviz
A simple and effective polarimetric technique is used to discriminate benign lesions from cancerous ones. This method is based on key polarimetric parameters of diattenuation, depolarization, and retardance. Several samples of human skin exhibiting three kinds of cancer as well as benign specimens are examined using a polarimetric technique and results are compared with pathology diagnosis. In this study polarimetric parameters are taken into account as a reliable diagnostic tool to distinguish the cancerous lesions precisely and non-invasively.

19 December 2024 in Communications Physics
Verified
Journal Article
Open access
PDF file
AAAydin Ashrafi-Belgabad
Aydin Ashrafi-Belgabad
RKReza Karimi
Reza Karimi
MMMohammad Monfared
Mohammad Monfared
KTKaili Tian
Kaili Tian
PPParviz Parvin
Parviz Parvin
JSJoseph Sanderson
Joseph Sanderson
Coulomb explosion is an established momentum imaging technique, where the molecules are ionized multiple times on a femtosecond time scale before breaking up into ionized fragments. By measuring the momentum of all the ions, information about the initial molecular structure is theoretically available. However, significant geometric changes due to multiple ionizations occur before the explosion, posing a challenge in retrieving the ground-state structure of molecules from the measured momentum values of the fragments. In this work, we investigate theoretically and experimentally such a connection between the ground-state geometry of a polyatomic molecule (OCS) and the detected momenta of ionic fragments from the Coulomb explosion. By relying on time-dependent density functional theory (TDDFT), we can rigorously model the ionization dynamics of the molecule in the tunneling regime. We reproduce the energy release and the Newton plot momentum patterns of an experiment in which OCS is ionized to the 6+ charge state. Our results provide insight into the behavior of molecules during strong field multiple ionization, opening a way toward precision imaging of real-space molecular geometries using tabletop lasers.

24 July 2024 in Materials
Verified
Journal Article
Open access
PDF file
LZLiena Zaidan
Liena Zaidan
INInna Novodchuk
Inna Novodchuk
AHAlexander H.Xu
Alexander H.Xu
ANAlexandru Nica
Alexandru Nica
Saeed TakalooSaeed Takaloo
Saeed Takaloo
Mustafa YavuzMustafa Yavuz
Mustafa Yavuz
Escherichia coli (E. coli) was among the first organisms to have its complete genome published (Genome Sequence of E. coli 1997 Science). It is used as a model system in microbiology research. E. coli can cause life-threatening illnesses, particularly in children and the elderly. Possible contamination by the bacteria also results in product recalls, which, alongside the potential danger posed to individuals, can have significant financial consequences. We report the detection of live Escherichia coli (E. coli) in liquid samples using a biosensor based on a field-effect transistor (FET) biosensor with B/N co-coped reduced graphene oxide (rGO) gel (BN-rGO) as the transducer material. The FET was functionalized with antibodies to detect E. coli K12 O-antigens in phosphate-buffered saline (PBS). The biosensor detected the presence of planktonic E. coli bacterial cells within a mere 2 min. The biosensor exhibited a limit of detection (LOD) of 10 cells per sample, which can be extrapolated to a limit of detection at the level of a single cell per sample and a detection range of at least 10–108 CFU/mL. The selectivity of the biosensor for E. coli was demonstrated using Bacillus thuringiensis (B. thuringiensis) as a sample contaminant. We also present a comparison of our functionalized BN-rGO FET biosensor with established detection methods of E. coli k12 bacteria, as well as with state-of-the-art detection mechanisms.

8 September 2015 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
ARAli Ramadhan
Ali Ramadhan
MWMichal Wesolowski
Michal Wesolowski
TWTomonari Wakabayashi
Tomonari Wakabayashi
HSHaruo Shiromaru
Haruo Shiromaru
TFTatsuya Fujino
Tatsuya Fujino
JSJoseph Sanderson
Joseph Sanderson
Hydrogen-capped and methyl-capped carbon chains (polyynes) have been generated by intense femtosecond laser irradiation of pure liquid toluene. UV-Vis and Raman spectroscopy were used to confirm the presence of polyynes in the irradiated samples, and high performance liquid chromatography (HPLC) was used to separate polyynes up to C18 H2 and HC13 CH3.