Urban areas are characterized by a plurality of microclimates given by the diversity of morphologies, optical and radiative properties, solar access and air circulation in different street canyons. For these reasons, beyond strategies at urban scale, mitigation needs to be addressed at district or even at urban canyon scale, just like the design of buildings. Among different options, canopy shading has been proposed in several urban contexts, and to assess the impact of this mitigation technique on air temperature and outdoor thermal comfort conditions we performed numerical simulations for a north-south oriented urban canyon with high solar access (height to width ratio equal to 0.18) in the climate context of Milano (Italy)
This paper presents an approach to measure, characterize and simulate photometric performances of light transmission efficiency of an innovative transparent concrete panel for façades. The transparency was obtained by a texture of PMMA resin insertions in the fiber reinforced concrete panel. In the first part of the paper integrating sphere measurements were collected to derive spectral optical properties of the panel. The optical properties of a specimen were measured for incidence angles between normal and 60° and the spectral results were reported. The data collected during the measures were used to: create and validate a simplified Radiance model of the panel and to optimize simulation parameters to estimate properly the total internal reflections effects thought the PMMA resin insertions
This paper is divided in two sections. The first section present the measurement and evaluation of soiling effects of spectral light and solar transmittance decay of Ethylene Tetrafluoroethylene Copolymer (ETFE) membranes after three and six months of exposure in Milano city outdoor urban conditions, with different tilt and orientation. The obtained values where use to compute thermal and solar properties of a multilayer ETFE panel.The second section presents the results of an experimental campaign for measuring thermal transmittance of a non-pneumatic and non-cushion shape double layer ETFE sample panel realized with two membranes parallel to each other and tensioned on a frame. The thermal transmittance measurement reflects ISO 9869 measurement approach combined with the use of a thermographic camera to evaluate surface temperatures over the sample panel
This paper presents the results of the analysis conducted on six case studies related to solar energy integration in urban and rural environments located on the Italian territory. The analysis has been carried out within the Subtask C—Case Studies and Action Research of the International Energy Agency Solar Heating and Cooling Program Task 51 “Solar Energy in Urban Planning”. Three different environments hosting active and passive solar energy systems (existing urban areas, new urban areas, and agricultural/rural areas) have been investigated to attain lessons learned and recommendations. Findings suggest that (a) it is important to consider solar energy from the early stages of the design process onwards to achieve satisfactory levels of integration; (b) a higher level of awareness regarding solar potential at the beginning of a project permits acting on its morphology, achieving the best solution in terms of active and passive solar gains; (c) when properly designed, photovoltaic systems can act as characterizing elements and as a distinctive architectural material that is able to valorize the aesthetic of the entire urban intervention; (d) further significant outcomes include the importance of supporting the decision strategies with quantitative and qualitative analyses, the institution of coordinating bodies to facilitate the discussion between stakeholders, and the need for deep renovation projects to fully impact existing buildings’ stock; (e) when large solar installations are planned at the ground level, a landscape design approach should be chosen, while the ecological impact should be reduced by carefully planning the adoption of alternative solutions (e.g., agrivoltaics) compatible with the existing land use.
Urban climates are highly influenced by the ability of built surfaces to reflect solar radiation, and the use of high-albedo materials has been widely investigated as an effective option to mitigate urban overheating. While diffusely solar reflective walls have attracted concerns in the architectural and thermal comfort community, the potential of concave and polished surfaces, such as glass and metal panels, to cause extreme glare and localized thermal stress has been underinvestigated. Furthermore, there is the need for a systematic comparison of the solar concentration at the pedestrian level in front of tall buildings. Herein, we show the findings of an experimental campaign measuring the magnitude of the sunlight reflected by scale models reproducing archetypical tall buildings. Three 1:100 scaled prototypes with different shapes (classic vertical façade, 10% tilted façade, curved concave façade) and different finishing materials (representative of extremes in reflectance properties of building materials) were assessed. A specular surface was assumed as representative of a glazed façade under high-incidence solar angles, while selected light-diffusing materials were considered sufficient proxies for plaster finishing. With a diffusely reflective façade, the incident radiation at the pedestrian level in front of the building did not increase by more than 30% for any geometry. However, with a specular reflective (i.e., mirror-like) flat façade, the incident radiation at the pedestrian level increased by more than 100% and even by more than 300% with curved solar-concentrating geometries. In addition, a tool for the preliminary evaluation of the solar reflectance risk potential of a generic complex building shape is developed and presented. Our findings demonstrate that the solar concentration risk due to mirror-like surfaces in the built environment should be a primary concern in design and urban microclimatology.