The rapidly increasing distributed energy resources (DERs) in power systems are now getting interconnected to set community grid structures, where power quality will be a major concern. The grid-to-grid (G2G) bidirectional power transfer among the distribution microgrid will not be considered commercially feasible unless the upstream harmonics are under the limits. The aggregation of such harmonics, measured as total harmonic distortion (THD), is feared to be beyond tolerable limits with the progression of rooftop grid-tied PV-like installations. Hence, this THD needs to be characterized with DER generation end variables. In this work, the photovoltaic (PV) DERs’ dependency on environment variables such as irradiance was profiled in the context of generating and injecting harmonics into the grid. A mathematical model of a grid-tied three-phase PV DER was developed as part of this correlation characterization, matching the fundamental unit structure of a 1.4 MW solar canopy located on the Florida International University (FIU) Miami campus. To determine the qualitative association with produced THD patterns, the model was evaluated with various irradiance settings. A real-time digital simulation (RTDS) platform was used to verify it. Following this confirmation, sets of data from power quality meters at the point of common coupling and FIU field sensors were utilized to validate further the correlation model. The results showed that the grid current’s THD exhibited a high correlation with the irradiance profile and its variation over time. The early morning and late afternoon periods of the day, associated with a low irradiance, constantly had higher harmonics generated from the PV DER. The midday THD was rather rational with partial shadings, hence a geolocation-dependent factor. These findings were verified by an RTDS and validated by real field data. In quantifying the THD injected by a single DER at a high-frequency (2–150 kHz) supraharmonics (SH) level, a 3% peak increment in magnitude was observed from the high-fixed to the low-fixed irradiance profile. The correlation characteristics depicted that the hybrid microgrid suffered from a daytime-dependent harmonic insertion from the grid-tied DER. This is a global problem unless specific measures are taken to mitigate the harmonics. The electrically notorious higher-frequency SH was found to increase proportionally. The G2G power transfer can be limited because of the higher THD in the early morning and late afternoon, which will also worsen because the numbers of grid-tied PV DERs (i.e., rooftop solar and industrial solar) are likely to increase rapidly soon. The community grid structure can thus have a controlled harmonics filtration setup purposefully designed to address the findings of this work, which also fall within the scope of our future research.
13 November 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In commercial applications, the operation of DC/DC converters significantly impacts overall system performance and long-term reliability. This study introduces a data-driven digital twin ( DT ) approach for estimating critical degradation parameters of DC/DC BUCK converter under steady-state condition. Initially, a circuit-level MATLAB/Simulink digital model ( DMC ) is refined against a hardware prototype’s switching model dataset using offline particle swarm optimization. The optimized digital model’s steady-state response is then verified with its average model response while varying the duty and load. Subsequently, degradation profiles are imposed on the inductor, capacitor, MOSFET in the DMC . A large dataset is generated from this model, allowing training, validation, and testing of machine learning (ML) models for component health regression tasks. The proposed method employs random forest ML models, achieving impressive regression results with a squared R value as high as 0.99978 and a root mean square error of 4.2× 10 −6 . The method is further validated on a medium power level DC/DC BUCK prototype with varying load conditions, and includes the analysis of MOSFET’s on-resistance under degradation conditions. This data-driven DT method shows promise for identifying parasitic degradation and ohmic loss parameters, enhancing converter reliability assessments in a non-invasive, generalized, and computationally efficient manner.
The maximum power point tracking (MPPT) algorithm has become an integral part of many charge controllers that are used in photovoltaic (PV) systems. Most of the existing algorithms have a compromise among simplicity, tracking speed, ability to track accurately, and cost. In this work, a novel “straight-line approximation based Maximum Power Point (MPP) finding algorithm” is proposed where the intersections of two linear lines have been utilized to find the MPP, and investigated for its effectiveness in tracking maximum power points in case of rapidly changing weather conditions along with tracking speed using standard irradiance and temperature curves for validation. In comparison with a conventional Perturb and Observe (P&O) method, the Proposed method takes fewer iterations and also, it can precisely track the MPP s even in a rapidly varying weather condition with minimal deviation. The Proposed algorithm is also compared with P&O algorithm in terms of accuracy in duty cycle and efficiency. The results show that the errors in duty cycle and power extraction are much smaller than the conventional P&O algorithm.
9 May 2024 in IEEE Transactions on Industry Applications
This paper presents a novel composite control scheme aimed at ensuring stable and consistent output power in dynamic wireless charging (DWC) systems subject to mutual coupling variations caused by electric vehicle (EV) movement. The proposed control strategy combines backstepping control and second-order sliding mode control, offering both finite-time stability and large-signal stability. The finite-time stability property enhances control robustness and improves disturbance rejection capability, while the large-signal stability feature enables the controller to effectively handle significant disturbances. Furthermore, this paper presents a detailed design procedure for the proposed composite control method, along with stability analysis to demonstrate its finite-time stability property. Simulation and experimental results confirm the effectiveness of the proposed composite controller in stabilizing power at the reference value despite mutual coupling variation and load changes, minimizing fluctuations to just 0.1%. Additionally, the proposed controller consistently maintains an efficiency of 84% across varied positions as the vehicle moves over the transmitter coils.