This work has evaluated the collapse fragility of a typical Chilean building for residential use, structured based on shear-resistant RC walls and inverted beams arranged along its entire perimeter, using the incremental dynamic analysis (IDA) for the evaluation of its structural behavior, using for this the 2018 version of the SeismoStruct software. This method evaluates the global collapse capacity of the building from the graphical representation of its maximum inelastic response, obtained through a non-linear time–history analysis, against the scaled intensity of a set of seismic records obtained in the subduction zone, thus creating the IDA curves of the building. The processing of the seismic records is included within the applied methodology to make them compatible with the elastic spectrum of the Chilean design, achieving an adequate seismic input in the two main structural directions. In addition, an alternative IDA method based on the elongated period is applied to calculate the seismic intensity. The results of the IDA curve obtained with this procedure and the standard IDA analysis are analyzed and compared. The results show that the method relates very well to the structure’s demand and capacity and confirms the non-monotonous behavior exposed by other authors. Regarding the alternative IDA procedure, the results indicate that the method is inadequate, failing to improve the results obtained by the standard method.
Engineering practitioners do not usually include soil-structure interactions in building design; rather, it is common to model and design foundations as embedded joints with joint–based reactions. In some cases, foundation structures are modeled as rigid bodies, embedding the first story into lower vertical elements. Given that the effects of underground floors on the seismic response are not generally included in current building design provisions, it has been little explored in the literature. This work compares and analyzes models to study the effects of different underground stories modeling approaches using earthquake vibration data recorded for the 16–story Alcazar building office in downtown Viña del Mar (Chile). The modeling expands beyond an embedded first story structure to soil with equivalent springs, representing soil-structure interaction (SSI), with varying rigid soil homogeneity. The building was modeled in a finite element software considering only dead load as a static load case because the structure remained in the framing stage when the monitoring system was operating. The instruments registered 72 aftershocks from the 2010 Maule Earthquake, and this study focused on 11 aftershocks of different hypocenters and magnitudes to collect representative information. The comparisons between empirical records and models in this study showed a better fit between the model and the real vibration data for the models that do consider the SSI using horizontal springs attached to the retaining walls of the underground stories. In addition, it was observed that applying a stiffness reduction factor of 0.7 to all elements in deformation verification models for average-height buildings was suitable to analyze the behavior under small earthquakes; better results are obtained embedding the structure in the foundation level than embedding in the street level; the use of horizontal springs with Kuesel’s model with traction for the analysis of the structure yields appropriate results; it is necessary to carefully select the spring constants to be used, paying special attention to the vertical springs. Even though the results presented herein indicate that the use of vertical springs to simulate the SSI of the base slab can result in major differences concerning the real response, it is necessary to obtain more data from instrumentation across a wider variety of structures to continue to evaluate better design and modeling practices. Similarly, further analyses, including nonlinear time-history and high-intensity events, are needed to best regulate building design.
This paper investigates the effect of earthquake ground motion duration on the seismic response of a low‐rise reinforced concrete shear wall building. Two sets of spectrally equivalent ground motion sets were determined to isolate the effect of duration from other earthquake record characteristics. A numerical model that accounts for P‐delta effects and degradation of strength and stiffness of the structural elements was used. Detailed nonlinear dynamic analysis for both the design and collapse levels of shaking was performed, considering the spectral acceleration at the fundamental period of vibration with intensity measure and material strains as engineering demand parameters. The results showed that at the design level of shaking, slightly larger interstory drifts were obtained under the short‐duration events. However, the maximum values for interstory drifts were small, and minor damage is expected in the structure. When both seismic record sets were incrementally scaled until collapse, a slight increase in the material strains was found under the short‐duration seismic events. Overall, it is indicated that ground motion duration does not influence the seismic response of low‐rise buildings with low deformation capacity.
Estimating the dynamic characteristics of instrumented built structures from seismic vibration data collected from built civil structures is essential input information for structural model updating and assessing the health of structures. This study focuses on the earthquake acceleration time histories obtained from several events recorded during its construction phase by accelerometers placed throughout an office building located in Viña del Mar (Chile) to determine its modal features. To this end, the data obtained were analyzed to compare the building’s dynamic properties obtained with two different modal identification techniques. MATLAB programs were developed to implement both methods. The stochastic subspace identification technique for linear systems developed by van Overschee and de Moor was used to study the dynamic properties of the building. In contrast, the nonparametric method employed herein uses correlations and spectral analysis based on the Welch transform in the frequency domain. The investigation demonstrated that both methods identify similar frequencies and that the obtained translational mode shapes exhibit good agreement. Furthermore, the identified frequencies are congruent with the design frequencies.
The purpose of this study is to analyze the nonlinear behavior of a steel warehouse structured by moment-resistant frames, which utilizes an overhead crane on its interior brackets and as an external load of the weight of the lining panels. The analysis methods used are (i) pushover analysis, which consists of applying an incremental force in the transverse and longitudinal direction to obtain the capacity curve of the structure; (ii) time-history analysis, in which different records of destructive earthquakes that occurred in Chile are used in order to analyze the response of the structure to these loads. The results indicate that the transverse direction is more ductile than the Y direction of the structure within the pushover and time-history methods but not using the N2 method. It is also found that most of the columns are within the life safety and collapse prevention criteria. It is concluded that most of the analyses agree with each other and with what is expected, except for the N2 method, which contradicts the results of the time-history analysis, so the N2 method would not be suitable for this type of structure. In addition, it has been determined that the overhead crane loads do not substantially affect the seismic performance of the warehouse.
The design of end-plate connections for steel structures is more loosely specified in Chilean regulations than in American regulations. Nevertheless, eight-bolt extended stiffened (8ES) end-plate connections have not derived benefit from extensive past research, and therefore, their normative recommendations are quite constraining. In this study, both the prequalification and qualification limits are evaluated, and the linear and nonlinear analyses of a connection from a case study focused on a typical industrial structure, characterized by its reduced dimensions, are carried out. For the design of the connection, a spreadsheet was developed based on AISC 358. The nonlinear analysis was modeled using the finite element method, and it is confirmed that the normative recommendations restrict the design in a very conservative way, resulting in oversizing. Finally, a new optimized connection configuration is proposed and analyzed without stiffeners.