Pouya Rezai

Prof. Dr. Pouya Rezai

Department of Mechanical Engineering, Lassonde School of Engineering, York University, RG 433B, 4700 Keele St, Toronto, ON, M3J 1P3, Canada
+1
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
PRPouya Rezai
Pouya Rezai
ASAsad Siddiqui
Asad Siddiqui
P. Ravi SelvaganapathyP. Ravi Selvaganapathy
P. Ravi Selvaganapathy
BGBhagwati Gupta
Bhagwati Gupta
The nematode (worm) Caenorhabditis elegans is one of the most widely studied organisms for biomedical research. Currently, C. elegans assays are performed either on petri dishes, 96-well plates or using pneumatically controlled microfluidic devices. In this work, we demonstrate that the electric field can be used as a powerful stimulus to control movement of worms in a microfluidic environment. We found that this response (termed electrotaxis) is directional, fully penetrant and highly sensitive. The characterization of electrotaxis revealed that it is mediated by neuronal activity that varies with the age and size of animals. Although the speed of swimming is unaffected by changes in the electric field strength and direction, our results show that each developmental stage responds to a specific range of electric field with a specific speed. Finally, we provide evidence that the exposure to the electric field has no discernible effect on the ability of animals to survive and reproduce. Our method has potential in precisely controlling, directing, and transporting worms in an efficient and automated manner. This opens up significant possibilities for high-throughput screening of C. elegans for drug discovery and other applications.

7 June 2018 in Micromachines
Verified
Journal Article
Open access
PDF file
SWShaoxi Wang
Shaoxi Wang
YYYue Yin
Yue Yin
CHChenxia Hu
Chenxia Hu
PRPouya Rezai
Pouya Rezai
Using microfluidic cooling to achieve thermal management of three-dimensional integrated circuits (ICs) is recognized as a promising method of extending Moore law progression in electronic components and systems. Since the U.S. Defense Advanced Research Projects Agency launched Intra/Inter Chip Enhanced Cooling thermal packaging program, the method of using microfluidic cooling in 3D ICs has been under continuous development. This paper presents an analysis of all publications available about the microfluidic cooling technologies used in 3D IC thermal management, and summarized these research works into six categories: cooling structure design, co-design issues, through silicon via (TSV) influence, specific chip applications, thermal models, and non-uniform heating and hotspots. The details of these research works are given, future works are suggested.

1 June 2019 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
MRM. Rahimi
M. Rahimi
AKA. Shams Khorrami
A. Shams Khorrami
PRPouya Rezai
Pouya Rezai

30 March 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
PRPouya Rezai
Pouya Rezai
SSSangeena Salam
Sangeena Salam
P. Ravi SelvaganapathyP. Ravi Selvaganapathy
P. Ravi Selvaganapathy
BGBhagwati P. Gupta
Bhagwati P. Gupta
The nematode (worm) C. elegans is one of the widely studied animal model organisms in biology. It develops through 4 larval stages (L1–L4) in 2 to 3 days before becoming a young adult. Biological assays involving C. elegans frequently require a large number of animals that are appropriately staged and exhibit a similar behaviour. We have developed a new method to synchronize animals that relies on the electrotactic response (electric field-induced motion) of C. elegans to sort them in parallel based on their age, size and phenotype. By using local electric field traps in a microfluidic device, we can efficiently sort worms from a mixed culture in a semi-continuous flow manner (with a minimum throughput of 78 worms per minute per load-run) and obtain synchronized populations of animals. In addition to sorting larvae, our device can also distinguish between young and old adults efficiently. Unlike fluorescent based sorting systems that use active imaging based feedback, this method is passive and automatic and uses the innate behaviour of the worm. Considering that the entire procedure takes only a few minutes to run and is cost-effective, it promises to simplify and accelerate experiments requiring homogeneous cultures of worms as well as to facilitate isolation of mutants that have abnormal electrotaxis. More importantly, our method of isolating and separating worms using locomotion as a defining characteristic promises development of advanced microfluidics-based systems to study the neuronal basis of movement-related defects in worms and facilitate high-throughput chemical screening and drug discovery.

19 July 2016 in Micromachines
Verified
Journal Article
Open access
PDF file
BGBhagwati Gupta
Bhagwati Gupta
PRPouya Rezai
Pouya Rezai
The nematode C. elegans (worm) is a small invertebrate animal widely used in studies related to fundamental biological processes, disease modelling, and drug discovery. Due to their small size and transparent body, these worms are highly suitable for experimental manipulations. In recent years several microfluidic devices and platforms have been developed to accelerate worm handling, phenotypic studies and screens. Here we review major tools and briefly discuss their usage in C. elegans research.

29 April 2019 in Briefings in Functional Genomics
Verified
Journal Article
Closed access
AKArezoo Khalili
Arezoo Khalili
PRPouya Rezai
Pouya Rezai
Zebrafish or Danio rerio is an established model organism for studying the genetic, neuronal and behavioral bases of diseases and for toxicology and drug screening. The embryonic and larval stages of zebrafish have been used extensively in fundamental and applied research due to advantages offered such as body transparency, small size, low cost of cultivation and high genetic homology with humans. However, the manual experimental methods used for handling and investigating this organism are limited due to their low throughput, labor intensiveness and inaccuracy in delivering external stimuli to the zebrafish while quantifying various neuronal and behavioral responses. Microfluidic and lab-on-a-chip devices have emerged as ideal technologies to overcome these challenges. In this review paper, the current microfluidic approaches for investigation of behavior and neurobiology of zebrafish at embryonic and larval stages will be reviewed. Our focus will be to provide an overview of the microfluidic methods used to manipulate (deliver and orient), immobilize and expose or inject zebrafish embryos or larvae, followed by quantification of their responses in terms of neuron activities and movement. We will also provide our opinion in terms of the direction that the field of zebrafish microfluidics is heading toward in the area of biomedical engineering.