Sylwia Dabrowska

Dr. Sylwia Dabrowska

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
BBBartosz Bartoszewicz
Bartosz Bartoszewicz
SDSylwia Dabrowska
Sylwia Dabrowska
Andrzej LewenstamAndrzej Lewenstam
Andrzej Lewenstam
JMJan Migdalski
Jan Migdalski

13 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SDSylwia Dabrowska
Sylwia Dabrowska
JMJan Migdalski
Jan Migdalski
Andrzej LewenstamAndrzej Lewenstam
Andrzej Lewenstam
Polystyrene cross-linked with divinylbenzene and functionalized by a quaternary ammonium cation anion site is used as the membrane of a hydrogencarbonate (i.e., bicarbonate) ion-selective electrode. The polystyrene matrix membrane improves the selectivity towards interfering lipophilic ions in comparison to previously described polyvinyl chloride membranes. The reason for this behaviour is sought in coupled ion-exchange and pore-diffusion processes in the membrane and the resulting kinetic discrimination of interfering ions. The electrode is successfully used for determination of bicarbonates in mineral drinking waters. The simplex method is employed to refine the analytical outcome.

2 November 2016 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
SDSylwia Dabrowska
Sylwia Dabrowska
JMJan Migdalski
Jan Migdalski
Andrzej LewenstamAndrzej Lewenstam
Andrzej Lewenstam

10 May 2023 in Acta Biomaterialia
Verified
Journal Article
Closed access
SDSylwia Dabrowska
Sylwia Dabrowska
MEMartyna Ekiert
Martyna Ekiert
JKJoanna Karbowniczek
Joanna Karbowniczek
WWWładysław Węglarz
Władysław Węglarz
Marcin HeljakMarcin Heljak
Marcin Heljak
AMAndrzej Młyniec
Andrzej Młyniec

10 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SDSylwia Dabrowska
Sylwia Dabrowska
MEMartyna Ekiert
Martyna Ekiert
KWKaja Wójcik
Kaja Wójcik
MKMarek Kalemba
Marek Kalemba
AMAndrzej Młyniec
Andrzej Młyniec
In this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system with good accuracy and repeatability is required. We propose a reliable 3D scanning system consisting of a blue light profile sensor, stationary and rotating frames with stepper motors, gears and a five-phase stepping motor unit, single-axis robot, control system, and replaceable sample grips, which once mounted onto the sample, are used for both scanning and mechanical tests. The proposed system was validated by comparison of the cross-sectional areas calculated based on 3D models, digital caliper, and vision-based methods. Validation was done on regularly-shaped samples, a wooden twig, as well as tendon fascicle bundles. The 3D profiles were used for the development of the 3D computational model of the sample, including surface concavities. Our system allowed for 3D model development of samples with a relative error of less than 1.2% and high repeatability in approximately three minutes. This was crucial for the extraction of the mechanical properties and subsequent inverse analysis, enabling the calibration of complex material models.

21 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
SDSylwia Dabrowska
Sylwia Dabrowska
KGKrzysztof Grabowski
Krzysztof Grabowski
AMAndrzej Młyniec
Andrzej Młyniec
In this work, we investigate the influence of dehydration and subsequent rehydration of tendon fascicle bundles on their structural and mechanical properties by using distilled water, 0.9% NaCl, 10% NaCl, SBF, and double concentrated SBF (SBFx2). The properties of tendon fascicle bundles were investigated by means of uniaxial tests with relaxation periods and hysteresis for samples with various interfascicular matrix content, dissected from the anterior and posterior areas of bovine tendon. Uniaxial tests with relaxation periods and analysis of sample geometry and weight showed that dehydration alters the modulus of elasticity dependent on the interfascicular matrix content and influences the viscoelastic properties of tendon fascicle bundles. Tensile and relaxation tests revealed that changes resulting from excessive sample drying can be reversed by rehydration in an SBF bath solution for elastic strain range above the toe region. Rehydration in SBF solution led to minor differences in mechanical properties when compared to control samples. Moreover, anterior samples with greater interfascicular matrix content, despite their lower stiffness, are less sensitive to sample drying. The obtained results allow us to limit the discrepancies in the measurement of mechanical properties of wet biological samples and can be useful to researchers investigating soft tissue mechanics and the stability of transplant materials.