Jan Migdalski

Jan Migdalski

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2019 in Membranes
Verified
Journal Article
Open access
PDF file
PLPeter Lingenfelter
Peter Lingenfelter
BBBartosz Bartoszewicz
Bartosz Bartoszewicz
JMJan Migdalski
Jan Migdalski
TSTomasz Sokalski
Tomasz Sokalski
MBMirosław M. Bućko
Mirosław M. Bućko
Andrzej LewenstamAndrzej Lewenstam
Andrzej Lewenstam
Several types of liquid membrane and solid-state reference electrodes based on different plastics were fabricated. In the membranes studied, equitransferent organic (QB) and inorganic salts (KCl) are dispersed in polyvinyl chloride (PVC), polyurethane (PU), urea-formaldehyde resin (UF), polyvinyl acetate (PVA), as well as remelted KCl in order to show the matrix impact on the reference membranes’ behavior. The comparison of potentiometic performance was made using specially designed standardized testing protocols. A problem in the reference electrode research and literature has been a lack of standardized testing, which leads to difficulties in comparing different types, qualities, and properties of reference electrodes. Herein, several protocols were developed to test the electrodes’ performance with respect to stability over time, pH sensitivity, ionic strength, and various ionic species. All of the prepared reference electrodes performed well in at least some respect and would be suitable for certain applications as described in the text. Most of the reference types, however, demonstrated some weakness that had not been previously highlighted in the literature, due in large part to the lack of exhaustive and/or consistent testing protocols.

13 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SDSylwia Dabrowska
Sylwia Dabrowska
JMJan Migdalski
Jan Migdalski
Andrzej LewenstamAndrzej Lewenstam
Andrzej Lewenstam
Polystyrene cross-linked with divinylbenzene and functionalized by a quaternary ammonium cation anion site is used as the membrane of a hydrogencarbonate (i.e., bicarbonate) ion-selective electrode. The polystyrene matrix membrane improves the selectivity towards interfering lipophilic ions in comparison to previously described polyvinyl chloride membranes. The reason for this behaviour is sought in coupled ion-exchange and pore-diffusion processes in the membrane and the resulting kinetic discrimination of interfering ions. The electrode is successfully used for determination of bicarbonates in mineral drinking waters. The simplex method is employed to refine the analytical outcome.

1 September 2021 in Talanta
Verified
Journal Article
Open access
MDMarek Dębosz
Marek Dębosz
JKJózsef Kozma
József Kozma
RPRadosław Porada
Radosław Porada
MWMarcin Wieczorek
Marcin Wieczorek
JPJustyna Paluch
Justyna Paluch
PKPaweł Kościelniak
Paweł Kościelniak
Urinalysis is a simple and non-invasive approach for the diagnosis and monitoring of various health disorders. While urinalysis is predominantly confined to clinical laboratories the non-invasive sample collection makes it applicable in wide range of settings outside of central laboratory confinements. In this respect, 3D printed devices integrating sensors for measuring multiple parameters may be one of the most viable approaches to ensure cost-effectiveness for widespread use. Here we evaluated such a system for the multiplexed determination of sodium, potassium and calcium ions in urine samples with ion-selective electrodes based on state of the art octadecylamine-functionalized multi-walled carbon nanotube (OD-MWCNT) solid contacts. The electrodes were tested in the clinically relevant concentration range, i.e. ca. 10-4 - 10-1 mol L-1 and were proven to have Nernstian responses under flow injection conditions. The applicability of the 3D printed flow manifold was investigated through the analysis of synthetic samples and two certified reference materials. The obtained results confirm the suitability of the proposed system for multiplexed ion analysis in urine.

1 July 2014 in Electrochimica Acta
Verified
Journal Article
Closed access
JMJan Migdalski
Jan Migdalski
TBTeresa Błaż
Teresa Błaż
Andrzej LewenstamAndrzej Lewenstam
Andrzej Lewenstam

13 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
Paweł KościelniakPaweł Kościelniak
Paweł Kościelniak
MDMarek Dębosz
Marek Dębosz
MWMarcin Wieczorek
Marcin Wieczorek
JMJan Migdalski
Jan Migdalski
MSMonika Szufla
Monika Szufla
JKJolanta Kochana
Jolanta Kochana
A solid-contact ion-selective electrode was developed for detecting potassium in environmental water. Two versions of a stable cadmium acylhydrazone-based metal organic framework, i.e., JUK-13 and JUK-13_H2O, were used for the construction of the mediation layer. The potentiometric and electrochemical characterizations of the proposed electrodes were carried out. The implementation of the JUK-13_H2O interlayer is shown to improve the potentiometric response and stability of measured potential. The electrode exhibits a good Nernstian slope (56.30 mV/decade) in the concentration range from 10−5 to 10−1 mol L−1 with a detection limit of 2.1 µmol L−1. The long-term potential stability shows a small drift of 0.32 mV h−1 over 67 h. The electrode displays a good selectivity comparable to ion-selective electrodes with the same membrane. The K-JUK-13_H2O-ISE was successfully applied for the determination of potassium in three certified reference materials of environmental water with great precision (RSD < 3.00%) and accuracy (RE < 3.00%).

28 June 2008 in Journal of Solid State Electrochemistry
Verified
Journal Article
Closed access
PDF file
JMJan Migdalski
Jan Migdalski
BBB. Bas
B. Bas
TBT. Blaz
T. Blaz
JGJ. Golimowski
J. Golimowski
Andrzej LewenstamAndrzej Lewenstam
Andrzej Lewenstam