Fábio Melquiades

Dr. Fábio Melquiades

Londrina State University, Londrina, Paraná, Brazil
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2004 in Journal of Radioanalytical and Nuclear Chemistry
Verified
Journal Article
Closed access
PDF file
FMFábio Melquiades
Fábio Melquiades
Carlos Roberto AppoloniCarlos Roberto Appoloni
Carlos Roberto Appoloni

17 March 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Tiago TavaresTiago Tavares
Tiago Tavares
Jose MolinJose Molin
Jose Molin
LNLidiane Cristina Nunes
Lidiane Cristina Nunes
Elton Eduardo Novais AlvesElton Eduardo Novais Alves
Elton Eduardo Novais Alves
FMFábio Melquiades
Fábio Melquiades
AMAbdulmounem Mouazen
Abdulmounem Mouazen
The successful use of energy-dispersive X-ray fluorescence (ED-XRF) sensors for soil analysis requires the selection of an optimal procedure of data acquisition and a simple modelling approach. This work aimed at assessing the performance of a portable XRF (XRF) sensor set up with two different X-ray tube configurations (combinations of voltage and current) to predict nine key soil fertility attributes: (clay, organic matter (OM), cation exchange capacity (CEC), pH, base saturation (V), and extractable nutrients (P, K, Ca, and Mg). An XRF, operated at a voltage of 15 kV (and current of 23 μA) and 35 kV (and current of 7 μA), was used for analyzing 102 soil samples collected from two agricultural fields in Brazil. Two different XRF data analysis scenarios were used to build the predictive models: (i) 10 emission lines of 15 keV spectra (EL-15), and (ii) 12 emission lines of 35 keV spectra (EL-35). Multiple linear regressions (MLR) were used for model calibration, and the models’ prediction performance was evaluated using different figures of merit. The results show that although X-ray tube configuration affected the intensity of the emission lines of the different elements detected, it did not influence the prediction accuracy of the studied key fertility attributes, suggesting that both X-ray tube configurations tested can be used for future analyses. Satisfactory predictions with residual prediction deviation (RPD) ≥ 1.54 and coefficient of determination (R2) ≥ 0.61 were obtained for eight out of the ten studied soil fertility attributes (clay, OM, CEC, V, and extractable K, Ca, and Mg). In addition, simple MLR models with a limited number of emission lines was effective for practical soil analysis of the key soil fertility attributes (except pH and extractable P) using XRF. The simple and transparent methodology suggested also enables future researches that seek to optimize the XRF scanning time in order to speed up the XRF analysis in soil samples.

30 May 2012 in X-Ray Spectrometry
Verified
Journal Article
Closed access
PDF file
RBR. O. Bastos
R. O. Bastos
FMFábio Melquiades
Fábio Melquiades
GBG. E. V. Biasi
G. E. V. Biasi

1 April 2008 in Analytica Chimica Acta
Verified
Journal Article
Closed access
FMFábio Melquiades
Fábio Melquiades
DFD.D. Ferreira
D.D. Ferreira
Carlos Roberto AppoloniCarlos Roberto Appoloni
Carlos Roberto Appoloni
Fabio LopesFabio Lopes
Fabio Lopes
Audrey Alesandra Stinghen Garcia LonniAudrey Alesandra Stinghen Garcia Lonni
Audrey Alesandra Stinghen Garcia Lonni
JDJ.C. Duarte
J.C. Duarte

1 February 2022 in Soil and Tillage Research
Verified
Journal Article
Closed access
TTTiago R. Tavares
Tiago R. Tavares
AMAbdul M. Mouazen
Abdul M. Mouazen
LNLidiane C. Nunes
Lidiane C. Nunes
FSFelipe R. dos Santos
Felipe R. dos Santos
FMFábio Melquiades
Fábio Melquiades
JMJosé P. Molin
José P. Molin

1 December 2017 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
FMFranslley Morona
Franslley Morona
FSFELIPE RODRIGUES DOS SANTOS
FELIPE RODRIGUES DOS SANTOS
ABAndré M. Brinatti
André M. Brinatti
FMFábio Melquiades
Fábio Melquiades