Łukasz Kozarek

Mr. Łukasz Kozarek

ILF Consulting Engineers
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
Michał SzulborskiMichał Szulborski
Michał Szulborski
SŁSebastian Łapczyński
Sebastian Łapczyński
Łukasz KolimasŁukasz Kolimas
Łukasz Kolimas
ŁKŁukasz Kozarek
Łukasz Kozarek
DRDesire Dauphin Rasolomampionona
Desire Dauphin Rasolomampionona
Proper busbar selection based on analytical calculations is of great importance in terms of power grid functioning and its safe usage. Experimental tests concerning busbars are very expensive and difficult to be executed. Therefore, the great advantage for setting the valid parameters for busbar systems components are analytical calculations supported by FEM (finite element method) modelling and analysis. Determining electrodynamic forces in busbar systems tends to be crucial with regard to subsidiary, dependent parameters. In this paper analytical calculations of asymmetric three-phase busbar system were carried out. Key parameters, like maximal electrodynamic forces value, mechanical strength value, busbar natural frequency, etc., were calculated. Calculations were conducted with an ANSYS model of a parallel asymmetric busbar system, which confirmed the obtained results. Moreover, showing that a model based on finite elements tends to be very helpful in the selection of unusually-shaped busbars in various electrotechnical applications, like switchgear.

23 May 2024 in IEEE Access
Verified
Journal Article
Open access
Michał SzulborskiMichał Szulborski
Michał Szulborski
SŁSebastian Łapczyński
Sebastian Łapczyński
Łukasz KolimasŁukasz Kolimas
Łukasz Kolimas
ŁKŁukasz Kozarek
Łukasz Kozarek
HCHubert Cichecki
Hubert Cichecki
MWMarcin Wesołowski
Marcin Wesołowski
Paper concerns the novel modelling technology called Digital Twin in aspect of physical phenomenon simulation analysis. Digital Twin model concerning electrodynamic forces in three-phase high voltage disconnector was presented, validated and discussed. Experiences related to laboratory work and measurement of electrodynamic forces clearly showed that often, despite the use of modern computing machines, the research process is hard, very expensive and values of electrodynamic forces are almost impossible to measure in real scale conditions. Hence the idea to use very advanced field models minimized to a reduced order model (ROM), using the Digital Twin Technology seemed valid and rendered possibilities for advancements concerning this type of research. Due to the large weight of devices (chokes, transformers, disconnectors) on high-voltage networks it is often time-consuming or even impossible to perform the entire simulation. Proposed modelling approach helps to obtain results from very complex models also for long-term thermal tests. The reduced order model can be used not only by researchers, but also in the development departments of enterprises. Digital Twin model results were compared and validated with values derived from short-circuit tests made in Institute of Power Engineering, Research Institute.

25 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
SŁSebastian Łapczyński
Sebastian Łapczyński
Michał SzulborskiMichał Szulborski
Michał Szulborski
KGKarol Gołota
Karol Gołota
Łukasz KolimasŁukasz Kolimas
Łukasz Kolimas
ŁKŁukasz Kozarek
Łukasz Kozarek
The purpose of this work is to discuss the tulip contact behavior during mechanical and electrical simulations in a Finite Element Method (FEM) environment using ANSYS and COMSOL software. During the simulations, the full contact movement was analyzed. During the contact movement, the individual behavior of the contact components was taken into consideration. The motion simulation was carried out at different velocities and forces acting on the contact. The obtained results were compared to each other and discussed. Relatively, the angles of the contact surfaces to each other were also changed, which meant that we could conduct a more in-depth analysis. The other approach of simulation research was a field analysis of physical phenomena occurring in the tulip contact. This analysis was performed in COMSOL Multiphysics. Parametric analysis allowed an observation of the electric field in the tulip contact at different contact distances with respect to each other. This work is important in terms of the cost effectiveness for design procedures concerning tulip contacts and fault avoidance, which both result from mechanical and electrical conditions throughout contact exploitation and optimization of the working conditions for the tulip contact.

17 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
KBKrzysztof Bieńkowski
Krzysztof Bieńkowski
SŁSebastian Łapczyński
Sebastian Łapczyński
Michał SzulborskiMichał Szulborski
Michał Szulborski
ŁKŁukasz Kozarek
Łukasz Kozarek
KGKarol Gołota
Karol Gołota
MOMaciej Owsiński
Maciej Owsiński
The aim of this work was to develop a parameterized analytical and FEM (Finite Element Method) model of a switched reluctance motor. The developed analytical model was used to assess the performance of these types of motors, and is determined to be a tool for comparing and evaluating switched reluctance motors of various designs. The aim of the work was also the systematization of knowledge related to the operation, structure and methods of determining the static electromagnetic torque generated by switched reluctance motors. The FEM model (ANSYS) was, also, made in order to verify physical phenomena occurring during operation of these motors. Four laboratory tests were executed as part of the work prototypes of switched reluctance motors built at Warsaw University of Technology. A parameterized analytical model was developed and implemented in MATLAB. The model operation tests were conducted and as a result, the characteristics describing the dependence of the electromagnetic torque as a function of the current and the position of the rotor were obtained. The model was validated by confronting the analytical calculations supported by FEM simulation results with the measurement results. The usefulness of the results obtained with the use of the procured models was assessed.

14 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
ŁKŁukasz Kozarek
Łukasz Kozarek
HCHubert Cichecki
Hubert Cichecki
MBMateusz Bogacki
Mateusz Bogacki
MTMykhailo Tyryk
Mykhailo Tyryk
Michał SzulborskiMichał Szulborski
Michał Szulborski
MOMaciej Owsiński
Maciej Owsiński
This paper focuses on determining the effects of short-circuit current values on the operation of high-voltage substations. The analyses performed focused on the dynamic and thermal effects on the short-circuit current for different input data configurations. The analyses of the dynamic effects of short-circuit current were performed in two ways. First, calculations were executed using the procedures contained in “IEC 60865-1:2012 Short-circuit currents, calculations of the effects of short-circuit currents. Part 1: Definitions and calculation methods”. Analytic calculations were accomplished for different values of the initial three-phase short-circuit current, the type of short circuit, the static tension force of the conductors, the stiffness of the structure and the methods of attaching the lashing chains. Secondly, the same analysis was performed using PRIMTECH 3D software. The connections were modeled in computer software, for which the calculations were implemented according to normative recommendations. After obtaining the results, an analysis was performed using the model based on the input data. Performing the analysis in two ways made it possible to compare the results with each other and develop conclusions. An analysis of the thermal effects of the short-circuit current was also provided. The results of the calculations showed that the choice of conductor cross sections according to the value of the initial short-circuit current was correct. Particular attention has been paid to rigid conductors and flexible conductors, which are directly affected by the short circuit and have an impact on the selection of the complete equipment for the high-voltage switchgear.

4 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
Michał SzulborskiMichał Szulborski
Michał Szulborski
SŁSebastian Łapczyński
Sebastian Łapczyński
Łukasz KolimasŁukasz Kolimas
Łukasz Kolimas
ŁKŁukasz Kozarek
Łukasz Kozarek
DRDesire Dauphin Rasolomampionona
Desire Dauphin Rasolomampionona
ASAdam Smolarczyk
Adam Smolarczyk
In this paper, a detailed three-dimensional, transient, finite element method of fuse link NH000 gG 100 A is proposed. The thermal properties during the operation of the fuses under nominal (100 A) and custom conditions (110 and 120 A) are the main focus of the analyses that were conducted. The work concerns both the outside elements of the fuse link (ceramic body) and the elements inside (current circuit). Both the distribution of the electric current and its impact on the temperature of the construction parts of the fuses during their operating mode have been described. Temperature distribution, power losses and energy dissipation were measured using a numerical model. In order to verify and validate the model, two independent teams of scientists executed experimental research, during which the temperature was measured on different parts of the device involving the rated current. Finally, the two sets of results were put together and compared with those obtained from the simulation tests. A possible significant correlation between the results of the empirical tests and the simulation work was highlighted.