Rodrigo Arturo Marquet Rivera

Dr. Rodrigo Arturo Marquet Rivera

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
RRRodrigo Arturo Marquet Rivera
Rodrigo Arturo Marquet Rivera
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
RHRosa Alicia Hernández-Vázquez
Rosa Alicia Hernández-Vázquez
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
OMOctavio Alejandro Mastache-Miranda
Octavio Alejandro Mastache-Miranda
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
The modelling of biological structures has allowed great advances in Engineering, Biology, and Medicine. In turn, these advances are seen from the design of footwear and sports accessories, to the design of prostheses, accessories and rehabilitation treatments. The reproduction of the various tissues has gone through an important evolution thanks to the development of computer systems and programs. However, knowledge of the medical‐biological and engineering areas continues to be required, and it involves a considerable investment of time and resources. The resulting biomodels still require great precision. The present work shows a methodology that allows to optimize computational resources and reduce elaboration time of biomodels. Through this methodology, it is possible to generate a biomodel of high biofidelity of a human knee. This biomodel is constituted by hard tissues (cortical and trabecular bones) and soft tissues (ligaments and meniscus) resulting in the modelling of the lower third of the femur, the tibial plateaus, the anterior cruciate ligament, posterior cruciate ligament, external lateral ligament, interior lateral ligaments, and the meniscus. With this model and methodology, it is possible to perform numerical analyses that will provide results very similar to those of real life. As, the methodology allows to assign the mechanical properties to each tissue and the anatomical structure.

28 January 2020 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
RHRosa Alicia Hernández-Vázquez
Rosa Alicia Hernández-Vázquez
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
RRRodrigo Arturo Marquet Rivera
Rodrigo Arturo Marquet Rivera
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
OMOctavio Alejandro Mastache-Miranda
Octavio Alejandro Mastache-Miranda
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
Experimental research on living beings faces several obstacles, which are more than ethical and moral issues. One of the proposed solutions to these situations is the computational modelling of anatomical structures. The present study shows a methodology for obtaining high-biofidelity biomodels, where a novel imagenological technique is used, which applies several CAM/CAD computer programs that allow a better precision for obtaining a biomodel, with highly accurate morphological specifications of the molar and tissues that shape the biomodel. The biomodel developed is the first lower molar subjected to a basic chewing simulation through the application of the finite element method, resulting in a viable model, able to be subjected to various simulations to analyse molar biomechanical characteristics, as well as pathological conditions to evaluate restorative materials and develop treatment plans. When research is focused in medical and dental investigation aspects, numerical analyses could allow the implementation of several tools commonly used by mechanical engineers to provide new answers to old problems in these areas. With this methodology, it is possible to perform high-fidelity models no matter the size of the anatomical structure, nor the complexity of its structure and internal tissues. So, it can be used in any area of medicine.

Verified
Journal Article
Open access
PDF file
JPJesus Alejandro Serrato Pedrosa
Jesus Alejandro Serrato Pedrosa
IVIgnacio Villanueva
Ignacio Villanueva
RRRodrigo Arturo Marquet Rivera
Rodrigo Arturo Marquet Rivera
RHRosa Alicia Hernández-Vázquez
Rosa Alicia Hernández-Vázquez
SLSalvador Cruz López
Salvador Cruz López
Veronica Loera-CastañedaVeronica Loera-Castañeda
Veronica Loera-Castañeda
The widely available options of different manufacturers in dental implant systems have complicated the selection criteria process for periodontists, necessitating careful consideration of various factors when selecting suitable solutions for individual patient needs. Optimal implant selection requires careful consideration of the patient-specific factors, implant design, and surgical technique. Understanding the biomechanical behavior of implant–tissue interactions is crucial for achieving successful and long-lasting implant therapy. To adequately address this issue and improve the rigorous selection criteria from a biomechanically numerical approach, this research aims to analyze the stress distribution fields, strain patterns, and load transfer displacements within the implant system and the implant–biological interface (gingival and bony tissues) of titanium three-piece to two–one-piece ceramic implant systems. Thus, three different commercially available dental implants designed to be placed in the jaw molar region were considered for evaluation through the finite element method under both oblique and occlusal loading conditions. The results have exhibited an increasing trend to highlight the outstanding behavior of two-piece ceramic implants to dissipate the stress distribution better (6 and 2 times lower than the three- and one-piece systems under occlusal loads and almost 5 and 1.3 times more efficient for oblique loading, respectively), minimize peak stress values (below 100 MPa), and reduce strain peak patterns compared with the other two evaluated designs. On the other hand, the effects generated in biological tissues are strongly associated with implant geometry features. This biomechanical approach could provide a promising strategy for predicting micro-strains and micromotion in implant system pieces and geometries. Hence, these findings contribute to a deeper understanding of the biomechanics spectrum in the behavior of dental implant systems and emphasize the importance of carefully selecting appropriate material systems for accurate patient-specific biomechanical performance.

24 July 2021 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
RRRodrigo Arturo Marquet Rivera
Rodrigo Arturo Marquet Rivera
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
RHRosa Alicia Hernández-Vázquez
Rosa Alicia Hernández-Vázquez
OMOctavio Alejandro Mastache-Miranda
Octavio Alejandro Mastache-Miranda
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
Nowadays, cruciate ligament injuries have increased in incidence, since practicing a sport or physical activity has become a trend in current societies. Although this lifestyle generates multiple benefits, as a consequence, injury has also increased. Due to its nature and complexity, the ligaments of the knee are those that are most frequently affected, mainly the ACL (anterior cruciate ligament). This tissue reacts to overexertion or movements out of range, either caused by the exercise itself or caused by trauma caused by the practice of physical activity, causing various degrees of sprain. Whatever the etiology of these injuries, they will require a therapy indicated for each degree of injury. This therapy initially entails immobilization of the affected area and later; physical therapy will be required to a lesser or greater degree. Commonly, in the physiotherapy of these injuries, rehabilitation exercises are prescribed, where the physiotherapist asks a patient to use equipment with an estimated weight. However, the effectiveness of a generalized therapy in this way does not always give the expected results. This is related to the fact that these therapies are standardized and do not consider some factors such as the remaining muscle fibres that are not directly affected by the sprain, which does not mean that they should not be considered. Therefore, in the present work, a biomodel of a human knee has been developed and used to evaluate numerically how the ACL acts under an external load, when there are different degrees of injuries, caused by trauma. Four case studies were considered: Case 1 (control case) where the ACL is healthy, Case 2 where the ACL presents a 1st-degree sprain, Case 3 where the ACL presents a 2nd-degree sprain, and finally Case 4 where the ACL presents a 3rd-sprain grade. After performing the analyses, in the control case, it was found that it presents a balance between tensile and compressive stresses. While in the 4th case, the most critical tensile stress decreases while compression stresses increase. This shows that the ligament, having considerable damage, no longer works as it should and can eventually damage the collateral structures. It was found that, when there was a sprain, where the continuity of the ligament is compromised, a second torsional moment occurs in the ACL which causes the tissue fibres not to act according to their normal physiology or in a healthy state. The results obtained from the present study provide the possibility of predicting where the following injuries will occur by considering the von Mises failure criterion. Likewise, they will allow to improve the therapeutic procedures considering not only the injured structure but also the system as a whole.

5 September 2019 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
RHRosa Alicia Hernández-Vázquez
Rosa Alicia Hernández-Vázquez
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
RRRodrigo Arturo Marquet Rivera
Rodrigo Arturo Marquet Rivera
BRBeatriz Romero-Ángeles
Beatriz Romero-Ángeles
OMOctavio-Alejandro Mastache-Miranda
Octavio-Alejandro Mastache-Miranda
GUG. Guillermo Urriolagoitia-Calderón
G. Guillermo Urriolagoitia-Calderón
When it is about restorative dental materials, aesthetics is traditionally preferred. This has led to the selection of materials very visually similar to the enamel, but unfortunately, their mechanical properties are not similar. This often translates into disadvantages than advantages. In the present work, a comparison is made of the stresses that occur during dental occlusion (dental bit) in a healthy dental organ and those that are generated in a dental organ with a dental zirconium restoration. Numerical simulation was carried out by means of the Finite Element Method, in computational biomodels, from Cone-Beam Tomography, to obtain the stresses generated during dental occlusion. It was found that the normal and von Mises stresses generated are substantially greater in the molar with restoration compared to those produced in the healthy molar. In addition, the normal function of the enamel and dentin to disperse these stresses to prevent them from reaching the pulp is altered. Therefore, it is necessary to analyze the indiscriminate use of this restoration material and consider other aspects, in addition to aesthetics and biocompatibility for the choice of restorative materials such as biomechanical compatibility.

25 March 2021 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
RHRosa Alicia Hernández-Vázquez
Rosa Alicia Hernández-Vázquez
RRRodrigo Arturo Marquet Rivera
Rodrigo Arturo Marquet Rivera
OMOctavio Alejandro Mastache-Miranda
Octavio Alejandro Mastache-Miranda
AVAngel Javier Vázquez-López
Angel Javier Vázquez-López
SLSalvador Cruz López
Salvador Cruz López
JFJuan Alejandro Vazquez Feijoo
Juan Alejandro Vazquez Feijoo
In the lingual orthodontic technique, there are two paradigms regarding the type of wire used. Regardless of the material or gauge, some orthodontists choose to use the straight wire and resin and bond it to the surface of the tooth; they call it compensations. Other orthodontists prefer to bend the wire, giving it a mushroom shape. There is no specific indication for the use of each type of wire, so orthodontists use them according to their criteria. The present study establishes the bases so that it is possible to find the indications for each type of wire. A clinical trial of a lingual orthodontic patient was used. To carry out the comparative study, a straight arch was placed in his right arch and a mushroom arch in the left arch. Using 3D imaging, a high-biofidelity biomodel of the patient’s mandible was generated, with which the FEM analysis was performed, which allowed comparing the reactions of the mandibular bone and appliances with the different arches. It was found that, on the side with the straight arch, there were greater deformations, and in the mushroom arch, there were greater stresses. With this, it is possible to find which clinical cases in each type of wire are indicated.