Salvador Cruz López

Dr. Salvador Cruz López

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JPJesus Alejandro Serrato Pedrosa
Jesus Alejandro Serrato Pedrosa
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
SLSalvador Cruz López
Salvador Cruz López
GMGuadalupe Murillo-Aleman
Guadalupe Murillo-Aleman
Plantar pressure distribution is a thoroughly recognized parameter for evaluating foot structure and biomechanical behavior, as it is utilized to determine musculoskeletal conditions and diagnose foot abnormalities. Experimental testing is currently being utilized to investigate static foot conditions using invasive and noninvasive techniques. These methods are usually expensive and laborious, and they lack valuable data since they only evaluate compressive forces, missing the complex stress combinations the foot undergoes while standing. The present investigation applied medical and engineering methods to predict pressure points in a healthy foot soft tissue during normal standing conditions. Thus, a well-defined three-dimensional foot biomodel was constructed to be numerically analyzed through medical imaging. Two study cases were developed through a structural finite element analysis. The first study was developed to evaluate barefoot behavior deformation and stresses occurring in the plantar region. The results from this analysis were validated through baropodometric testing. Subsequently, a customized 3D model total-contact foot orthosis was designed to redistribute peak pressures appropriately, relieving the plantar region from excessive stress. The results in the first study case successfully demonstrated the prediction of the foot sole regions more prone to suffer a pressure concentration since the values are in good agreement with experimental testing. Employing a customized insole proved to be highly advantageous in fulfilling its primary function, reducing peak pressure points substantially. The main aim of this paper was to provide more precise insights into the biomechanical behavior of foot pressure points through engineering methods oriented towards innovative assessment for absolute customization for orthotic devices.

Verified
Journal Article
Open access
PDF file
JPJesus Alejandro Serrato Pedrosa
Jesus Alejandro Serrato Pedrosa
IVIgnacio Villanueva
Ignacio Villanueva
RRRodrigo Arturo Marquet Rivera
Rodrigo Arturo Marquet Rivera
RHRosa Alicia Hernández-Vázquez
Rosa Alicia Hernández-Vázquez
SLSalvador Cruz López
Salvador Cruz López
Veronica Loera-CastañedaVeronica Loera-Castañeda
Veronica Loera-Castañeda
The widely available options of different manufacturers in dental implant systems have complicated the selection criteria process for periodontists, necessitating careful consideration of various factors when selecting suitable solutions for individual patient needs. Optimal implant selection requires careful consideration of the patient-specific factors, implant design, and surgical technique. Understanding the biomechanical behavior of implant–tissue interactions is crucial for achieving successful and long-lasting implant therapy. To adequately address this issue and improve the rigorous selection criteria from a biomechanically numerical approach, this research aims to analyze the stress distribution fields, strain patterns, and load transfer displacements within the implant system and the implant–biological interface (gingival and bony tissues) of titanium three-piece to two–one-piece ceramic implant systems. Thus, three different commercially available dental implants designed to be placed in the jaw molar region were considered for evaluation through the finite element method under both oblique and occlusal loading conditions. The results have exhibited an increasing trend to highlight the outstanding behavior of two-piece ceramic implants to dissipate the stress distribution better (6 and 2 times lower than the three- and one-piece systems under occlusal loads and almost 5 and 1.3 times more efficient for oblique loading, respectively), minimize peak stress values (below 100 MPa), and reduce strain peak patterns compared with the other two evaluated designs. On the other hand, the effects generated in biological tissues are strongly associated with implant geometry features. This biomechanical approach could provide a promising strategy for predicting micro-strains and micromotion in implant system pieces and geometries. Hence, these findings contribute to a deeper understanding of the biomechanics spectrum in the behavior of dental implant systems and emphasize the importance of carefully selecting appropriate material systems for accurate patient-specific biomechanical performance.

24 July 2021 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
RRRodrigo Arturo Marquet Rivera
Rodrigo Arturo Marquet Rivera
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
BRBeatriz Romero-Angeles
Beatriz Romero-Angeles
RHRosa Alicia Hernández-Vázquez
Rosa Alicia Hernández-Vázquez
OMOctavio Alejandro Mastache-Miranda
Octavio Alejandro Mastache-Miranda
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
Nowadays, cruciate ligament injuries have increased in incidence, since practicing a sport or physical activity has become a trend in current societies. Although this lifestyle generates multiple benefits, as a consequence, injury has also increased. Due to its nature and complexity, the ligaments of the knee are those that are most frequently affected, mainly the ACL (anterior cruciate ligament). This tissue reacts to overexertion or movements out of range, either caused by the exercise itself or caused by trauma caused by the practice of physical activity, causing various degrees of sprain. Whatever the etiology of these injuries, they will require a therapy indicated for each degree of injury. This therapy initially entails immobilization of the affected area and later; physical therapy will be required to a lesser or greater degree. Commonly, in the physiotherapy of these injuries, rehabilitation exercises are prescribed, where the physiotherapist asks a patient to use equipment with an estimated weight. However, the effectiveness of a generalized therapy in this way does not always give the expected results. This is related to the fact that these therapies are standardized and do not consider some factors such as the remaining muscle fibres that are not directly affected by the sprain, which does not mean that they should not be considered. Therefore, in the present work, a biomodel of a human knee has been developed and used to evaluate numerically how the ACL acts under an external load, when there are different degrees of injuries, caused by trauma. Four case studies were considered: Case 1 (control case) where the ACL is healthy, Case 2 where the ACL presents a 1st-degree sprain, Case 3 where the ACL presents a 2nd-degree sprain, and finally Case 4 where the ACL presents a 3rd-sprain grade. After performing the analyses, in the control case, it was found that it presents a balance between tensile and compressive stresses. While in the 4th case, the most critical tensile stress decreases while compression stresses increase. This shows that the ligament, having considerable damage, no longer works as it should and can eventually damage the collateral structures. It was found that, when there was a sprain, where the continuity of the ligament is compromised, a second torsional moment occurs in the ACL which causes the tissue fibres not to act according to their normal physiology or in a healthy state. The results obtained from the present study provide the possibility of predicting where the following injuries will occur by considering the von Mises failure criterion. Likewise, they will allow to improve the therapeutic procedures considering not only the injured structure but also the system as a whole.

25 March 2021 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
RHRosa Alicia Hernández-Vázquez
Rosa Alicia Hernández-Vázquez
RRRodrigo Arturo Marquet Rivera
Rodrigo Arturo Marquet Rivera
OMOctavio Alejandro Mastache-Miranda
Octavio Alejandro Mastache-Miranda
AVAngel Javier Vázquez-López
Angel Javier Vázquez-López
SLSalvador Cruz López
Salvador Cruz López
JFJuan Alejandro Vazquez Feijoo
Juan Alejandro Vazquez Feijoo
In the lingual orthodontic technique, there are two paradigms regarding the type of wire used. Regardless of the material or gauge, some orthodontists choose to use the straight wire and resin and bond it to the surface of the tooth; they call it compensations. Other orthodontists prefer to bend the wire, giving it a mushroom shape. There is no specific indication for the use of each type of wire, so orthodontists use them according to their criteria. The present study establishes the bases so that it is possible to find the indications for each type of wire. A clinical trial of a lingual orthodontic patient was used. To carry out the comparative study, a straight arch was placed in his right arch and a mushroom arch in the left arch. Using 3D imaging, a high-biofidelity biomodel of the patient’s mandible was generated, with which the FEM analysis was performed, which allowed comparing the reactions of the mandibular bone and appliances with the different arches. It was found that, on the side with the straight arch, there were greater deformations, and in the mushroom arch, there were greater stresses. With this, it is possible to find which clinical cases in each type of wire are indicated.

20 February 2024 in Advances in Science and Technology
Verified
Conference Paper
Closed access
PDF file
SLSalvador Cruz López
Salvador Cruz López
GUGuillermo Manuel Urriolagoitia-Calderón
Guillermo Manuel Urriolagoitia-Calderón
BRBeatriz Romero-Ángeles
Beatriz Romero-Ángeles
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
RMRodrigo Arturo Marquet-Rivera
Rodrigo Arturo Marquet-Rivera
OMOctavio Alejandro Mastache-Miranda
Octavio Alejandro Mastache-Miranda
The development of arthropod-inspired robotic architecture, modeled after the limbs of insects and other animals, has enabled robots to behave more flexibly and adaptively in different environments. Among these designs, hexapod robots have gained significant attention due to their potential use in disaster rescue scenarios, providing vital support for lifesaving and damage control in emergency situations. This study addresses the numerical analysis of a hexapod robot specifically tailored for use in disaster areas, with a particular focus on the crucial aspect of material optimization. Hexapod robots, equipped with articulated legs that mimic insect-like movements, have shown remarkable success in exploration tasks, especially in navigating hard-to-reach places. The main body of the robot was designed using durable yet lightweight materials to optimize load-bearing capacity for the required equipment and rescue tools. A thorough static numerical analysis was performed to ensure the structural integrity and efficiency of the robot. Finite element simulation programs were used for the static numerical analysis, allowing evaluation of the stresses and deformations to which the robot would be subjected under various loading conditions. The selection of materials played a critical role in improving the robot's performance and survivability during disaster operations. Various materials, including composites and advanced alloys, were tested, and analyzed for their mechanical properties and suitability for harsh conditions. In particular, the resistance of the robot to the impact of a falling cubic reinforced concrete element was investigated by simulating a stone collapse. The results of this study shed light on the influence of materials on the robot's ability to cope with unpredictable and challenging scenarios, ultimately contributing to the development of more robust and reliable Hexapod robots for disaster operations. The results of this research contribute significantly to ongoing advances in robotics technology for disaster operations. By leveraging the unique characteristics of arthropod-inspired Hexapod robots and optimizing their material composition, this study highlights the potential of these mobile devices to revolutionize rescue operations in challenging and hazardous environments, ultimately saving lives and minimizing the impact of disasters.