Akira Kon

Dr. Akira Kon


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2023 in Photonics
Verified
Journal Article
Open access
PDF file
Hiromitsu KiriyamaHiromitsu Kiriyama
Hiromitsu Kiriyama
Yasuhiro MIYASAKAYasuhiro MIYASAKA
Yasuhiro MIYASAKA
AKAkira Kon
Akira Kon
MNMamiko Nishiuchi
Mamiko Nishiuchi
ASAkito Sagisaka
Akito Sagisaka
USUlrich Schramm
Ulrich Schramm
We described the output performance and temporal quality enhancement of the J-KAREN-P petawatt laser facility. After wavefront correction using a deformable mirror, focusing with an f/1.3 off-axis parabolic mirror delivered a peak intensity of 1022 W/cm2 at 0.3 PW power levels. Technologies to improve the temporal contrast were investigated and tested. The origins of pre-pulses generated by post-pulses were identified and the elimination of most pre-pulses by removal of the post-pulses with wedged optics was achieved. A cascaded femtosecond optical parametric amplifier based on the utilization of the idler pulse rather than the signal pulse was developed for the complete elimination of the remaining pre-pulses. The orders of magnitude enhancement of the pedestal before the main pulse were obtained by using a higher surface quality of the convex mirror in the Öffner stretcher. A single plasma mirror was installed in the J-KAREN-P laser beam line for further contrast improvement of three orders of magnitude. The above developments indicate, although it has not been directly measured, the contrast can be as high as approximately 1015 up to 40 ps before the main pulse. We also showed an overview of the digital transformation (DX) of the system, enabling remote and automated operation of the J-KAREN-P laser facility.

22 September 2020 in Crystals
Verified
Journal Article
Open access
PDF file
SBStefan Bock
Stefan Bock
FHFranziska Marie Herrmann
Franziska Marie Herrmann
TPThomas Püschel
Thomas Püschel
UHUwe Helbig
Uwe Helbig
RGRené Gebhardt
René Gebhardt
USUlrich Schramm
Ulrich Schramm
We report on a new approach to measure the accumulated B-integral in the regenerative and multipass amplifier stages of ultrashort-pulse high-power laser systems by B-integral-induced coupling between delayed test post-pulses and the main pulse. A numerical model for such non-linear pulse coupling is presented and compared to data taken at the high-power laser Draco with self-referenced spectral interferometry (SRSI). The dependence of the B-integral accumulated in the regenerative amplifier on its operation mode enables optimization strategies for extracted energy vs. collected B-integral. The technique presented here can, in principle, be applied to characterize any type of ultrashort pulse laser system and is essential for pre-pulse reduction.

3 September 2020 in Crystals
Verified
Journal Article
Open access
PDF file
Hiromitsu KiriyamaHiromitsu Kiriyama
Hiromitsu Kiriyama
APAlexander Pirozhkov
Alexander Pirozhkov
MNMamiko Nishiuchi
Mamiko Nishiuchi
Yuji FukudaYuji Fukuda
Yuji Fukuda
ASAkito Sagisaka
Akito Sagisaka
USUlrich Schramm
Ulrich Schramm
Ultra-high intensity femtosecond lasers have now become excellent scientific tools for the study of extreme material states in small-scale laboratory settings. The invention of chirped-pulse amplification (CPA) combined with titanium-doped sapphire (Ti:sapphire) crystals have enabled realization of such lasers. The pursuit of ultra-high intensity science and applications is driving worldwide development of new capabilities. A petawatt (PW = 1015 W), femtosecond (fs = 10−15 s), repetitive (0.1 Hz), high beam quality J-KAREN-P (Japan Kansai Advanced Relativistic ENgineering Petawatt) Ti:sapphire CPA laser has been recently constructed and used for accelerating charged particles (ions and electrons) and generating coherent and incoherent ultra-short-pulse, high-energy photon (X-ray) radiation. Ultra-high intensities of 1022 W/cm2 with high temporal contrast of 10−12 and a minimal number of pre-pulses on target has been demonstrated with the J-KAREN-P laser. Here, worldwide ultra-high intensity laser development is summarized, the output performance and spatiotemporal quality improvement of the J-KAREN-P laser are described, and some experimental results are briefly introduced.

24 June 2022 in High Power Laser Science and Engineering
Verified
Journal Article
Open access
PDF file
AKAkira Kon
Akira Kon
MNMamiko Nishiuchi
Mamiko Nishiuchi
Yuji FukudaYuji Fukuda
Yuji Fukuda
KKKotaro Kondo
Kotaro Kondo
KOKoichi Ogura
Koichi Ogura
Hiromitsu KiriyamaHiromitsu Kiriyama
Hiromitsu Kiriyama
We report on the design and characterization of the plasma mirror system installed on the J-KAREN-P laser at the Kansai Photon Science Institute, National Institutes for Quantum Science and Technology. The reflectivity of the single plasma mirror system exceeded 80%. In addition, the temporal contrast was improved by two orders of magnitude at 1 ps before the main pulse. Furthermore, the laser near-field spatial distribution after the plasma mirror was kept constant at plasma mirror fluence of less than 100 kJ/cm2. We also present the results of investigating the difference and the fluctuation in energy, pulse width and pointing stability with and without the plasma mirror system.

5 March 2024 in High Power Laser Science and Engineering
Verified
Journal Article
Open access
PDF file
EVE. A. Vishnyakov
E. A. Vishnyakov
ASA. Sagisaka
A. Sagisaka
KOK. Ogura
K. Ogura
TET. Zh. Esirkepov
T. Zh. Esirkepov
BGB. Gonzalez-Izquierdo
B. Gonzalez-Izquierdo
APAlexander Pirozhkov
Alexander Pirozhkov
Tight focusing with very small f-numbers is necessary to achieve the highest at-focus irradiances. However, tight focusing imposes strong demands on precise target positioning in-focus to achieve the highest on-target irradiance. We describe several near-infrared, visible, ultraviolet and soft and hard X-ray diagnostics employed in a ∼1022 W/cm2 laser–plasma experiment. We used nearly 10 J total energy femtosecond laser pulses focused into an approximately 1.3-μm focal spot on 5–20 μm thick stainless-steel targets. We discuss the applicability of these diagnostics to determine the best in-focus target position with approximately 5 μm accuracy (i.e., around half of the short Rayleigh length) and show that several diagnostics (in particular, 3 $\omega$ reflection and on-axis hard X-rays) can ensure this accuracy. We demonstrated target positioning within several micrometers from the focus, ensuring over 80% of the ideal peak laser intensity on-target. Our approach is relatively fast (it requires 10–20 laser shots) and does not rely on the coincidence of low-power and high-power focal planes.

31 July 2020 in Crystals
Verified
Journal Article
Open access
PDF file
AKAkira Kon
Akira Kon
MNMamiko Nishiuchi
Mamiko Nishiuchi
Hiromitsu KiriyamaHiromitsu Kiriyama
Hiromitsu Kiriyama
MKMasaki Kando
Masaki Kando
SBStefan Bock
Stefan Bock
KKKiminori Kondo
Kiminori Kondo
In this study, a detailed investigation of the dynamics of the generation of pre-pulse by post-pulses is presented, using single-shot self-referenced spectral interferometry (SRSI). The capability of SRSI in terms of the single-shot measurement of the temporal contrast of high-power laser systems has been experimentally demonstrated. The results confirm that the energy levels of the pre-pulses increase proportional to the square of the B-integral parametrizing the nonlinearity of the amplifier chain.