Stefan Bock

Mr. Stefan Bock

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2022 in Nature Physics
Verified
Journal Article
Open access
PDF file
FKFlorian Kroll
Florian Kroll
FBFlorian-Emanuel Brack
Florian-Emanuel Brack
CBConstantin Bernert
Constantin Bernert
SBStefan Bock
Stefan Bock
EBElisabeth Bodenstein
Elisabeth Bodenstein
Elke BeyreutherElke Beyreuther
Elke Beyreuther
Recent oncological studies identified beneficial properties of radiation applied at ultrahigh dose rates, several orders of magnitude higher than the clinical standard of the order of Gy min–1. Sources capable of providing these ultrahigh dose rates are under investigation. Here we show that a stable, compact laser-driven proton source with energies greater than 60 MeV enables radiobiological in vivo studies. We performed a pilot irradiation study on human tumours in a mouse model, showing the concerted preparation of mice and laser accelerator, dose-controlled, tumour-conform irradiation using a laser-driven as well as a clinical reference proton source, and the radiobiological evaluation of irradiated and unirradiated mice for radiation-induced tumour growth delay. The prescribed homogeneous dose of 4 Gy was precisely delivered at the laser-driven source. The results demonstrate a complete laser-driven proton research platform for diverse user-specific small animal models, able to deliver tunable single-shot doses up to around 20 Gy to millimetre-scale volumes on nanosecond timescales, equivalent to around 109 Gy s–1, spatially homogenized and tailored to the sample. The platform provides a unique infrastructure for translational research with protons at ultrahigh dose rates.

5 December 2022 in Nature Photonics
Verified
Journal Article
Open access
PDF file
MLMarie Labat
Marie Labat
JCJurjen Couperus Cabadağ
Jurjen Couperus Cabadağ
AGAmin Ghaith
Amin Ghaith
AIArie Irman
Arie Irman
ABAnthony Berlioux
Anthony Berlioux
MCMarie Emmanuelle Couprie
Marie Emmanuelle Couprie
Free-electron lasers generate high-brilliance coherent radiation at wavelengths spanning from the infrared to the X-ray domains. The recent development of short-wavelength seeded free-electron lasers now allows for unprecedented levels of control on longitudinal coherence, opening new scientific avenues such as ultra-fast dynamics on complex systems and X-ray nonlinear optics. Although those devices rely on state-of-the-art large-scale accelerators, advancements on laser-plasma accelerators, which harness gigavolt-per-centimetre accelerating fields, showcase a promising technology as compact drivers for free-electron lasers. Using such footprint-reduced accelerators, exponential amplification of a shot-noise type of radiation in a self-amplified spontaneous emission configuration was recently achieved. However, employing this compact approach for the delivery of temporally coherent pulses in a controlled manner has remained a major challenge. Here we present the experimental demonstration of a laser-plasma accelerator-driven free-electron laser in a seeded configuration, where control over the radiation wavelength is accomplished. Furthermore, the appearance of interference fringes, resulting from the interaction between the phase-locked emitted radiation and the seed, confirms longitudinal coherence. Building on our scientific achievements, we anticipate a navigable pathway to extreme-ultraviolet wavelengths, paving the way towards smaller-scale free-electron lasers, unique tools for a multitude of applications in industry, laboratories and universities.

1 April 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TZTim Ziegler
Tim Ziegler
DAD. Albach
D. Albach
CBC. Bernert
C. Bernert
SBStefan Bock
Stefan Bock
FBF.-E. Brack
F.-E. Brack
KZK. Zeil
K. Zeil
We report on experimental investigations of proton acceleration from solid foils irradiated with PW-class laser-pulses, where highest proton cut-off energies were achieved for temporal pulse parameters that varied significantly from those of an ideally Fourier transform limited (FTL) pulse. Controlled spectral phase modulation of the driver laser by means of an acousto-optic programmable dispersive filter enabled us to manipulate the temporal shape of the last picoseconds around the main pulse and to study the effect on proton acceleration from thin foil targets. The results show that applying positive third order dispersion values to short pulses is favourable for proton acceleration and can lead to maximum energies of 70 MeV in target normal direction at 18 J laser energy for thin plastic foils, significantly enhancing the maximum energy compared to ideally compressed FTL pulses. The paper further proves the robustness and applicability of this enhancement effect for the use of different target materials and thicknesses as well as laser energy and temporal intensity contrast settings. We demonstrate that application relevant proton beam quality was reliably achieved over many months of operation with appropriate control of spectral phase and temporal contrast conditions using a state-of-the-art high-repetition rate PW laser system.

13 March 2023 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
NDNicholas P. Dover
Nicholas P. Dover
TZTim Ziegler
Tim Ziegler
SAStefan Assenbaum
Stefan Assenbaum
CBConstantin Bernert
Constantin Bernert
SBStefan Bock
Stefan Bock
MNMamiko Nishiuchi
Mamiko Nishiuchi
Laser-driven ion sources are a rapidly developing technology producing high energy, high peak current beams. Their suitability for applications, such as compact medical accelerators, motivates development of robust acceleration schemes using widely available repetitive ultraintense femtosecond lasers. These applications not only require high beam energy, but also place demanding requirements on the source stability and controllability. This can be seriously affected by the laser temporal contrast, precluding the replication of ion acceleration performance on independent laser systems with otherwise similar parameters. Here, we present the experimental generation of >60 MeV protons and >30 MeV u−1 carbon ions from sub-micrometre thickness Formvar foils irradiated with laser intensities >1021 Wcm2. Ions are accelerated by an extreme localised space charge field ≳30 TVm−1, over a million times higher than used in conventional accelerators. The field is formed by a rapid expulsion of electrons from the target bulk due to relativistically induced transparency, in which relativistic corrections to the refractive index enables laser transmission through normally opaque plasma. We replicate the mechanism on two different laser facilities and show that the optimum target thickness decreases with improved laser contrast due to reduced pre-expansion. Our demonstration that energetic ions can be accelerated by this mechanism at different contrast levels relaxes laser requirements and indicates interaction parameters for realising application-specific beam delivery.

31 August 2023 in Photonics
Verified
Journal Article
Open access
PDF file
Hiromitsu KiriyamaHiromitsu Kiriyama
Hiromitsu Kiriyama
Yasuhiro MIYASAKAYasuhiro MIYASAKA
Yasuhiro MIYASAKA
AKAkira Kon
Akira Kon
MNMamiko Nishiuchi
Mamiko Nishiuchi
ASAkito Sagisaka
Akito Sagisaka
USUlrich Schramm
Ulrich Schramm
We described the output performance and temporal quality enhancement of the J-KAREN-P petawatt laser facility. After wavefront correction using a deformable mirror, focusing with an f/1.3 off-axis parabolic mirror delivered a peak intensity of 1022 W/cm2 at 0.3 PW power levels. Technologies to improve the temporal contrast were investigated and tested. The origins of pre-pulses generated by post-pulses were identified and the elimination of most pre-pulses by removal of the post-pulses with wedged optics was achieved. A cascaded femtosecond optical parametric amplifier based on the utilization of the idler pulse rather than the signal pulse was developed for the complete elimination of the remaining pre-pulses. The orders of magnitude enhancement of the pedestal before the main pulse were obtained by using a higher surface quality of the convex mirror in the Öffner stretcher. A single plasma mirror was installed in the J-KAREN-P laser beam line for further contrast improvement of three orders of magnitude. The above developments indicate, although it has not been directly measured, the contrast can be as high as approximately 1015 up to 40 ps before the main pulse. We also showed an overview of the digital transformation (DX) of the system, enabling remote and automated operation of the J-KAREN-P laser facility.

30 January 2023 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
CBConstantin Bernert
Constantin Bernert
SAStefan Assenbaum
Stefan Assenbaum
SBStefan Bock
Stefan Bock
FBFlorian-Emanuel Brack
Florian-Emanuel Brack
TCThomas E. Cowan
Thomas E. Cowan
KZKarl Zeil
Karl Zeil
For high-intensity laser-solid interactions, the absolute density and surface density gradients of the target at the arrival of the ultrarelativistic laser peak are critical parameters. Accurate modeling of the leading edge-driven target preexpansion is desired to strengthen the predictive power of associated computer simulations. The transition from an initial solid state to a plasma state, i.e., the breakdown of the solid, defines the starting point of the subsequent target preexpansion. In this work, we report on the time-resolved observation of transient laser-induced breakdown (LIB) during the leading edge of high-intensity petawatt-class laser pulses with peak intensities of up to 5.7×1021W/cm2 in interaction with dielectric cryogenic hydrogen jet targets. LIB occurs much earlier than what is typically expected following the concept of barrier suppression ionization. The observation is explained by comparing a characterization study of target-specific LIB thresholds with laser contrast measurements. The results demonstrate the relevance of the laser pulse duration dependence of LIB for high-intensity laser-solid interactions. We provide an effective approach to determine the onset of LIB and thereby the starting point of target preexpansion in other laser-target systems.