Nurul Jamala

Nurul Jamala


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2023 in Journal of Daylighting
Verified
Journal Article
Open access
PDF file
NJNurul Jamala
Nurul Jamala
BHBaharuddin Hamzah
Baharuddin Hamzah
RMRosady Mulyadi
Rosady Mulyadi
ICIsty Cahyani
Isty Cahyani
Lighting control integrated with daylighting is recognized as an important and useful strategy in energy efficient building design. One of the right factors to reduce energy consumption for artificial lighting during the day is the maximum utilization of sunlight. The aim of this research, distribution of daylight into the building analysis with five models of building facades and value of illuminance in the morning, afternoon and evening with orientation of the window openings to the northeast and southwest. Bank Mega is one of the tall buildings in Makassar Indonesia, which is located in a coastal area that is not blocked by other tall buildings, so this building is the object of research as a basis for designing façade models on building envelopes. The methodology this study is quantitative, analyzing the performance of sunlight as a source of daylighting in office buildings. This paper presents field measurements in office buildings, namely in rooms that are oriented northeast and southwest. The analysis in the two spaces is a reference to determine the effect of sunlight on the orientation of the building. In this study also conducted visual perception experiments by submitting questionnaires to 43 respondents. the results show that there are some complaints for employees, because of the high illuminance value in certain areas. Furthermore, simulate using the Radiance Illuminance Program software to determine the illuminance value of room in the morning, noon and afternoon with five building facade model designs, i.e., massive glass, vertical, horizontal, diagonal, and vertical-diagonal model. The results presented in this paper show that the distribution of daylight in an east-oriented room is higher in the morning than in the evening and noon. Whereas in the southwest orientation it is inversely proportional, the value of light distribution is higher in the afternoon than in the morning and noon. Accordingly, orientation of the building affects distribution of daylight. The massive glass facade model without using sun shading has the highest light distribution value compared to other façade models, but can cause glare and excessive brightness. Furthermore, the second highest distribution of daylight with the vertical facade model, but there are also areas that exceed the standard illuminance level for workspaces, but only in areas near window openings. The combined model of the vertical-diagonal facade which also has a high distribution of illuminance value and to redirect daylight deep into building interior simultaneously in the morning, afternoon and evening. Accordingly, façade model on envelope of building affects distribution of daylight. The aesthetic value of architectural design shows that the appearance of the building does not look monotonous or massive, when using the building facade models because there are attractive areas in the building envelope. Header of solarlits.com

31 August 2024 in Journal of Daylighting
Verified
Journal Article
Open access
PDF file
BWBrilianty Wijaya
Brilianty Wijaya
NJNurul Jamala
Nurul Jamala
BHBaharuddin Hamzah
Baharuddin Hamzah
Passive lighting design plays an important role in providing natural lighting to save electricity consumption in buildings. This study aims to investigate the performance of natural lighting and the potential of alternative designs through sidelights with 3 shading device models and light shelves with different sizes in north, west, east, and south orientations. This research method is quantitative, which describes the measurement results in existing conditions and radiance illuminance software simulations. The results showed that at the beginning of field measurements, it was known that there were rooms with lighting intensity too high, too low, and uneven distribution. The simulation results use Radiance Illuminance software to determine the illuminance value of light distribution into space in the morning, afternoon, and evening. Improvised designs are applied with shading device models on the building envelope, namely horizontal, vertical, and egg-crate models in spaces oriented toward the East and West. This study also applied an interior-exterior light self-model measuring 50 cm, 100 cm, and 150 cm of space with the orientation of window openings towards the North and South. The simulation results in this study, show that without a shading device and using a horizontal model, there will be a decrease of 0.4% at a distance of 2 m from window openings oriented to the East, while to the West will be able to increase the illuminance value by 11.5% at a distance of 10.5 m from the window opening. Buildings without using light self and using interior-exterior light shelves measuring 50 cm can increase the illuminance value by 0.5% at a distance of 10.5 m from window openings in a space oriented towards the North, while the orientation towards the south, which can be increased the illuminance value by 0.4% at a distance of 6 m from the window opening. Based on this research analysis, it concluded that the best-improvised design in rooms oriented toward North and South is a 50 cm interior-exterior light shelf and horizontal shading device models are the best for spaces oriented to the East and West. This study, also concluded that the orientation of the building, the passive device model, and the distance of the measuring point in the building envelope, affect the intensity and distribution of daylight entering the building.

7 December 2023 in Nature: National Academic Journal of Architecture
Verified
Journal Article
Open access
PDF file
MIMuh. Aryanugraha Ismajaya
Muh. Aryanugraha Ismajaya
NJNurul Jamala
Nurul Jamala
AKAsniawaty Kusno
Asniawaty Kusno
Abstrak_ Penelitian ini mengoptimalkan peningkatan distribusi pencahayaan alami di Gedung Perpustakaan Universitas Islam Negeri Alauddin Makassar. Metode penelitian menggunakan pendekatan kuantitatif yang melibatkan pengukuran langsung pencahayaan alami dengan lux meter di lokasi serta penyebaran kuesioner kepada pengunjung perpustakaan. Data lapangan diolah menggunakan MS Office Excel untuk analisis pencahayaan, sedangkan aplikasi Autodesk Ecotect dengan plugin Dekstop Radiance digunakan untuk mensimulasikan hasil pengukuran lapangan. Simulasi dilakukan menggunakan 6 sampel model light shelf yang berbeda dalam upaya mengoptimalkan pencahayaan alami. Hasil menunjukkan bahwa penggunaan light shelf dengan posisi di tengah dan sudut miring pada bagian luar menjadi strategi terbaik dalam memaksimalkan cahaya alami yang masuk ke dalam gedung. Pada lantai 2, light shelf ditempatkan di tengah jendela dengan kemiringan 15° pada setiap bukaan jendela luar, yang menghasilkan nilai R2 tertinggi sebesar 0,94. Sedangkan pada lantai 3, penggunaan light shelf di tengah jendela dengan kemiringan 30° pada sisi utara dan 15° pada sisi selatan memperoleh nilai R2 tertinggi sebesar 0,85. Kata kunci: Pencahayaan Alami; Gedung Perpustakaan; Optimalisasi; Light Shelf; Efisiensi Energi;Ecotect Abstract_ This research aims to optimize natural lighting in the Alauddin Makassar State Islamic University Library building by enhancing the distribution of natural light. The study employs a quantitative method involving direct measurement of natural lighting using a lux meter on-site and the dissemination of questionnaires among library visitors. Field measurement data is processed using MS Office Excel to assess the lighting conditions. Additionally, the application of Autodesk Ecotect with the Desktop Radiance plugin is utilized to simulate field measurement outcomes. To optimize natural lighting, simulations are conducted using six different models of light shelves. The simulation results indicate that employing a light shelf positioned centrally with an external angled surface proves most effective in maximizing natural light entry into the building. On the second floor, a centrally positioned light shelf with a 15° angle on each outer window opening yields the highest R2 value of 0.94. Meanwhile, on the third floor, using a centrally positioned light shelf with a 30° angle on the north side and 15° on the south side of the window achieves the highest R2 value of 0.85.. Keywords:  Natural Lighting, Library Building, Optimization, Light Shelf, Energy Efficiency, Ecotect