Mehdi Othman

Mr. Mehdi Othman


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2018 in Sensor Review
Verified
Journal Article
Closed access
RFRabeb Faleh
Rabeb Faleh
SGSami Gomri
Sami Gomri
MOMehdi Othman
Mehdi Othman
KAKhalifa Aguir
Khalifa Aguir
AKAbdennaceur Kachouri
Abdennaceur Kachouri
Purpose: In this paper, a novel hybrid approach aimed at solving the problem of cross-selectivity of gases in electronic nose (E-nose) using the combination classifiers of support vector machine (SVM) and k-nearest neighbors (KNN) methods was proposed. Design/methodology/approach: First, three WO3 sensors E-nose system was used for data acquisition to detect three gases, namely, ozone, ethanol and acetone. Then, two transient parameters, derivate and integral, were extracted for each gas response. Next, the principal component analysis (PCA) was been applied to extract the most relevant sensor data and dimensionality reduction. The new coordinates calculated by PCA were used as inputs for classification by the SVM method. Finally, the classification achieved by the KNN method was carried out to calculate only the support vectors (SVs), not all the data. Findings: This work has proved that the proposed fusion method led to the highest classification rate (100 per cent) compared to the accuracy of the individual classifiers: KNN, SVM-linear, SVM-RBF, SVM-polynomial that present, respectively, 89, 75.2, 80 and 79.9 per cent as classification rate. Originality/value: The authors propose a fusion classifier approach to improve the classification rate. In this method, the extracted features are projected into the PCA subspace to reduce the dimensionality. Then, the obtained principal components are introduced to the SVM classifier and calculated SVs which will be used in the KNN method.

28 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
MOMehdi Othman
Mehdi Othman
CTChristophe Théron
Christophe Théron
MBMarc BENDAHAN
Marc BENDAHAN
CRCharles Rivron
Charles Rivron
Sandrine BernardiniSandrine Bernardini
Sandrine Bernardini
TTThu-Hoa Tran-Thi
Thu-Hoa Tran-Thi
The present study evaluates the ozone (O3) and nitrogen dioxide (NO2) removal performance of specific filters based on nanoporous materials. These materials, produced via the sol-gel process with functionalized silicon alkoxides as precursors, are tailored for O3 trapping. The gas removal effectiveness of the filters was assessed through measurements of O3 concentrations in the air upstream and downstream of the filters. Depending on the filter nature, O3 can be totally trapped while NO2 can pass over a specific concentration range.