Marc BENDAHAN

Prof. Marc BENDAHAN


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2021 in Applied Intelligence
Verified
Journal Article
Closed access
PDF file
Mohand DjeziriMohand Djeziri
Mohand Djeziri
ODOussama Djedidi
Oussama Djedidi
NMNicolas Morati
Nicolas Morati
JSJean-Luc Seguin
Jean-Luc Seguin
MBMarc BENDAHAN
Marc BENDAHAN
TCThierry Contaret
Thierry Contaret

15 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
FAFatima Ezahra Annanouch
Fatima Ezahra Annanouch
VMVirginie Martini
Virginie Martini
TFTomas Fiorido
Tomas Fiorido
BLBruno Lawson
Bruno Lawson
KAKhalifa Aguir
Khalifa Aguir
MBMarc BENDAHAN
Marc BENDAHAN
In this paper, we report the fabrication and characterization of a portable transdermal alcohol sensing device via a human finger, using tin dioxide (SnO2) chemoresistive gas sensors. Compared to conventional detectors, this non-invasive technique allowed us the continuous monitoring of alcohol with low cost and simple fabrication process. The sensing layers used in this work were fabricated by using the reactive radio frequency (RF) magnetron sputtering technique. Their structure and morphology were investigated by means of X-ray spectroscopy (XRD) and scanning electron microscopy (SEM), respectively. The results indicated that the annealing time has an important impact on the sensor sensitivity. Before performing the transdermal measurements, the sensors were exposed to a wide range of ethanol concentrations and the results displayed good responses with high sensitivity, stability, and a rapid detection time. Moreover, against high relative humidity (50% and 70%), the sensors remained resistant by showing a slight change in their gas sensing performances. A volunteer (an adult researcher from our volunteer group) drank 50 mL of tequila in order to realize the transdermal alcohol monitoring. Fifteen minutes later, the volunteer’s skin started to evacuate alcohol and the sensor resistance began to decline. Simultaneously, breath alcohol measurements were attained using a DRAGER 6820 certified breathalyzer. The results demonstrated a clear correlation between the alcohol concentration in the blood, breath, and via perspiration, which validated the embedded transdermal alcohol device reported in this work.

11 February 2021 in Processes
Verified
Journal Article
Open access
PDF file
Mohand DjeziriMohand Djeziri
Mohand Djeziri
ODOussama Djedidi
Oussama Djedidi
Samir BENMOUSSASamir BENMOUSSA
Samir BENMOUSSA
MBMarc BENDAHAN
Marc BENDAHAN
JSJean-Luc Seguin
Jean-Luc Seguin
Fuel cells are key elements in the transition to clean energy thanks to their neutral carbon footprint, as well as their great capacity for the generation of electrical energy by oxidizing hydrogen. However, these cells operate under straining conditions of temperature and humidity that favor degradation processes. Furthermore, the presence of hydrogen—a highly flammable gas—renders the assessment of their degradations and failures crucial to the safety of their use. This paper deals with the combination of physical knowledge and data analysis for the identification of health indices (HIs) that carry information on the degradation process of fuel cells. Then, a failure prognosis method is achieved through the trend modeling of the identified HI using a data-driven and updatable state model. Finally, the remaining useful life is predicted through the calculation of the times of crossing of the predicted HI and the failure threshold. The trend model is updated when the estimation error between the predicted and measured values of the HI surpasses a predefined threshold to guarantee the adaptation of the prediction to changes in the operating conditions of the system. The effectiveness of the proposed approach is demonstrated by evaluating the obtained experimental results with prognosis performance analysis techniques.

13 April 2024 in Microsystem Technologies
Verified
Journal Article
Closed access
PDF file
Mohand DjeziriMohand Djeziri
Mohand Djeziri
Samir BENMOUSSASamir BENMOUSSA
Samir BENMOUSSA
MBMarc BENDAHAN
Marc BENDAHAN
JSJean-Luc Seguin
Jean-Luc Seguin

30 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
FAFatima Ezahra Annanouch
Fatima Ezahra Annanouch
GBGilles Bouchet
Gilles Bouchet
Pierre PerrierPierre Perrier
Pierre Perrier
NMNicolas Morati
Nicolas Morati
CRChristelle Reynard-Carette
Christelle Reynard-Carette
MBMarc BENDAHAN
Marc BENDAHAN
In this paper, we report the significant role played by the testing chamber for measuring the true gas sensor responses. Two different designs were studied and compared. The first one has a cross-shape in which the direction of gas flow is perpendicular to the sensor surface. The second one has a boat-shape in which the gas flow is tangential to the sensor surface. The results demonstrated that contrarily to the cross-shape chamber, the gas concentration is highly homogenous and equal to the set point in the boat-shape chamber. Additionally, the sensor responses are much stable, faster and higher. Besides, all the mathematical modeling and simulation results are in a good agreement with the experimental studies, which allow the validation of the proposed boat-shape chamber model.

11 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
Sandrine BernardiniSandrine Bernardini
Sandrine Bernardini
MBMohamed Hameda Benchekroun
Mohamed Hameda Benchekroun
TFTomas Fiorido
Tomas Fiorido
KAKhalifa Aguir
Khalifa Aguir
MBMarc BENDAHAN
Marc BENDAHAN
CVChristine Videlot-Ackermann
Christine Videlot-Ackermann
We focus on ozone (O3) detection at ambient temperature by Zinc Oxide (ZnO) nanoparticles (NPs) deposited on Si/SiO2 by spin coating from colloidal solutions as sensitive layers for air quality monitoring. We establish that at room temperature using continuous Ultra-Violet (UV) light irradiation enhances the sensing responses. Three annealing temperatures of ZnO films were performed to compare the sensing properties. These sensors present repeatable responses towards O3 with fast responses for concentrations as low as 35 ppb with processes compatible with most of flexible substrates.